JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Eugene H. Blackstone
Delos M. Cosgrove
John H. Lemmer, Jr
D. Craig Miller
Eric G. Butchart
Giulio Rizzoli
Magdi Yacoub
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blackstone, E. H.
Right arrow Articles by Chai, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blackstone, E. H.
Right arrow Articles by Chai, A.
Related Collections
Right arrow Valve disease

J Thorac Cardiovasc Surg 2003;126:783-793
© 2003 The American Association for Thoracic Surgery


Surgery for acquired cardiovascular disease

Prosthesis size and long-term survival after aortic valve replacement

Eugene H. Blackstone, MDa,b,*, Delos M. Cosgrove, MDa, W.R. Eric Jamieson, MDc, Nancy J. Birkmeyer, PhDd, John H. Lemmer, Jr, MDe, D. Craig Miller, MDf, Eric G. Butchart, FRCSg, Giulio Rizzoli, MDh, Magdi Yacoub, MDi, Akiko Chai, MSj

a Department of Thoracic and Cardiovascular Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio, USA,
b Department of Biostatistics and Epidemiology, The Cleveland Clinic Foundation, Cleveland, OhioUSA
c The University of British Columbia, Vancouver, British Columbia, Canada
d Dartmouth Medical School, Dartmouth-Hitchcock Medical Center, Lebanon, NHUSA
e Northwest Surgical Associates, Portland, OreUSA
f Stanford University, Stanford, CalifUSA
g University Hospital, Cardiff, United Kingdom
h Instituto Chirurgia Cardiovascolare, University of Padova, Padova, Italy
i Harefield Hospital, London, United Kingdom
j Edwards Lifesciences Corporation, Irvine, CalifUSA

Read at the Eightieth Annual Meeting of The American Association for Thoracic Surgery, Toronto, Ontario, Canada, April 30–May 3, 2000.

Received for publication April 28, 2000; revisions received November 27, 2002; accepted for publication February 26, 2003.

* Address for reprints: Eugene H. Blackstone, MD, The Cleveland Clinic Foundation, 9500 Euclid Ave, Desk F25, Cleveland, OH 44195, USA
blackse{at}ccf.org

OBJECTIVE: This study was undertaken to quantify the relationship between prosthesis size adjusted for patient size (prosthesis-patient size) and long-term survival after aortic valve replacement.

METHODS: Data from nine representative sources on 13,258 aortic valve replacements provided 69,780 patient-years of follow-up (mean 5.3 ± 4.7 years), with reliable survival estimates to 15 years. Prostheses included 5757 stented porcine xenografts, 3198 stented bovine pericardial xenografts, 3583 mechanical valves, and 720 allografts. Manufacturers’ labeled prosthesis size was 19 mm or smaller in 1109 patients. Expressions of prosthesis-patient size assessed were indexed internal prosthesis orifice area (in centimeters squared per square meter of body surface area) and standardized internal prosthesis orifice size (Z, the number of SDs from mean normal native aortic valve size). Multivariable hazard domain analysis with balancing score and risk factor adjustment quantified the association of prosthesis-patient size with survival.

RESULTS: Prosthesis-patient size down to at least 1.1 cm2/m2 or -3 Z did not adversely affect intermediate- or long-term survival (P > .2). However, 30-day mortality increased 1% to 2% when indexed orifice area fell below 1.2 cm2/m2 (P = .002) or standardized orifice size fell below -2.5 Z (P = .0003). The increased early risk affected fewer than 1% of patients receiving bioprostheses but about 25% of those receiving mechanical devices.

CONCLUSIONS: Aortic prosthesis-patient size down to 1.1 cm2/m2 or -3 Z did not reduce intermediate- or long-term survival after aortic valve replacement. However, patient-prosthesis size under 1.2 cm2/m2 or -2.5 Z was associated with a 1% to 2% increase in 30-day mortality. Prosthesis-patient sizes this small or smaller were rarely implanted in patients receiving bioprostheses.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The American Association for Thoracic Surgery.