JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yoganathan, A. P.
Right arrow Articles by Jones, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yoganathan, A. P.
Right arrow Articles by Jones, M.

The Journal of Thoracic and Cardiovascular Surgery, Vol 95, 929-939, Copyright © 1988 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Bjork-Shiley Monostrut, Omni-Carbon, and Duromedics

AP Yoganathan, HW Sung, YR Woo and M Jones
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta 30332-0100.

The in vitro velocity and turbulent shear stress fields created by three new mechanical valve designs (size 27 mm) were studied in the aortic position under pulsatile flow conditions. The following valves were studied: Bjork-Shiley Monostrut tilting disc, Omni-Carbon tilting disc, and Duromedics bileaflet. All three valve designs created low pressure gradients with effective orifice areas in the range of 3.10 to 3.90 cm2. Both tilting disc designs created major and minor orifice jets, which were asymmetric in size. The peak velocities of the major and minor orifice jets were, however, of the same magnitude (200 cm/sec). The Omni-Carbon valve created a more even flow distribution through the minor orifice compared with the Bjork-Shiley design. Regions of stagnation/flow separation were observed immediately adjacent (ie, distal) to the minor orifice strut and the pivot guards of the Bjork-Shiley and Omni-Carbon valve designs, respectively. The Duromedics valve created relatively centralized flow. However, a major portion of the flow occurred through the two lateral orifices. Regions of flow separation/stagnation were observed adjacent to the valve sewing ring in the area of the valve pivot (hinge) mechanism. All three valve designs did create elevated turbulent shear stresses, with peak values in the range of 1000 to 2000 dynes/cm2 and mean values in the range of 100 to 1000 dynes/cm2. Such elevated shear stresses could cause sublethal and/or lethal damage to cellular blood elements. In an overall analysis, these new-generation low-profile mechanical valves are hemodynamically comparable to the Medtronic Hall and St. Jude Medical mechanical valves and are superior to the older-generation mechanical valves. However, it is unlikely that these valve designs will eliminate the problems of thrombosis, thromboembolic complications, and hemolysis.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Bech-Hanssen, K. Caidahl, I. Wallentin, P. Ask, and B. Wranne
Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study
J. Thorac. Cardiovasc. Surg., August 1, 2001; 122(2): 287 - 295.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Abe, K. Kamata, K. Kuwaki, K. Komatsu, and S. Komatsu
Ten Years' Experience of Aortic Valve Replacement With the Omnicarbon Valve Prosthesis
Ann. Thorac. Surg., April 1, 1996; 61(4): 1182 - 1187.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Nygaard, P. K. Paulsen, J. M. Hasenkam, E. M. Pedersen, and P. E. Rovsing
Turbulent stresses downstream of three mechanical aortic valve prostheses in human beings
J. Thorac. Cardiovasc. Surg., February 1, 1994; 107(2): 438 - 446.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
O. Lund
Late Chronic Hemolysis after Valve Replacement for Aortic Stenosis. Relation to Residual Hypertrophy and Impaired Left Ventricular Function
Angiology, October 1, 1990; 41(10): 836 - 847.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1988 by The American Association for Thoracic Surgery.