JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lundell, D. C.
Right arrow Articles by Wolfson, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lundell, D. C.
Right arrow Articles by Wolfson, S.

The Journal of Thoracic and Cardiovascular Surgery, Vol 81, 297-301, Copyright © 1981 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Randomized comparison of the modified wire-guided and standard intra- aortic balloon catheters

DC Lundell, GL Hammond, AS Geha, H Laks and S Wolfson

We have designed a modified intra-aortic balloon (IAB) catheter to facilitate balloon insertion and minimize the complications of vascular dissection, perforation, and thrombosis. The modified balloon catheter is fabricated of a new polyurethane, Avcomat-100; it has a central lumen which allows for pressure monitoring, contrast injection, and introduction of a guide-wire under fluoroscopic control. In a randomized study, we compared the modified balloon with the standard Avco balloon catheter. Eighteen patients were randomized, 10 to receive a standard balloon catheter (control group) and eight to receive a modified balloon catheter. In two of the 10 patients assigned to the control group, introduction of the standard catheter failed but a central-lumen balloon was successfully introduced using the guide wire. A guide wire was needed for introduction of the modified balloon in three of the eight patients assigned to the central-lumen catheter group. The Avcomat-100 catheter material was less thrombogenic, with a lower rate of femoral thrombosis--20% in the control group and 0% in the central-lumen group. Scanning electron miroscopy also showed a reduced area of catheter surface covered with fibrin and clot. This study demonstrates the safety, decreased thrombogenicity, and increased facility of insertion of this new balloon catheter.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1981 by The American Association for Thoracic Surgery.