JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grunkemeier, G. L.
Right arrow Articles by Starr, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grunkemeier, G. L.
Right arrow Articles by Starr, A.

The Journal of Thoracic and Cardiovascular Surgery, Vol 91, 918-923, Copyright © 1986 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management

GL Grunkemeier and A Starr

The first generation of aortic ball-valve prostheses, used until 1965, was associated with poppet damage owing to fatty infiltration of the silicone rubber ball, a phenomenon termed ball variance. For the Model 1000 Starr-Edwards valves, almost all cases were discovered before 8 years. However, a review of our patients still at risk with the original valve and poppet, prompted by other recent reports of late ball variance, has shown that severe variance can exist up to 20 years after implantation. There is a relationship between the year of valve implantation and the timing and severity of ball variance for the overall series of patients surviving operation, but for the subgroup currently at risk the sample sizes are too small to detect any difference, if one still exists. Only three of 12 patients in the current subset were found to have severe variance. Simple ball change has been the operation of choice. Prophylactic reoperation is not indicated in the current subset, but patients require careful follow-up and should be considered for reoperation should symptoms develop.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. Aoyagi, S. Fukunaga, K. Arinaga, Y. Yokokura, H. Yokokura, and N. Egawa
Late Re-operation for Aortic and Mitral Starr-Edwards Ball Valve Prostheses
Asian Cardiovasc Thorac Ann, December 1, 2006; 14(6): 467 - 471.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. L. Godje, T. Fischlein, K. Adelhard, G. Nollert, W. Klinner, and B. Reichart
Thirty-Year Results of Starr-Edwards Prostheses in the Aortic and Mitral Position
Ann. Thorac. Surg., March 1, 1997; 63(3): 613 - 619.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1986 by The American Association for Thoracic Surgery.