JTCS St. Jude Medical
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brodman, R.
Right arrow Articles by Furman, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brodman, R.
Right arrow Articles by Furman, S.

The Journal of Thoracic and Cardiovascular Surgery, Vol 103, 649-654, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Removal of infected transvenous leads requiring cardiopulmonary bypass or inflow occlusion

R Brodman, R Frame, C Andrews and S Furman
Department of Cardiothoracic Surgery, Montefiore Medical Center, Bronx, N.Y. 10467.

Infection, although uncommon, can be the most lethal of all potential complications after transvenous pacemaker implantation. The infection rate at our institution has been 0.56% (42 implants) during the preceding 17 years for 7435 transvenous pacemakers implanted in 4333 patients. Four of the 42 patients required use of cardiopulmonary bypass or inflow occlusion to remove the infected transvenous leads. Seven patients had their pacemakers implanted elsewhere and were transferred to our medical center for treatment. One patient died postoperatively because of persistent sepsis from a retained lead segment. All other patients survived, and none had recurrent infection. We recommend removal of all hardware if there is infection of the pacemaker system. If traction or other methods fail to remove the transvenous portion of the pacemaker system, open methods of removal, although rarely required, are safe and effective and should be used without delay.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
V. Rohn, M. Slais, T. Kotulak, and M. Psenicka
Pulmonary valve replacement for pacing electrodes related bacterial endocarditis.
Ann. Thorac. Surg., June 1, 2008; 85(6): 2128 - 2130.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-P. Chang, M.-C. Chen, G. B.-F. Guo, and C.-L. Kao
Less-Invasive Surgical Extraction of Problematic or Infected Permanent Transvenous Pacemaker System
Ann. Thorac. Surg., April 1, 2005; 79(4): 1250 - 1254.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F.A.L.E. Bracke, A Meijer, and L.M. van Gelder
Lead extraction for device related infections: a single-centre experience
Europace, January 1, 2004; 6(3): 243 - 247.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. R. Moon, C. J. Camillo, and M. J. Gleva
Laser-assist during extraction of chronically implanted pacemaker and defibrillator leads
Ann. Thorac. Surg., June 1, 2002; 73(6): 1893 - 1896.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
R. A. Memon, J. Buckley, and A. O'Donnell
Percutaneous Extraction of Entrapped Infective Transvenous Pacing Lead
Asian Cardiovasc Thorac Ann, March 1, 2002; 10(1): 69 - 71.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Miralles, V. Moncada, H. Chevez, R. Rodriguez, J. Granados, and E. Castells
Pacemaker endocarditis: approach for lead extraction in endocarditis with large vegetations
Ann. Thorac. Surg., December 1, 2001; 72(6): 2130 - 2132.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
F A Bracke, A Meijer, and L M van Gelder
Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?
Heart, March 1, 2001; 85(3): 254 - 259.
[Full Text]


Home page
ANGIOLOGYHome page
M. K. Batur, E. Akgul, and K. Ovunc
Permanent Left Ventricular Pacing from the Great Cardiac Vein of a Patient with Artificial Tricuspid and Mitral Valves: A Case Report
Angiology, December 1, 2000; 51(12): 1027 - 1030.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. J. Wilhelm, C. Schmid, D. Hammel, S. Kerber, H. M. Loick, M. Herrmann, and H. H. Scheld
Cardiac Pacemaker Infection: Surgical Management With and Without Extracorporeal Circulation
Ann. Thorac. Surg., December 1, 1997; 64(6): 1707 - 1712.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Aldrete and G. E. Miller
Removal of infected transvenous pacemakers
J. Thorac. Cardiovasc. Surg., April 1, 1994; 107(4): 1164 - 1165.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.