JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Narutoshi Hibino
Takahiko Sakamoto
Masayoshi Nagatsu
Hiromi Kurosawa
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shin’oka, T.
Right arrow Articles by Kurosawa, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shin’oka, T.
Right arrow Articles by Kurosawa, H.
Related Collections
Right arrow Cardiac - other
Right arrow Congenital - acyanotic
Right arrow Congenital - cyanotic
Right arrow Great vessels

J Thorac Cardiovasc Surg 2005;129:1330-1338
© 2005 The American Association for Thoracic Surgery


Surgery for Congenital Heart Disease

Midterm clinical result of tissue-engineered vascular autografts seeded with autologous bone marrow cells

Toshiharu Shin’oka, MD, PhD*, Goki Matsumura, MD, PhD, Narutoshi Hibino, MD, Yuji Naito, MD, Manabu Watanabe, MD, Takeshi Konuma, MD, Takahiko Sakamoto, MD, PhD, Masayoshi Nagatsu, MD, PhD, Hiromi Kurosawa, MD, PhD

Department of Cardiovascular Surgery, The Heart Institute of Japan, Tokyo Women’s Medical University, Tokyo, Japan.

Read at the Eighty-fourth Annual Meeting of The American Association for Thoracic Surgery, Toronto, Ontario, Canada, April 25–28, 2004.

Received for publication April 23, 2004; revisions received December 21, 2004; accepted for publication December 23, 2004.

* Address for reprints: Toshiharu Shin’oka, MD, PhD, Department of Cardiovascular Surgery, The Heart Institute of Japan, Tokyo Women’s Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan. (Email: ssinoka{at}hij.twmu.ac.jp).

OBJECTIVE: Prosthetic and bioprosthetic materials currently in use lack growth potential and therefore must be repeatedly replaced in pediatric patients as they grow. Tissue engineering is a new discipline that offers the potential for creating replacement structures from autologous cells and biodegradable polymer scaffolds. In May 2000, we initiated clinical application of tissue-engineered vascular grafts seeded with cultured cells. However, cell culturing is time-consuming, and xenoserum must be used. To overcome these disadvantages, we began to use bone marrow cells, readily available on the day of surgery, as a cell source. The aim of the study was to assess the safety and feasibility of this technique for creating vascular tissue under low-pressure systems such as pulmonary artery or venous pressure.

METHODS: Since September 2001, tissue-engineered grafts seeded with autologous bone marrow cells have been implanted in 42 patients. The patients or their parents were fully informed and had given consent to the procedure. A 5-mL/kg specimen of bone marrow was aspirated with the patient under general anesthesia before the skin incision. The polymer tube serving as a scaffold for the cells was composed of a copolymer of L-lactide and {epsilon}-caprolactone (50:50). This copolymer is degraded by hydrolysis. The matrix is more than 80% porous, and the diameter of each pore is 20 to 100 µm. Polyglycolic acid woven fabric with a thickness of 0.5 mm was used for reinforcement. Twenty-three tissue-engineered conduits (grafts for extracardiac total cavopulmonary connection) and 19 tissue-engineered patches were used for the repair of congenital heart defects. The patients’ ages ranged from 1 to 24 years (median 5.5 years). All patients underwent a catheterization study, computed tomographic scan, or both, for evaluation after the operation. The patients received anticoagulation therapy for 3 to 6 months after surgery.

RESULTS: Mean follow-up after surgery was 490 ± 276 days (1.3–31.6 months, median 16.7 months). There were no complications such as thrombosis, stenosis, or obstruction of the tissue-engineered autografts. One late death at 3 months after total cavopulmonary connection was noted in patient with hypoplastic left heart syndrome; this was unrelated to the tissue-engineered graft function. There was no evidence of aneurysm formation or calcification on cineangiography or computed tomography. All tube grafts were patent, and the diameter of the tube graft increased with time (110% ± 7 % of the implanted size).

CONCLUSION: Biodegradable conduits or patches seeded with autologous bone marrow cells showed normal function (good patency to a maximum follow-up of 32 months). As living tissues, these vascular structures may have the potential for growth, repair, and remodeling. The tissue-engineering approach may provide an important alternative to the use of prosthetic materials in the field of pediatric cardiovascular surgery. Longer follow-up is necessary to confirm the durability of this approach.





This article has been cited by other articles:


Home page
FASEB J.Home page
B. Zavan, V. Vindigni, S. Lepidi, I. Iacopetti, G. Avruscio, G. Abatangelo, and R. Cortivo
Neoarteries grown in vivo using a tissue-engineered hyaluronan-based scaffold
FASEB J, August 1, 2008; 22(8): 2853 - 2861.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. Torikai, H. Ichikawa, K. Hirakawa, G. Matsumiya, T. Kuratani, S. Iwai, A. Saito, N. Kawaguchi, N. Matsuura, and Y. Sawa
A self-renewing, tissue-engineered vascular graft for arterial reconstruction
J. Thorac. Cardiovasc. Surg., July 1, 2008; 136(1): 37 - 45.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. A. Mettler, V. L. Sales, C. L. Stucken, V. Anttila, K. Mendelson, J. Bischoff, and J. E. Mayer Jr
Stem cell-derived, tissue-engineered pulmonary artery augmentation patches in vivo.
Ann. Thorac. Surg., July 1, 2008; 86(1): 132 - 141.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
S. Yokoya, Y. Mochizuki, Y. Nagata, M. Deie, and M. Ochi
Tendon-Bone Insertion Repair and Regeneration Using Polyglycolic Acid Sheet in the Rabbit Rotator Cuff Injury Model
Am. J. Sports Med., July 1, 2008; 36(7): 1298 - 1309.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
G. N. Nelson, T. Mirensky, M. P. Brennan, J. D. Roh, T. Yi, Y. Wang, and C. K. Breuer
Functional Small-Diameter Human Tissue-Engineered Arterial Grafts in an Immunodeficient Mouse Model: Preliminary Findings
Arch Surg, May 1, 2008; 143(5): 488 - 494.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. E. Mayer
Tissue Engineering for Cardiac Valve Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 1649 - 1656.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. Lee, C.-H. Lee, S. W. Hwang, H. G. Lim, S.-J. Kim, J. Y. Lee, W.-S. Shim, and W.-H. Kim
Midterm follow-up of the status of Gore-Tex graft after extracardiac conduit Fontan procedure
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1008 - 1012.
[Abstract] [Full Text] [PDF]


Home page
Mol. Interv.Home page
K.-E. Andersson and G. J. Christ
REGENERATIVE PHARMACOLOGY: THE FUTURE IS NOW
Mol. Interv., April 1, 2007; 7(2): 79 - 86.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Schmidt, L. M. Asmis, B. Odermatt, J. Kelm, C. Breymann, M. Gossi, M. Genoni, G. Zund, and S. P. Hoerstrup
Engineered living blood vessels: functional endothelia generated from human umbilical cord-derived progenitors.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1465 - 1471.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
W.-H. Zimmermann, M. Didie, S. Doker, I. Melnychenko, H. Naito, C. Rogge, M. Tiburcy, and T. Eschenhagen
Heart muscle engineering: An update on cardiac muscle replacement therapy
Cardiovasc Res, August 1, 2006; 71(3): 419 - 429.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. P. Hoerstrup, I. Cummings MRCS, M. Lachat, F. J. Schoen, R. Jenni, S. Leschka, S. Neuenschwander, D. Schmidt, A. Mol, C. Gunter, et al.
Functional Growth in Tissue-Engineered Living, Vascular Grafts: Follow-Up at 100 Weeks in a Large Animal Model
Circulation, July 4, 2006; 114(1_suppl): I-159 - I-166.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
A. Patel, B. Fine, M. Sandig, and K. Mequanint
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
Cardiovasc Res, July 1, 2006; 71(1): 40 - 49.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 by The American Association for Thoracic Surgery.