JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Zsolt L. Nagy
Kevin G. Watterson
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nagy, Z. L.
Right arrow Articles by Watterson, K. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nagy, Z. L.
Right arrow Articles by Watterson, K. G.

J Thorac Cardiovasc Surg 1999;117:92-98
© 1999 Mosby, Inc.


SURGERY FOR ADULT CARDIOVASCULAR DISEASE

THE EFFECT OF SIZING ON THE IN VITRO HYDRODYNAMIC CHARACTERISTICS AND LEAFLET MOTION OF THE TORONTO SPV* STENTLESS VALVE

Zsolt L. Nagy, Dra, John Fisher, PhDb, Peter G. Walker, PhDb, Kevin G. Watterson, FRACSa

From the Yorkshire Heart Centrea and the School of Mechanical Engineering,b University of Leeds, Leeds, United Kingdom.

*Toronto SPV is a trademark of St Jude Medical, Inc (St Paul, Minn).

Received for publication May 15, 1998. Revisions requested June 25, 1998. Revisions received Aug 4, 1998. Accepted for publication Aug 10, 1998. Address for reprints: K. G. Watterson, FRACS, Yorkshire Heart Centre, Calverley St, Leeds LS1 3EX, United Kingdom.

Objectives:We established an in vitro model to investigate the effects of valve sizing on the hemodynamic characteristics and leaflet motion of the Toronto SPV valve (St Jude Medical, Inc, St Paul, Minn).
Methods: Nine valves were first implanted in fresh porcine aortic roots and then retested in glutaraldehyde-treated porcine aortic roots. Three valves were 1- to 2-mm oversized, 3 were 1- to 2-mm undersized, and there were 3 size-for-size implantations. The elasticities of the aortic roots and the composite roots were measured in the pressure range between 0 and 120 mm Hg, and the composite roots were then tested in a pulsatile flow simulator. The transvalvular gradient and regurgitation were measured and the effective orifice area and performance index were calculated for each root. Leaflet motion was recorded on videotape.
Results: The external diameter of the fresh root increased by 35% as the hydrostatic pressure rose from 0 to 120 mm Hg, as compared with 11% for the glutaraldehyde-treated root. Valve implantation in the fresh root reduced the distensibility to 22% but did not change distensibility in the glutaraldehyde-treated root. The effective orifice area was dependent on the valve size, with the transvalvular gradient decreasing as the valve size increased. For the same size of valve the hydrodynamic parameters were slightly better if the valve was undersized by 1 mm. A significant difference in favor of the undersized valves was found in open-leaflet bending deformation.
Conclusion: Leaflet motion of the stentless porcine aortic valve in vitro is improved if the valve is slightly undersized, and this may be beneficial to the long-term durability of the prosthesis.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. P. Urbanski, A. Diegeler, A. Siebel, M. Zacher, and R. W. Hacker
Valved stentless composite graft: clinical outcomes and hemodynamic characteristics
Ann. Thorac. Surg., February 1, 2003; 75(2): 467 - 471.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. M. Jennings, A. El-Gatit, Z. L. Nagy, J. Fisher, P. G. Walker, and K. G. Watterson
Hydrodynamic function of the second-generation mitroflow pericardial bioprosthesis
Ann. Thorac. Surg., July 1, 2002; 74(1): 63 - 68.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Cohen, G. T. Christakis, C. D. Joyner, C. D. Morgan, M. Tamariz, N. Hanayama, H. Mallidi, J.P. Szalai, M. Katic, V. Rao, et al.
Are stentless valves hemodynamically superior to stented valves? A prospective randomized trial
Ann. Thorac. Surg., March 1, 2002; 73(3): 767 - 778.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. S. Goldman, T. E. David, J. R. Wood, J. R. Pepper, S. M. Goldman, E. D. Verrier, and M. R. Petracek
Clinical outcomes after aortic valve replacement with the Toronto stentless porcine valve
Ann. Thorac. Surg., May 1, 2001; 71 (2007): S302 - S305.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The American Association for Thoracic Surgery.