JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Verschuere, I.
Right arrow Articles by Derom, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Verschuere, I.
Right arrow Articles by Derom, F.

The Journal of Thoracic and Cardiovascular Surgery, Vol 90, 765-770, Copyright © 1985 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Polydioxanone suture material in growing vascular anastomoses. Experimental study

I Verschuere, K Francois, J De Roose, G Berzsenyi and F Derom

We studied the growth of vascular anastomoses after use of absorbable suture material in 21 piglets. In six piglets, end-to-end anastomosis of the infrarenal aorta was performed with 5-0 continuous polypropylene suture; stenosis developed in two of these animals. In 15 piglets, continuous polydioxanone sutures were used for the anastomoses, and no stenosis developed. On the contrary, 14 of these anastomoses showed some degree of dilation at the anastomotic site. Burst testing to 300 mm Hg caused no disruption. On histologic examination, only scar tissue at media and intima with good degree of differentiation was noted. Growth of a vascular anastomosis after use of absorbable polydioxanone suture material seems to be perfectly possible without stricture formation. Because the growing process takes years instead of months in human beings, with obviously less stress at the anastomotic site, it is likely that dilatation at the level of the suture line will not occur in clinical use.


This article has been cited by other articles:


Home page
VASC ENDOVASCULAR SURGHome page
M. Storck, K.-H. Orend, and T. Schmitz-Rixen
Absorbable Suture in Vascular Surgery
Vascular and Endovascular Surgery, July 1, 1993; 27(6): 413 - 424.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
P. Aarnio, A. Harjula, A. Lehtola, H. Sariola, E. Merikallio, H. Huusari, and S. Mattila
Polydioxanone and Polypropylene Suture Materials in Experimental Coronary Artery Surgery with Free Internal Mammary Artery
Vascular and Endovascular Surgery, January 1, 1990; 24(1): 11 - 15.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
P. Aarnio, A. Harjula, A. Lehtola, H. Sariola, E. Merikallio, H. Huusari, and S. Mattila
Polydioxanone and Polypropylene Suture Materials in Experimental Coronary Artery Surgery with Free Internal Mammary Artery
Vascular and Endovascular Surgery, September 1, 1989; 23(5): 376 - 380.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1985 by The American Association for Thoracic Surgery.