The Journal of Thoracic and Cardiovascular Surgery, Vol 76, 381-384, Copyright © 1978 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association
GN Morritt, MP Jamieson, JB Irving, RM Marquis and PR Walbaum
The features and course of a patient in whom a fistula developed between
the left ventricle and the coronary sinus following replacement of a faulty
mitral valve prosthesis are described. The subsequent deterioration of her
condition was associated with a pansystolic murmur and periprosthetic
regurgitation. Replacement by a third prosthesis was complicated in
addition by tricuspid regurgitation. The fistula was not suspected until
the fourth operation, when the right atrium was opened for tricuspid
annuloplasty. The fistula was repaired successfully, and the woman has made
good progress postoperatively.
ARTICLES
Development of left ventricular--coronary sinus fistula following replacement of mitral valve prosthesis
This article has been cited by other articles:
![]() |
L. F. Lopez Almodovar, J. J. Rufilanchas, F. Enriquez, L. Maroto, E. Perez de la Sota, and J. Cortina Left ventricular-coronary sinus/right ventricular fistula late after mitral valve replacement Ann. Thorac. Surg., April 1, 2004; 77(4): 1441 - 1443. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Tokunaga, M. Yoshitoshi, H. Mayumi, E. Nakano, Y. Toshima, Y. Kawachi, and H. Yasui Left Ventricular-Coronary Sinus Shunt Through a Septal Aneurysm After Mitral Valve Re-replacement Ann. Thorac. Surg., January 1, 1995; 59(1): 224 - 227. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |