JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ishihara, T.
Right arrow Articles by Roberts, W. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ishihara, T.
Right arrow Articles by Roberts, W. C.

The Journal of Thoracic and Cardiovascular Surgery, Vol 81, 747-757, Copyright © 1981 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Structure of bovine parietal pericardium and of unimplanted Ionescu- Shiley pericardial valvular bioprostheses

T Ishihara, VJ Ferrans, M Jones, SW Boyce and WC Roberts

To obtain a basis for the evaluation of postimplantation changes in bioprostheses made of parietal pericardium, we conducted comparative histologic, scanning and transmission electron microscopic studies of the structure of (1) normal bovine parietal pericardium, (2) glutaraldehyde-treated pericardial patches to be used for repair of cardiac defects, and (3) pericardial tissue cusps of unimplanted Ionescu-Shiley valves. Bovine parietal pericardium has three layers: (1) the serosa, or mesothelial cell layer; (2) the fibrosa, formed by diversely oriented, wavy bundles of collagen and by elastic fibers, and (3) the epipericardial connective tissue layer, which is partly continuous with the pericardiosternal ligaments. Pericardial patches and pericardial bioprosthetic cusps differ from normal pericardium by being denuded of mesothelium but they have normal degrees of waviness in their collagen. In Ionescu-Shiley valves, the inflow and outflow surfaces of each cusp correspond to the epipericardial and serosal surfaces of parietal pericardium, respectively. The inflow surfaces have a coarse texture, characterized by large bundles of collagen, and the outflow surfaces have numerous grooves, 10 to 30 mu in width and 20 mu in depth, which probably result from pressure exerted on the cuspidal surfaces by cotton material either during manufacturing or packing of the valves. Comparisons of the structure of bioprosthetic pericardial cusps and porcine aortic valve cusps show that the latter have reduced degrees of collagen waviness and a different layered structure: A layer similar to the spongiosa of aortic valve cusps is not present in pericardium. The functional implications of these observations are discussed in detail.


This article has been cited by other articles:


Home page
J Biomater ApplHome page
J. M. G. Paez and E. Jorge-Herrero
Assessment of Pericardium in Cardiac Bioprostheses: A Review
J Biomater Appl, April 1, 1999; 13(4): 351 - 388.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
K. P. Rao and C. Shanthi
Reduction of Calcification by Various Treatments in Cardiac Valves
J Biomater Appl, January 1, 1999; 13(3): 238 - 268.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1981 by The American Association for Thoracic Surgery.