JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow VIDEO
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Nikolay V. Vasilyev
Alistair Phillips
Pedro J. del Nido
Emile A. Bacha
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vasilyev, N. V.
Right arrow Articles by Bacha, E. A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Vasilyev, N. V.
Right arrow Articles by Bacha, E. A.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Minimally invasive surgery
Right arrowRelated Article

J Thorac Cardiovasc Surg 2008;135:603-609
© 2008 The American Association for Thoracic Surgery


Evolving Technology

Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: A preclinical study

Nikolay V. Vasilyev, MDa, Ivan Melnychenko, MDa, Kazuo Kitahori, MD, PhDa, Franz P. Freudenthal, MDb, Alistair Phillips, MDc, Rainer Kozlik-Feldmann, MDd, Ivan S. Salgo, MD, MSe, Pedro J. del Nido, MDa, Emile A. Bacha, MDa,*

a Departments of Cardiac Surgery and Anesthesia, Children's Hospital Boston, Harvard Medical School, Boston, Mass
b Department of Pediatric Cardiology, Kardiozentrum, La Paz, Bolivia
c Department of Pediatric Cardiothoracic Surgery, Columbus Children's Hospital, Columbus, Ohio
d Department of Pediatric Cardiology, Grosshadern University Hospital, University of Munich, Munich, Germany
e Ultrasound Division, Philips Medical Systems, Andover, Mass

* Address for reprints: Emile A. Bacha, MD, Department of Cardiac Surgery, Children's Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (Email: emile.bacha{at}cardio.chboston.org).

Objectives: Safe and effective device closure of ventricular septal defects remains a challenge. We have developed a transcardiac approach to close ventricular septal defects using a patch delivery and fixation system that can be secured under real-time three-dimensional echocardiographic guidance.

Methods: In Yorkshire pigs (n = 8) a coring device was introduced into the left ventricle through a purse-string suture placed on the left ventricular apex, and a muscular ventricular septal defect was created. The patch deployment device containing a 20-mm polyester patch was advanced toward the ventricular septal defect through another purse-string suture on the left ventricular apex, and the patch was deployed under real-time three-dimensional echocardiographic guidance. The anchor delivery device was then introduced into the left ventricle through the first purse-string suture. Nitinol anchors to attach the patch around the ventricular septal defect were deployed under real-time three-dimensional echocardiographic guidance. After patch attachment, residual shunts were sought by means of two-dimensional and three-dimensional color Doppler echocardiography. The heart was then excised, and the septum with the patch was inspected.

Results: A ventricular septal defect was created in the midventricular (n = 4), anterior (n = 2), and apical (n = 2) septum. The mean size was 9.8 mm (8.2–12.0 mm), as determined by means of two-dimensional color Doppler scanning. The ventricular septal defects were completely closed in 7 animals. In one a 2.4-mm residual shunt was identified. No anatomic structures were compromised.

Conclusions: Beating-heart perventricular muscular ventricular septal defect closure without cardiopulmonary bypass can be successfully achieved by using a catheter-based patch delivery and fixation system under real-time three-dimensional echocardiographic guidance. This approach might be a better alternative to cardiac surgery or transcatheter device closure.



Abbreviations and Acronyms ASD = atrial septal defect; LV = left ventricle; RT3DE = real-time three-dimensional echocardiography; 3D = three-dimensional; 3DUS = three-dimensional ultrasonography; VSD = ventricular septal defect



Related Article

Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: A preclinical study
Nikolay V. Vasilyev, Ivan Melnychenko, Kazuo Kitahori, Franz P. Freudenthal, Alistair Phillips, Rainer Kozlik-Feldmann, Ivan S. Salgo, Pedro J. del Nido, and Emile A. Bacha
J. Thorac. Cardiovasc. Surg. 2008 135: 603-609. [Abstract] [Full Text] [PDF]






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 by The American Association for Thoracic Surgery.