JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schoen, F. J.
Right arrow Articles by Braunwald, N. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schoen, F. J.
Right arrow Articles by Braunwald, N. S.

The Journal of Thoracic and Cardiovascular Surgery, Vol 88, 208-216, Copyright © 1984 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Implications of late morphology of Braunwald-Cutter mitral heart valve prostheses

FJ Schoen, SH Goodenough, MI Ionescu and NS Braunwald

Interrelationships among silicone poppet wear, cloth wear, and tissue ingrowth were investigated in 14 retrieved Braunwald-Cutter heart valve prostheses following implantation of 37 to 118 (mean 83) months. Six aortic valves (mean 81 months) had severe cloth and poppet wear. In three the poppet had escaped. The lesser wear of the strut covering on the eight mitral valves (mean 84, range 37 to 108 months) was generally functionally insignificant. Mean decrease in mitral poppet diameter was 0.4% (range 0% to 1.5%), in contrast to a mean of 5.8% for aortic poppets. Histologic examination of the cloth/tissue complex demonstrated well-collagenized tissue ingrowth in areas of intact fabric with focal endothelial lining. Functionally trivial calcific deposits were often noted deep in the tissue coating, adjacent to cloth fibers or the strut metal. These results suggest that the mitral Braunwald-Cutter prosthesis need not be electively replaced without specific indication. A model is presented which explains the favorable clinical course demonstrated for mitral recipients and provides a rationale for the disparate clinicopathological behavior of mitral and aortic Braunwald-Cutter prostheses. Although inconsequential in this setting, the focal microcalcification noted in all mitral prostheses implanted for more than 72 months may have implications for the development of clinical cardiac assist devices for long-term application.