JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cosgrove, D. M.
Right arrow Articles by Williams, G. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cosgrove, D. M.
Right arrow Articles by Williams, G. W.

The Journal of Thoracic and Cardiovascular Surgery, Vol 89, 358-368, Copyright © 1985 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

In vivo hemodynamic comparison of porcine and pericardial valves

DM Cosgrove, BW Lytle, CC Gill, LA Golding, RW Stewart, FD Loop and GW Williams

The bovine pericardial valve and the SupraAnnular valve have been developed to improve the hemodynamic function of tissue valves. Hemodynamic performances of the standard Carpentier-Edwards porcine valve, the Carpentier-Edwards SupraAnnular valve, and the Carpentier- Edwards bovine pericardial valve were compared in the aortic position. One hundred patients undergoing aortic valve replacement were studied intraoperatively. Mean gradient across the valve decreased for standard and pericardial valves as valve size increased. At the same flow rate, the 23 mm pericardial valve had larger valve orifice areas, higher performance indices, and lower gradients than the 23 mm SupraAnnular valve. The SupraAnnular valve is hemodynamically superior to the standard Carpentier-Edwards porcine bioprosthesis. The Carpentier- Edwards pericardial valve, however, is less obstructive in the aortic position than either of the porcine valves.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. Narayan, B. C. Reeves, S. I.A. Rizvi, K. Shokrollahi, H. Ismail, G. D. Angelini, A. Nightingale, and M. Caputo
Hemodynamic Evaluation and Midterm Outcome of Aortic Valve Replacement With Size 19 Perimount Prosthetic Valve.
Ann. Thorac. Surg., December 1, 2008; 86(6): 1799 - 1803.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
2006 WRITING COMMITTEE MEMBERS, R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, et al.
2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons
Circulation, October 7, 2008; 118(15): e523 - e661.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al.
2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons
J. Am. Coll. Cardiol., September 23, 2008; 52(13): e1 - e142.
[Full Text] [PDF]


Home page
Card Surg AdultHome page
P. Stelzer
Stentless Aortic Valve Replacement: Porcine and Pericardial
Card. Surg. Adult, January 1, 2008; 3(2008): 915 - 934.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Nowell, E. Wilton, H. Markus, and M. Jahangiri
Antithrombotic therapy following bioprosthetic aortic valve replacement
Eur. J. Cardiothorac. Surg., April 1, 2007; 31(4): 578 - 585.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al.
ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons
J. Am. Coll. Cardiol., August 1, 2006; 48(3): e1 - e148.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. P.A. Puvimanasinghe, J. J.M. Takkenberg, M. J.C. Eijkemans, L. A. van Herwerden, W.R. E. Jamieson, G. L. Grunkemeier, J. D. F. Habbema, and A. J.J.C. Bogers
Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacement
Eur. J. Cardiothorac. Surg., March 1, 2006; 29(3): 374 - 379.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. P.A. Puvimanasinghe, J. J.M. Takkenberg, M. J.C. Eijkemans, E. W. Steyerberg, L. A. van Herwerden, G. L. Grunkemeier, J. D. F. Habbema, and A. J.J.C. Bogers
Prognosis After Aortic Valve Replacement With the Carpentier-Edwards Pericardial Valve: Use of Microsimulation
Ann. Thorac. Surg., September 1, 2005; 80(3): 825 - 831.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. Gao, Y. Wu, G. L. Grunkemeier, A. P. Furnary, and A. Starr
Durability of pericardial versus porcine aortic valves
J. Am. Coll. Cardiol., July 21, 2004; 44(2): 384 - 388.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Cohen
Reply
Ann. Thorac. Surg., August 1, 2003; 76(2): 657 - 658.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Le Tourneau, A. Vincentelli, G. Fayad, C. Savoye, O. H. Fabre, A. Prat, and H. Warembourg
Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match study
Ann. Thorac. Surg., December 1, 2002; 74(6): 2010 - 2015.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W.R. E. Jamieson, M. T. Janusz, J. MacNab, and C. Henderson
Hemodynamic comparison of second- and third-generation stented bioprostheses in aortic valve replacement
Ann. Thorac. Surg., May 1, 2001; 71 (2007): S282 - S284.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
X. Y. Jin and S. Westaby
Pericardial and porcine stentless aortic valves: are they hemodynamically different?
Ann. Thorac. Surg., May 1, 2001; 71 (2007): S311 - S314.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Takakura, T. Sasaki, K. Hashimoto, T. Hachiya, K. Onoguchi, M. Oshiumi, and S. Takeuchi
Hemodynamic evaluation of 19-mm Carpentier-Edwards pericardial bioprosthesis in aortic position
Ann. Thorac. Surg., February 1, 2001; 71(2): 609 - 613.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. Stahle
Homograft--the optimal aortic valve substitute?
Eur. Heart J., October 2, 2000; 21(20): 1644 - 1647.
[PDF]


Home page
CirculationHome page
T. Le Tourneau, C. Savoye, E. P. McFadden, D. Grandmougin, H.-F. Carton, J.-L. Hennequin, A. Dubar, G. Fayad, and H. Warembourg
Mid-Term Comparative Follow-Up After Aortic Valve Replacement with Carpentier-Edwards and Pericarbon Pericardial Prostheses
Circulation, November 9, 1999; 100(90002): II-11 - 16.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
N. Cam, H. Gercekoglu, S. Celik, M. Gursurer, G. Tayyareci, H. Karabulut, A. Narin, T. Tezel, and B. Yigiter
Dobutamine Stress Test to Evaluate Different Sizes of Prosthetic Aortic Valves
Asian Cardiovasc Thorac Ann, September 1, 1998; 6(3): 166 - 173.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. B. Luciani, P. Bertolini, B. Vecchi, and A. Mazzucco
Midterm results after aortic valve replacement with freehand stentless xenografts: a comparison of three prostheses
J. Thorac. Cardiovasc. Surg., June 1, 1998; 115(6): 1287 - 1291.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. L. McDonald, R. C. Daly, H. V. Schaff, C. J. Mullany, F. A. Miller, J. J. Morris, and T. A. Orszulak
Hemodynamic Performance of Small Aortic Valve Bioprostheses: Is There a Difference?
Ann. Thorac. Surg., February 1, 1997; 63(2): 362 - 366.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. F. Carpentier
Aortic Valve Replacement With a Pericardial Bioprosthesis
Ann. Thorac. Surg., February 1, 1997; 63(2): 599 - 600.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
G. T. Christakis, C. D. Joyner, C. D. Morgan, S. E. Fremes, K. J. Buth, J. Y. Sever, V. Rao, K. P. Panagiotopoulos, P. M. Murphy, and B. S. Goldman
Left Ventricular Mass Regression Early After Aortic Valve Replacement
Ann. Thorac. Surg., October 1, 1996; 62(4): 1084 - 1089.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. R. Aupart, A. L. Sirinelli, F. F. Diemont, Y. A. Meurisse, X. B. Dreyfus, and M. A. Marchand
The Last Generation of Pericardial Valves in the Aortic Position: Ten-Year Follow-up in 589 Patients
Ann. Thorac. Surg., February 1, 1996; 61(2): 615 - 620.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. M. Cosgrove, B. W. Lytle, P. C. Taylor, M. T. Camacho, R. W. Stewart, P. M. McCarthy, D. P. Miller, M. R. Piedmonte, and F. D. Loop
The Carpentier-Edwards pericardial aortic valve: Ten-year results
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 651 - 662.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. A. Moggio, R. W. Pooley, M. R. Sarabu, J. Christiana, A. W. Ho, and G. E. Reed
Experience with the Mitroflow aortic bioprosthesis
J. Thorac. Cardiovasc. Surg., August 1, 1994; 108(2): 215 - 220.
[Abstract] [Full Text]


Home page
J Biomater ApplHome page
Tingfei Xi, Fuying Liu, and Baoshu Xi
Effect of Pretreatment with Epoxy Compounds on the Mechanical Properties of Bovine Pericardial Bioprosthetic Materials
J Biomater Appl, January 1, 1992; 7(1): 61 - 75.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J.G. Dumesnil and A.P. Yoganathan
Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients
Eur. J. Cardiothorac. Surg., January 1, 1992; 6(suppl_1): S34 - S38.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1985 by The American Association for Thoracic Surgery.