JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bosch, X.
Right arrow Articles by Pelletier, L. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bosch, X.
Right arrow Articles by Pelletier, L. C.

The Journal of Thoracic and Cardiovascular Surgery, Vol 88, 567-572, Copyright © 1984 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Early and late prognosis after reoperation for prosthetic valve replacement

X Bosch, JL Pomar and LC Pelletier

From 1969 to 1983, 89 patients underwent replacement of a prosthetic heart valve, an average of 66 months after initial implantation, because of primary failure of the prosthesis in 39 patients (44%), endocarditis in 16 (18%), systemic valve-related complications in 16 (18%), and periprosthetic leaks in 13 (15%). In the remaining five patients (5%), a prosthesis was removed concomitantly with the replacement of another native heart valve. A mechanical valve was replaced in 64 cases (72%) and a bioprosthesis in 25 (28%). Forty-six of the prostheses (52%) were in the mitral position, 37 (42%) were in the aortic position, and six patients (6%) underwent replacement of two prostheses. Preoperatively, four patients were in Functional Class I, 21 in Class II, 37 in Class III, and 27 in Class IV. There were 19 early deaths (21.3%). Early mortality was significantly higher with aortic (35.1%) than with mitral prosthetic valve replacement (8.7%, p less than 0.01). Preoperative diagnosis had a significant correlation with mortality, which was higher with infective endocarditis (62.5%) than with all other indications for operation (12.3%, p less than 0.001). No correlation was found with the preoperative clinical class of the patients. During the time period of this study, there was a marked decline in the mortality rate, which decreased from 29.2% prior to 1979 to 7.4% during the last 2 years (p less than 0.05). Actuarial survival was 60% at 5 years and 38% at 10 years after reoperation. Among the 53 survivors followed up for an average of 39 months, 47 (88.9%) remained in Class I or II and six were in Class III (11.3%) at last follow-up. A second prosthetic valve replacement (third valve replacement) was required in eight patients, three of whom died at re- replacement. Recent improvements in myocardial protection techniques, in the treatment of prosthetic valve endocarditis, and increased surgical experience have contributed to decrease the risk of reoperation for prosthetic valve replacement. Late results are similar to those of a first valve implantation.


This article has been cited by other articles:


Home page
CirculationHome page
K. Hasnat, E. J. Birks, J. Liddicoat, J. K. F. Hon, S. Edwards, S. Glennon, and M. H. Yacoub
Patient Outcome and Valve Performance Following a Second Aortic Valve Homograft Replacement
Circulation, November 9, 1999; 100(90002): II-42 - 47.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. S. Carr-White, S. Glennan, S. Edwards, F. D. Ferdinand, A. C. Desouza, J. R. Pepper, and M. H. Yacoub
Pulmonary Autograft Versus Aortic Homograft for Rereplacement of the Aortic Valve : Results From a Subset of a Prospective Randomized Trial
Circulation, November 9, 1999; 100(90002): II-103 - 106.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M.-B. Edwards, C. P. Ratnatunga, C. J. Dore, and K. M. Taylor
Thirty-day mortality and long-term survival following surgery for prosthetic endocarditis: a study from the UK heart valve registry
Eur. J. Cardiothorac. Surg., August 1, 1999; 14(2): 156 - 164.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Weerasinghe, M.-B. Edwards, and K. M. Taylor
First Redo Heart Valve Replacement : A 10-Year Analysis
Circulation, February 9, 1999; 99(5): 655 - 658.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Morishita, T. Mawatari, T. Baba, J. Fukada, and T. Abe
Re-Replacement for Prosthetic Valve Dysfunction: Analysis of Long-Term Results and Risk Factors
Ann. Thorac. Surg., March 1, 1998; 65(3): 696 - 699.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Kallewaard, A. Algra, J. Defauw, Y. d. Graaf, and B.-S. S. Group
Prophylactic Replacement Of BjOrk-Shiley Convexo-Concave Valves At Risk Of Strut Fracture
J. Thorac. Cardiovasc. Surg., March 1, 1998; 115(3): 577 - 581.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1984 by The American Association for Thoracic Surgery.