JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hammerschmidt, D. E.
Right arrow Articles by Jacob, H. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hammerschmidt, D. E.
Right arrow Articles by Jacob, H. S.

The Journal of Thoracic and Cardiovascular Surgery, Vol 81, 370-377, Copyright © 1981 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Complement activation and neutropenia occurring during cardiopulmonary bypass

DE Hammerschmidt, DF Stroncek, TK Bowers, CJ Lammi-Keefe, DM Kurth, A Ozalins, DM Nicoloff, RC Lillehei, PR Craddock and HS Jacob

Complement activation and pulmonary leukostasis with neutropenia occur in hemodialysis and filtration leukapheresis, with attendant pulmonary dysfunction. Wondering whether similar phenomena might attend cardiopulmonary bypass (CPB), we studied 34 patients undergoing coronary artery bypass operations. As in the other extracorporeal circulation systems, neutropenia (mean 44.7% +/- 4.3% SEM of prebypass PMN count) occurred during the first half hour of bypass and then a rebound neutrophilia followed. CH50 and C3H50 fell 22% to 25% (p for CH50 less than 0.01) during bypass, but C3 conversion and C5a were not demonstrable in patient plasmas. Nonetheless, polymorphonuclear neutrophils (PMNs) harvested late in bypass showed low adherence to nylon and selective chemotactic and aggregative insensitivity to C5a-- functional aberrations which are seen after exposure to activated complement. Furthermore, smaller infusions of activated complement into animals produced neutropenia than were required to achieve a detectable [C5a] in the plasma. We conclude that neutropenia during CPB probably results from complement activation below the threshold of detection; complement-stimulated PMNs deserve study as possible mediators of tissue injury occurring during CPB.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: Organ Damage
Card. Surg. Adult, January 1, 2008; 3(2008): 389 - 414.
[Full Text]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
Y. Orr, D. P. Wilson, J. M. Taylor, P. G. Bannon, C. Geczy, M. P. Davenport, and L. Kritharides
A kinetic model of bone marrow neutrophil production that characterizes late phenotypic maturation
Am J Physiol Regulatory Integrative Comp Physiol, April 1, 2007; 292(4): R1707 - R1716.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. L.C. Reddy, A. D. Grayson, A. Y. Oo, M. D. Pullan, T. Poonacha, and B. M. Fabri
Does off-pump surgery offer benefit in high respiratory risk patients? A respiratory risk stratified analysis in a propensity-matched cohort.
Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 126 - 131.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. W. Hammon Jr. and L. H. Edmunds Jr.
Extracorporeal Circulation: Organ Damage
Card. Surg. Adult, January 1, 2003; 2(2003): 361 - 388.
[Full Text]


Home page
PerfusionHome page
M. A. Ozatik, O. Tarcan, A. Kale, G. Askon, M. Balco, A. Undar, D. S. Kucukaksu, E. Sener, and O. Tasdemir
Do S100{beta} protein level increases due to inflammation during cardiopulmonary bypass occur without any neurological deficit?
Perfusion, September 1, 2002; 17(5): 335 - 338.
[Abstract] [PDF]


Home page
Eur Heart JHome page
A.L. Clark, M. Loebe, E.V. Potapov, K. Egerer, C. Knosalla, R. Hetzer, and S.D. Anker
Ventricular assist device in severe heart failure. Effects on cytokines, complement and body weight
Eur. Heart J., December 2, 2001; 22(24): 2275 - 2283.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. Schulze-Neick, J. Li, D. J. Penny, and A. N. Redington
Pulmonary vascular resistance after cardiopulmonary bypass in infants: Effect on postoperative recovery
J. Thorac. Cardiovasc. Surg., June 1, 2001; 121(6): 1033 - 1039.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. A. Chaney, R. A. Durazo-Arvizu, M. P. Nikolov, B. P. Blakeman, and M. Bakhos
Methylprednisolone does not benefit patients undergoing coronary artery bypass grafting and early tracheal extubation
J. Thorac. Cardiovasc. Surg., March 1, 2001; 121(3): 561 - 569.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
I. Alat, M. Yuksel, S. Buket, S. Nalbantgil, F. Askar, U. Bayindir, S. Tasbakan, A. Kokuludag, and A. Veral
The side-effects of cardiopulmonary bypass on the lungs: changes in bronchoalveolar lavage fluids
Perfusion, March 1, 2001; 16(2): 121 - 128.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Guler, K. Kirali, M. E. Toker, N. Bozbuga, S. N. Omeroglu, E. Akinci, and C. Yakut
Different CABG methods in patients with chronic obstructive pulmonary disease
Ann. Thorac. Surg., January 1, 2001; 71(1): 152 - 157.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Nagashima, Y. Imai, K. Seo, M. Terada, M. Aoki, T. Shin'oka, and M. Koide
Effect of hemofiltrated whole blood pump priming on hemodynamics and respiratory function after the arterial switch operation in neonates
Ann. Thorac. Surg., December 1, 2000; 70(6): 1901 - 1906.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Liu, Q. Wang, X. Zhu, D. Liu, S. Pan, Y. Ruan, and Y. Li
Pulmonary artery perfusion with protective solution reduces lung injury after cardiopulmonary bypass
Ann. Thorac. Surg., May 1, 2000; 69(5): 1402 - 1407.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Cartier, S. Brann, F. Dagenais, R. Martineau, and A. Couturier
SYSTEMATIC OFF-PUMP CORONARY ARTERY REVASCULARIZATION IN MULTIVESSEL DISEASE: EXPERIENCE OF THREE HUNDRED CASES
J. Thorac. Cardiovasc. Surg., February 1, 2000; 119(2): 221 - 229.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Yamazaki, H. Ooshima, A. Usui, T. Watanabe, and K. Yasuura
Protective effects of ONO-5046{middle dot}Na, a specific neutrophil elastase inhibitor, on postperfusion lung injury
Ann. Thorac. Surg., December 1, 1999; 68(6): 2141 - 2146.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. Birdi, M. Caputo, M. Underwood, A.J. Bryan, and G.D. Angelini
The effects of cardiopulmonary bypass temperature on inflammatory response following cardiopulmonary bypass
Eur. J. Cardiothorac. Surg., November 1, 1999; 16(5): 540 - 545.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Lonn, B. Peterzen, B. Carnstam, and H. Casimir-Ahn
Beating heart coronary surgery supported by an axial blood flow pump
Ann. Thorac. Surg., January 1, 1999; 67(1): 99 - 104.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Fingerle-Rowson, J. Auers, E. Kreuzer, M. Labeta, B. Schmidt, W. Samtleben, H. W. L. Ziegler-Heitbrock, and M. Blumenstein
Down-regulation of surface monocyte lipopolysaccharide-receptor cd14in patients on cardiopulmonary bypass undergoing aorta-coronary bypass operation
J. Thorac. Cardiovasc. Surg., May 1, 1998; 115(5): 1172 - 1178.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. M.G. van de Watering, J. Hermans, J. G.A. Houbiers, P. J. van den Broek, H. Bouter, F. Boer, M. S. Harvey, H. A. Huysmans, and A. Brand
Beneficial Effects of Leukocyte Depletion of Transfused Blood on Postoperative Complications in Patients Undergoing Cardiac Surgery : A Randomized Clinical Trial
Circulation, February 17, 1998; 97(6): 562 - 568.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M G Macey, D A McCarthy, U H Trivedi, G E Venn, D J Chambers, and K A Brown
Neutrophil adhesion molecule expression during cardiopulmonary bypass: a comparative study of roller and centrifugal pumps
Perfusion, September 1, 1997; 12(5): 293 - 301.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Mayumi, Q.-W. Zhang, A. Nakashima, M. Masuda, H. Kohno, Y. Kawachi, and H. Yasui
Synergistic Immunosuppression Caused by High-Dose Methylprednisolone and Cardiopulmonary Bypass
Ann. Thorac. Surg., January 1, 1997; 63(1): 129 - 137.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M.-C. Seghaye, J. Duchateau, R. G. Grabitz, J. Mertes, C. Marcus, K. Buro, B. J. Messmer, and G. von Bernuth
HISTAMINE LIBERATION RELATED TO CARDIOPULMONARY BYPASS IN CHILDREN: POSSIBLE RELATION TO TRANSIENT POSTOPERATIVE ARRHYTHMIAS
J. Thorac. Cardiovasc. Surg., May 1, 1996; 111(5): 971 - 981.
[Abstract] [Full Text]


Home page
PerfusionHome page
P. Hornick
Cardiopulmonary bypass and the adaptive immune system: perspectives on T cell function
Perfusion, May 1, 1996; 11(3): 281 - 290.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M.-C. Seghaye, MD, J. Duchateau, R. G. Grabitz, T. Wolffb, C. Marcus, W. Engelhardt, H. Hornchen, B. J. Messmer, and G. von Bernuth
EFFECT OF SODIUM NITROPRUSSIDE ON COMPLEMENT ACTIVATION INDUCED BY CARDIOPULMONARY BYPASS: A CLINICAL AND EXPERIMENTAL STUDY
J. Thorac. Cardiovasc. Surg., April 1, 1996; 111(4): 882 - 892.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, S. Cirri, D. Conti, A. Ditta, A. Boncilli, A. Frigiola, and L. Menicanti
Beneficial Effects of Duraflo II Heparin-Coated Circuits on Postperfusion Lung Dysfunction
Ann. Thorac. Surg., January 1, 1996; 61(1): 76 - 81.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M.-A. L. Ringdal, and V. Videm
High and Low Heparin Dose With Heparin-Coated Cardiopulmonary Bypass: Activation of Complement and Granulocytes
Ann. Thorac. Surg., December 1, 1995; 60(6): 1755 - 1761.
[Abstract] [Full Text]


Home page
CirculationHome page
K. H.T. Teoh, C. A. Bradley, J. Gauldie, and H. Burrows
Steroid Inhibition of Cytokine-Mediated Vasodilation After Warm Heart Surgery
Circulation, November 1, 1995; 92(9): 347 - 353.
[Abstract] [Full Text]


Home page
CirculationHome page
U. Mehlhorn, S. J. Allen, D. L. Adams, K. L. Davis, G. R. Gogola, E. R. de Vivie, and G. A. Laine
Normothermic Continuous Antegrade Blood Cardioplegia Does Not Prevent Myocardial Edema and Cardiac Dysfunction
Circulation, October 1, 1995; 92(7): 1940 - 1946.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. Kawahito, M. Kawakami, T. Fujiwara, H. Adachi, and T. Ino
Interleukin-8 and monocyte chemotactic activating factor responses to cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 99 - 102.
[Abstract] [Full Text]


Home page
PerfusionHome page
J. Perttila, M. Salo, and O. Peltola
Comparison of the effects of centrifugal versus roller pump on the immune response in open-heart surgery
Perfusion, July 1, 1995; 10(4): 249 - 256.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
E. Sivertssen, M. Abdelnoor, and N. B. Fjeld
Prolonged Aortic Cross-Clamping Time and Cardiopulmonary Bypass Time Have a Gradient Effect on Early Mortality in Open-Heart Surgery
Vascular and Endovascular Surgery, March 1, 1995; 29(2): 91 - 97.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. J. Zehr, R. S. Poston, P. C. Lee, K. Uthoff, P. Kumar, P. W. Cho, A. M. Gillinov, J. M. Redmond, J. A. Winkelstein, A. Herskowitz, et al.
Platelet Activating Factor Inhibition Reduces Lung Injury After Cardiopulmonary Bypass
Ann. Thorac. Surg., February 1, 1995; 59(2): 328 - 335.
[Abstract] [Full Text]


Home page
PerfusionHome page
J. Driessen, H. Dhaese, G. Fransen, P. Verrolst, L. Rondelez, L. Gevaert, M. van Becelaere, and E. Scheistraete
Pulsatile compared with nonpulsatile perfusion using a centrifugal pump for cardiopulmonary bypass during coronary artery bypass grafting. Effects on systemic haemodynamics, oxygenation, and inflammatory response parameters
Perfusion, January 1, 1995; 10(1): 3 - 12.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. Gadaleta, A. L. Fahey, M. Verma, W. Ko, K. H. Kreiger, O. W. Isom, and J. M. Davis
Neutrophil leukotriene generation increases after cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., October 1, 1994; 108(4): 642 - 647.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M.-C. Seghaye, J. Duchateau, R. G. Grabitz, G. Nitsch, C. Marcus, B. J. Messmer, and G. von Bernuth
Complement, leukocytes, and leukocyte elastase in full-term neonates undergoing cardiac operation
J. Thorac. Cardiovasc. Surg., July 1, 1994; 108(1): 29 - 36.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. Johnson, D. Thomson, T. Hurst, K. Prasad, T. Wilson, F. Murphy, A. Saxena, and I. Mayers
Neutrophil-mediated acute lung injury after extracorporeal perfusion
J. Thorac. Cardiovasc. Surg., May 1, 1994; 107(5): 1193 - 1202.
[Abstract] [Full Text]


Home page
PerfusionHome page
O. Moen, E. Fosse, J. Braten, C. Andersson, M. K. Fagerhol, P. Venge, K. Hegasen, and T. E. Mollnes
Roller and centrifugal pumps compared in vitro with regard to haemolysis, granulocyte and complement activation
Perfusion, March 1, 1994; 9(2): 109 - 117.
[Abstract] [PDF]


Home page
PerfusionHome page
F. De Somer, D. De Smet, M. Vanackere, G. Van Nooten, F. Caes, and J. Delanghe
Clinical evaluation of a new hollow fibre membrane oxygenator
Perfusion, January 1, 1994; 9(1): 57 - 64.
[Abstract] [PDF]


Home page
PerfusionHome page
D. A Palanzo, N. J Manley, R. M Montesano, G. L Yeisley, and D. Gordon
Clinical evaluation of the LeukoGuard (LG-6) arterial line filter for routine open-heart surgery
Perfusion, November 1, 1993; 8(6): 489 - 496.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Massaut, N. Hennebert, F. Deuvaert, and J. Vanderrieviere
Changes in plasma leucocyte elastase levels during coronary surgery and effects of steroids and nifedipine infusion
Perfusion, October 1, 1991; 6(4): 253 - 259.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Driessen, G. Fransen, L. Rondelez, E. Schelstraete, and L. Gevaert
Comparison of the standard roller pump and a pulsatile centrifugal pump for extracorporeal circulation during routine coronary artery bypass grafting
Perfusion, October 1, 1991; 6(4): 303 - 311.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Pradhan, J. Fleming, U. Nkere, J. Arnold, C. Wildevuur, and K. Taylor
Clinical experience with heparin-coated cardiopulmonary bypass circuits
Perfusion, July 1, 1991; 6(3): 235 - 242.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Leijala, K. Peltola, M. Aronen, S. Meri, and I. Louhimo
Comparison of hollow fibre membrane oxygenators during cardiopulmonary bypass in children: Dideco Masterflo versus Terumo Capiox II
Perfusion, January 1, 1990; 5(1): 33 - 43.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Sellman, T. Ivert, M. Blomback, and B. Semb
Haematological effects of a depth absorption arterial line filter during extracorporeal circulation
Perfusion, October 1, 1989; 4(4): 255 - 264.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
Y. Miyamoto, H. Matsuda, and Y. Kawashima
Deleterious Effects of Complement Activation on the Lungs during Extracorporeal Circulation and Its Inhibition by FUT-175
J Biomater Appl, July 1, 1989; 4(1): 56 - 68.
[Abstract]


Home page
PerfusionHome page
D.T. Pearson and B. McArdle
Haemocompatibility of membrane and bubble oxygenators
Perfusion, January 1, 1989; 4(1): 9 - 24.
[Abstract] [PDF]


Home page
PerfusionHome page
A T. Pezzella, A. Ascioti, and P. Ricardi
Noncardiogenic pulmonary oedema following cardiopulmonary bypass: report of two cases and review of the literature
Perfusion, January 1, 1988; 3(1): 21 - 28.
[Abstract] [PDF]


Home page
PerfusionHome page
W. van Oeveren and C. Wildevuur
Review article : Blood compatibility of cardiopulmonary bypass circuits
Perfusion, October 1, 1987; 2(4): 237 - 244.
[PDF]


Home page
PerfusionHome page
B. Glenville
Review article : Cardiac surgery using the patient's lungs as the oxygenator
Perfusion, July 1, 1987; 2(3): 161 - 166.
[PDF]


Home page
PerfusionHome page
A. Gaspardone, M. Ciavolella, D. Mercogliano, B. Marino, L. Chiariello, and G. Carlizzi
Complement activation by different cardiopulmonary bypass priming solutions
Perfusion, October 1, 1986; 1(4): 255 - 260.
[Abstract] [PDF]


Home page
PerfusionHome page
L. L Mickleborough, G. Arnold, and R. C-J Chiu
Complement consumption during cardiopulmonary bypass: bubble versus membrane oxygenators
Perfusion, October 1, 1986; 1(4): 261 - 269.
[Abstract] [PDF]


Home page
PerfusionHome page
D. T Pearson, B. McArdle, S. J Poslad, and A. Murray
A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: haemocompatibility studies
Perfusion, January 1, 1986; 1(2): 81 - 98.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1981 by The American Association for Thoracic Surgery.