JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tamari, Y.
Right arrow Articles by Tortolani, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tamari, Y.
Right arrow Articles by Tortolani, A. J.

The Journal of Thoracic and Cardiovascular Surgery, Vol 106, 997-1007, Copyright © 1993 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump

Y Tamari, K Lee-Sensiba, EF Leonard, V Parnell and AJ Tortolani
Department of Surgery, North Shore University Hospital-Cornell University Medical College, Manhasset, N.Y. 11030.

Two Bio-Medicus BP-50 centrifugal pumps and two roller pumps were tested simultaneously with porcine blood at 21 degrees +/- 1 degree C in four in vitro circuits to determine the effect of four combinations of flow and pressure conditions on blood damage. Flows of 300 ml/min (1/4-inch inner-diameter tubing in the roller pump) and 1775 ml/min (1/2-inch inner-diameter tubing in the roller pump) and pressure differences across the pump (delta P = outlet pressure--inlet pressure) of 215 mm Hg (n = 6) and 345 mm Hg (n = 5) were examined. The index of hemolysis (milligrams plasma hemoglobin per 100 L blood pumped) for the BP-50 pump was higher at a flow of 300 ml/min than at a flow of 1775 ml/min (p < 0.0002). At 300 ml/min, the index of hemolysis for the BP- 50 pump tended to be higher at 345 mm Hg than at 215 mm Hg (mean +/- standard error of the mean, 135 +/- 22 versus 88 +/- 9, p = 0.059). At 1775 ml/min, there was no difference in the index of hemolysis for the BP-50 pump between 215 and 345 mm Hg (37 +/- 7 versus 29 +/- 5, p = 0.32). With the roller pump, the index of hemolysis was higher at a flow of 300 ml/min than at a flow of 1775 ml/min (p < 0.036), but there was no difference in the indexes of hemolysis between 215 and 345 mm Hg at 300 ml/min (60 +/- 9 versus 61 +/- 11, p = 0.93) or at 1775 ml/min (40 +/- 6 versus 36 +/- 6, p = 0.61). Comparison between the two types of pumps showed that the index of hemolysis was significantly higher for the BP-50 than for the roller pump at a flow of 300 ml/min and a delta P of 215 mm Hg (88 +/- 9 versus 60 +/- 9, p = 0.009), as well as at a flow of 300 ml/min and a delta P of 345 mm Hg (135 +/- 22 versus 61 +/- 11, p = 0.001). At a flow of 1775 ml/min, there was no difference in the index of hemolysis between the two pumps at either pressure condition.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: Perfusion System
Card. Surg. Adult, January 1, 2008; 3(2008): 350 - 370.
[Full Text]


Home page
Card Surg AdultHome page
E. A. Hessel II and L. H. Edmunds Jr.
Extracorporeal Circulation: Perfusion Systems
Card. Surg. Adult, January 1, 2003; 2(2003): 317 - 338.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
I.S. Morgan, M. Codispoti, K. Sanger, and P.S. Mankad
Superiority of centrifugal pump over roller pump in paediatric cardiac surgery: prospective randomised trial
Eur. J. Cardiothorac. Surg., May 1, 1999; 13(5): 526 - 532.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
L B Mongero, J R Beck, T W Orr, R M Kroslowitz, K Lee-Sensiba, and M C Oz
Clinical evaluation of setting pump occlusion by the dynamic method: effect on flow
Perfusion, September 1, 1998; 13(5): 360 - 368.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1993 by The American Association for Thoracic Surgery.