JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kawachi, Y.
Right arrow Articles by Tokunaga, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kawachi, Y.
Right arrow Articles by Tokunaga, K.

The Journal of Thoracic and Cardiovascular Surgery, Vol 104, 5-13, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

More than ten years' follow-up of the Hancock porcine bioprosthesis in Japan

Y Kawachi, J Tanaka, R Tominaga, K Kinoshita and K Tokunaga
Division of Cardiovascular Surgery, Faculty of Medicine, Kyushu University, Fukuoka, Japan.

From February 1975 through October 1981, 256 Hancock porcine bioprostheses (Johnson & Johnson Cardiovascular, King of Prussia, Pa.) (60 aortic, 169 mitral, and 27 pulmonary/tricuspid position) were implanted in 220 patients (104 male and 116 female, aged 9 to 67 years; mean 43.3) at Kyushu University Hospital in Japan. The procedures include 41 aortic valve replacements, 121 mitral valve replacements, 4 pulmonary valve replacements, 6 tricuspid valve replacements, and 48 combined valve replacements (31 aortic plus mitral, 13 mitral plus tricuspid, and 4 aortic plus mitral plus tricuspid). Hospital mortality was 6.4%. Follow-up was 98% during 8 to 14 (mean 10.5) years. Cumulative follow-up was 1836 patient-years and 2078 valve-years. At 10 years the overall actuarial survival rate, including hospital morality, was 70% +/- 3%, and freedom from valve-related mortality with sudden death was 87% +/- 3%. More than half of the current survivors required no anticoagulant therapy. Freedom from thromboembolism or anticoagulant- related hemorrhage (or both) and prosthetic valve endocarditis was common. Freedom from structural valve failure and reoperation declined more than 9 years after replacement of left-sided heart valves but not after replacement of right-sided heart valves. Sixty-seven patients underwent 68 repeat operations, and there were four deaths (5.9%). The rate of freedom from overall valve-related complications at 10 years was 62% +/- 8% for aortic valve replacement, 53% +/- 5% for mitral valve replacement, 80% +/- 13% for pulmonary/tricuspid valve replacement, and 42% +/- 9% for combined valve replacement. There was a significant difference between pulmonary/tricuspid valve replacement and combined valve replacement (p less than 0.05). The Hancock bioprosthesis is suitable for the replacement of valves in the right side of the heart but not for combined valve replacement.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
B.-C. Chang, S.-H. Lim, G. Yi, Y. S. Hong, S. Lee, K.-J. Yoo, M. S. Kang, and B. K. Cho
Long-Term Clinical Results of Tricuspid Valve Replacement
Ann. Thorac. Surg., April 1, 2006; 81(4): 1317 - 1324.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Silberman and B. S. Goldman
Premature leaflet dysfunction in a tricuspid bioprosthesis
J. Thorac. Cardiovasc. Surg., June 1, 1994; 107(6): 1542 - 1543.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.