JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Higashidate, M.
Right arrow Articles by Imai, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Higashidate, M.
Right arrow Articles by Imai, Y.

The Journal of Thoracic and Cardiovascular Surgery, Vol 96, 88-91, Copyright © 1988 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Real-time measurement of tricuspid valve annular area for annuloplasty. Experimental study

M Higashidate, K Tamiya, H Kurosawa, Y Takanashi and Y Imai
Department of Pediatric Cardiovascular Surgery, Heart Institute of Japan, Tokyo Women's Medical College.

We used real-time measurement of the tricuspid valve annular area in anesthetized dogs to study the optimal size of the annular area for annuloplasty. During control conditions, the maximum tricuspid annular area appeared at the onset of ventricular systole. The minimum tricuspid annular area appeared between the ventricular isovolumic relaxation phase and the early ventricular filling phase. The maximum annular area varied in seven dogs between 2.18 and 3.10 cm2, and the minimum annular area ranged between 1.68 and 2.45 cm2. In regular sinus rhythm (heart rates 97 to 120 beats/min), the maximal decreases in tricuspid annular area during one cardiac cycle ranged from 14.3% to 23.6% of the maximum size. When the tricuspid annular area after the annuloplasty was kept larger than the minimum area that was observed during the cardiac cycle in the control study, cardiac output and right atrial pressure remained unchanged, as a result of unobstructed ventricular filling. On the other hand, when the annular area was reduced to smaller than the minimum area seen in the control study, a decrease in cardiac output and an elevation of right atrial pressure ensued. These findings suggest that the tricuspid annular area can be safely decreased by annuloplasty to the minimum area seen in the control study without causing a reduction of cardiac output or an elevation of right atrial pressure.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Higashidate, K. Tamiya, T. Beppu, and Y. Imai
REGULATION OF THE AORTIC VALVE OPENINGIn vivo dynamic measurement of aortic valve orifice area
J. Thorac. Cardiovasc. Surg., August 1, 1995; 110(2): 496 - 503.
[Abstract] [Full Text]