J Thorac Cardiovasc Surg 1996;111:1194-1199
© 1996 Mosby, Inc.
SURGERY FOR ACQUIRED HEART DISEASE |
Supported in part by Valleylab, Inc., Boulder, Colo.
Received for publication June 10, 1994 Accepted for publication July 26, 1995. Address for reprints: H. Thurston, MD, FRCP, Department of Medicine and Therapeutics, Clinical Sciences Building, P.O. Box 65, Leicester LE2 7LX, England, United Kingdom
Abstract
The most common technique currently employed to harvest the internal thoracic artery for coronary artery bypass grafting is conventional electrocautery. This study compared an alternative method, electrocautery with an ultrasonic aspirator, for harvesting the internal thoracic artery. Patients were randomly assigned to one of six experimental groups (conventional electrocautery, ultrasonic aspirator at settings of 60%, 80%, and 100% power output, and ultrasonic aspirator in 100% CAVI-Pulse modes 1 and 3). Ring segments of internal thoracic artery were studied in an organ bath. Contraction responses were elicited with 123 mmol/L potassium physiologic salt solution, KPSS, KPSS solution containing noradrenaline, and a cumulative noradrenaline dose-contraction curve. Relaxation studies were performed with the vasodilators acetylcholine, bradykinin, and sodium nitroprusside. Forty percent of the electrocauterized vessels were traumatized or damaged and failed to respond to contractile stimuli, whereas only 10% of the vessels in ultrasonic aspirator groups 60%, 80%, and 100% failed to respond. All vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 1 responded, whereas 20% of the vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 3 failed to respond. All settings of electrocautery with an ultrasonic aspirator produced a greater contractile response to KPSS and noradrenaline. Acetylcholine and sodium nitroprusside produced similar relaxations in all groups, but the bradykinin responses were significantly improved in all groups undergoing 100% electrocautery with an ultrasonic aspirator. These results suggest that 100% electrocautery with an ultrasonic aspirator, particularly in 100% CAVI-Pulse mode 1, resulted in less damage and trauma than conventional electrocautery during harvesting of the internal thoracic artery. (J THORACCARDIOVASCSURG1996;111:1194-9)
This article has been cited by other articles:
![]() |
T. A. Vassiliades Jr, N. Cosgriff, A. Denham, J. Olson, and D. H. Maul Superiority of Using Bipolar Radiofrequency Energy for Internal Mammary Artery Harvesting Ann. Thorac. Surg., April 1, 2007; 83(4): 1508 - 1512. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Jeanmart, L. P. Perrault, N. Desjardins, O. Chavanon, M. Carrier, and J. D. Fonger Arterial balloon catheter: a new atraumatic device for dilating arterial grafts Ann. Thorac. Surg., September 1, 2001; 72(3): 810 - 815. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Ghosh Ultrasonic Devices in Cardiac Surgery Asian Cardiovasc Thorac Ann, December 1, 1999; 7(4): 333 - 338. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Coulson, S. A. Bakhshay, P. Spohn, and M. Borges Truly minimally invasive coronary artery bypass: The TRUCAB J. Thorac. Cardiovasc. Surg., July 1, 1998; 116(1): 181 - 181. [Full Text] |
||||
![]() |
M. E. Lee Carbodissection of the internal thoracic artery pedicle J. Thorac. Cardiovasc. Surg., March 1, 1997; 113(3): 621 - 622. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |