|
|
||||||||
J Thorac Cardiovasc Surg 1998;115:1111-1115
© 1998 Mosby, Inc.
SURGERY FOR ACQUIRED HEART DISEASE |
From the Section of Pediatric Cardiology and Cardiovascular Surgery, Veterans General Hospital, Taipei, the Department of Chemical Engineering, National Central University, and the Department of Pathology, Pig Research Institute, Taipei, Taiwan.
Received for publication Dec. 24, 1996. Revisions requested April 15, 1997; revisions received Sept. 24, 1997. Accepted for publication Sept. 30, 1997. Address for reprints: Jen-Her Lu, MD, Section of Pediatric Cardiology, Veterans General Hospital, Taipei, Taiwan.
Abstract
Objective: Primary concerns about currently available pericardial substitutes include adhesion and epicardial reaction. The purpose of this study is to evaluate host reaction to pericardial substitutes with and without incorporating slow heparin release.
Methods: To avoid biologic variation among these pericardial patches, we made a composite of six membranes. The composite membrane consisted of epoxy-fixed patches with (1) or without (2) ionically bound heparin, a glutaraldehyde-fixed patch with (3) or without (4) ionically bound heparin, an expanded polytetrafluoroethylene patch (5), and a polyester polymeric patch (6). Ten recipient dogs weighing from 12 to 19 kg (mean 13.6 kg) were used to assess the composite membranes as pericardial substitutes. The implanted composite membranes were retrieved 1 week (one dog), 2 weeks (one dog), 4 weeks (one dog), 8 weeks (one dog), and 12 weeks (six dogs) after implantation.
Results: Overall, the synthetic patches had a more notable inflammatory reaction than the biologic patches with or without ionically bound heparin. The heparin-bound patches caused significantly less inflammation than their nonheparinized counterparts. The heparinized porcine patches cross-linked with different compounds were found to have less fibrous formation than the nonheparinized patches and the synthetic patches.
Conclusions: Heparinized pericardial substitutes may cause less adhesion and inflammatory reaction than nonheparinized material.
This article has been cited by other articles:
![]() |
I. Yoshioka, Y. Saiki, K. Sakuma, A. Iguchi, T. Moriya, Y. Ikada, and K. Tabayashi Bioabsorbable Gelatin Sheets Latticed With Polyglycolic Acid Can Eliminate Pericardial Adhesion Ann. Thorac. Surg., September 1, 2007; 84(3): 864 - 870. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Masuda, Y. Saiki, S. Kawatsu, I. Yoshioka, H. Fujiwara, S. Kawamoto, S. Sai, A. Iguchi, N. Sakamoto, T. Ohashi, et al. Trial of new vascular clips for aortic anastomosis in a canine model J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 723 - 730. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Sakuma, A. Iguchi, Y. Ikada, and K. Tabayashi Closure of the Pericardium Using Synthetic Bioabsorbable Polymers Ann. Thorac. Surg., November 1, 2005; 80(5): 1835 - 1840. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Kajihara, M. Eto, Y. Oishi, N. Boku, K. Kuwahara, N. Nishiguchi, C. Kotani, and S. Morita Three-layered synthetic pericardial substitutes reduce postoperative pericardial adhesions J. Thorac. Cardiovasc. Surg., January 1, 2005; 129(1): 18 - 24. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Saha, W. McEwan, F. A Frizelle, and H. Singh Limiting Pericardial Adhesions after Coronary Artery Bypass: Experimental Study Asian Cardiovasc Thorac Ann, March 1, 2004; 12(1): 61 - 64. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Harada, T. Ida, T. Koyanagi, K. Kasahara, F. Naganuma, and S. Hosoda Pseudoaneurysm of the Saphenous Vein Graft Related to Artificial Rubber Pericardium: A Case Report Angiology, November 1, 2002; 53(6): 741 - 743. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |