JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bernhard, W. F.
Right arrow Articles by Carr, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bernhard, W. F.
Right arrow Articles by Carr, J. G.

The Journal of Thoracic and Cardiovascular Surgery, Vol 70, 880-895, Copyright © 1975 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

A new method for temporary left ventricular bypass. Preclinical appraisal

WF Bernhard, V Poirier, CC LaFarge and JG Carr

Surgical patients who cannot be weaned from cardiopulmonary bypass during operation or who develop balloon-dependent left ventricular failure postoperatively are now considered unsavable. However, in those with potentially reversible ventricular dysfunction, recovery might be possible if an improved means of temporary circulatory support were available. Towards this end, a pneumatically actuated, left ventricular assist pump was developed and evaluated in 20 consecutive calf experiments. The device, containing a flexible polyurethane pumping chamber, was positioned on the chest wall and connected to the left ventricular apex and descending thoracic aorta by two Dacron valved conduits (xenograft valves). All animals survived a 14 to 30 day pumping interval, and 7 underwent successful removal of the device by division of the Dacron conduits below skin level. As a prelude to human investigation, pumps were implanted during a series of routine autopsies through midline sternotomy incison. The device was positioned on the right anterolateral chest wall, with two valved conduits traversing the mediastinum to connect the pump to the left ventricular apex and ascending aorta.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T. Scott-Burden, J. P. Bosley, D. Rosenstrauch, K. D. Henderson, F. J. Clubb Jr, H. C. Eichstaedt, K. Eya, I. Gregoric, T. J. Myers, B. Radovancevic, et al.
Use of autologous auricular chondrocytes for lining artificial surfaces: a feasibility study
Ann. Thorac. Surg., May 1, 2002; 73(5): 1528 - 1533.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
J. Hager, F. Brandstaetter, O. Dietze, I. Koller, and F. Unger
The Spindle Pump--A Nonpulsatile Blood Pump for Assisted Circulation
J Biomater Appl, January 1, 1990; 4(3): 225 - 330.



Home page
VASC ENDOVASCULAR SURGHome page
K. Taguchi
Pre- and Postoperative Left Ventricular Bypass Support in Patients With Myocardial Infarction
Vascular and Endovascular Surgery, July 1, 1980; 14(4): 282 - 289.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1975 by The American Association for Thoracic Surgery.