JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Duncan, A. C.
Right arrow Articles by Vesely, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Duncan, A. C.
Right arrow Articles by Vesely, I.

J Thorac Cardiovasc Surg 1997;113:302-310
© 1997 Mosby, Inc.


SURGERY FOR ACQUIRED HEART DISEASE

VISCOELASTICITY OF DYNAMICALLY FIXED BIOPROSTHETIC VALVES. II. EFFECT OF GLUTARALDEHYDE CONCENTRATION

Anthony C. Duncan, PhDa, Derek Boughner, PhD, MDa, Ivan Vesely, PhDb

Supported in part by a grant from the Medical Research Council of Canada (MRC). Dr Anthony C. Duncan was supported by a postdoctoral fellowship from the MRC, Dr. D. Boughner is a Research Associate at the Heart and Stroke Foundation of Ontario, Canada, and Dr. I. Vesely is a Research Scholar of the Foundation.

Received for publication April 2, 1996 revisions requested May 22, 1996; revisions received Sept. 27, 1996 accepted for publication Oct. 8, 1996. Address for reprints: Anthony C. Duncan, J. P. Robarts Research Institute, 100 Perth Dr., PO Box 5015, London, Ontario, N6A 5K8 Canada.

Abstract

Objectives: We have previously shown the benefits of dynamic fixation over conventional static fixation of bioprosthetic valves. In an attempt to increase the durability of bioprosthetic heart valves, we explored the benefit of low-concentration glutaraldehyde dynamic fixation.Methods: Pig aortic valves obtained fresh from the abattoir and excised with the entire root were dynamically fixed in glutaraldehyde phosphate buffer solutions varying in concentration from 0.05% to 2.5%. Denaturation temperatures were measured and mechanical testing was performed at low (3 mm/sec) to high physiologic rates (30 mm/sec) at 37° C in isotonic modified Hanks solution.Results: When fixed dynamically in 0.05% glutaraldehyde solution for 24 hours, the tissue reached a degree of cross-linking (denaturation temperature = 82.8° ± 0.6° C) significantly higher than that obtained for 0.05% static fixation (denaturation temperature = 79.3° ± 0.9° C) (p < 0.05) but similar to that for conventional static fixation in 0.5% glutaraldehyde solution (denaturation temperature = 83.5° ± 0.3° C). After fixation in low-concentration glutaraldehyde (0.05%), final relaxation slopes and moduli in the circumferential direction were significantly higher than those for the statically fixed tissue but similar to those for the fresh tissue. However, both dynamic and static fixation had the effect of increasing tissue extensibility to similar extents in both directions, irrespective of glutaraldehyde concentration.Conclusion: Dynamic glutaraldehyde fixation of a porcine aortic valve at lower concentrations resulted in a better degree of cross-linking and a material with biomechanical properties that more closely mimic those of natural heart valve tissue. (J thorac Cardiovasc Surg 1997;113:302-10)




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
W. Li, W.-Y. Liu, D.-H. Yi, S.-Q. Yu, and Z.-X. Jin
Histological/Biological Characterization of Decellularized Bovine Jugular Vein
Asian Cardiovasc Thorac Ann, April 1, 2007; 15(2): 91 - 96.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
J. M. G. Paez, A. C. Sanmartin, E. J. Herrero, I. Millan, A. Cordon, A. Rocha, M. A. Maestro, G. Tellez, and J. L. Castillo-Olivares
Resistance and Stability of A New Method for Bonding Biological Materials Using Sutures and Biological Adhesives
J Biomater Appl, January 1, 2005; 19(3): 215 - 236.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
J. M. G. Paez, E.J. Herrero, A. Rocha, M. Maestro, J. L. Castillo-Olivares, I. Millan, A. C. Sanmartin, and A. Cordon
Resistance to Tensile Stress of a Bioadhesive Utilized for Medical Purposes: Loctite 4011
J Biomater Appl, January 1, 2004; 18(3): 179 - 192.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
J. M. G. Paez, E. J. Herrero, A. Rocha, M. Martin-Maestro, J. L. Castillo-Olivares, I. Millan, A. C. Sanmartin, and A. Cordon
The Telescoping Suture -Part 1: Does this Technique Improve the Mechanical Behavior of a Biomaterial?: Calf Pericardium
J Biomater Appl, October 1, 2002; 17(2): 85 - 103.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
J. M. G. Paez and E. Jorge-Herrero
Assessment of Pericardium in Cardiac Bioprostheses: A Review
J Biomater Appl, April 1, 1999; 13(4): 351 - 388.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Chanda, R. Kuribayashi, and T. Abe
Concentration of glutaraldehyde in fixation of bioprosthetic values
J. Thorac. Cardiovasc. Surg., September 1, 1997; 114(3): 512 - 512.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The American Association for Thoracic Surgery.