JTCS St. Jude Medical
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bellotto, F.
Right arrow Articles by Weintraub, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bellotto, F.
Right arrow Articles by Weintraub, R. M.

The Journal of Thoracic and Cardiovascular Surgery, Vol 104, 561-568, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Mechanical assistance of the left ventricle: acute effect on cardiac performance and coronary flow of different perfusion patterns

F Bellotto, RG Johnson, J Watanabe, MJ Levine, A Franklin and RM Weintraub
Division of Cardiothoracic Surgery, Beth Israel Hospital, Harvard Medical School, Boston, Mass.

Mechanical circulatory assistance by ventricular assist devices provides an opportunity to influence the aortic pressure pattern, which may affect ventricular loading and coronary perfusion. The effect of synchronous, pulsatile coronary perfusion of an assist device-supported left ventricle has not been studied. To analyze the effect of different perfusion patterns on left ventricular performance and on coronary flow, independent of pressure and volume loading, we used three different modes of aortic perfusion in an isometric, contracting, isolated canine heart model. The effect of nonpulsatile, counter- pulsatile, and copulsatile coronary perfusion was analyzed in four subgroups to simulate different, clinically relevant situations (using two different ventricular end-diastolic volumes [normal and high] and two mean perfusion pressures [normal and critically low]). Our experiments demonstrated that total coronary flow is optimized by making the perfusion pressure pulsatile and by synchronously timing the pump systole with ventricular diastole (counterpulsation). Under identical conditions of preload and mean perfusion pressure, coronary flow and left ventricular contractility were decreased during non- pulsatile and copulsatile aortic perfusion when compared with counterpulsatile flow. There were no significant differences between the nonpulsatile and copulsatile modes. We conclude from these data that a nonejecting, but contracting, left ventricle will have improved systolic function and coronary blood flow if the coronary perfusion pressure is synchronized in a counterpulsatile manner. This is a significant implication for mechanical left ventricular assist devices when used to promote myocardial recovery.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T. Tedoriya, M. Kawasuji, N. Sakakibara, H. Takemura, Y. Watanabe, and R. Hetzer
Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device
Ann. Thorac. Surg., August 1, 1998; 66(2): 477 - 481.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. Konertz, H. Hotz, M. Schneider, M. Redlin, and H. Reul
Clinical Experience With the MEDOS HIA-VAD System in Infants and Children: A Preliminary Report
Ann. Thorac. Surg., April 1, 1997; 63(4): 1138 - 1144.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.