JTCS Concomitant Website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knott, E.
Right arrow Articles by Rau, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knott, E.
Right arrow Articles by Rau, G.

The Journal of Thoracic and Cardiovascular Surgery, Vol 96, 952-961, Copyright © 1988 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

In vitro comparison of aortic heart valve prostheses. Part 1: Mechanical valves

E Knott, H Reul, M Knoch, U Steinseifer and G Rau
Helmholtz-Institute for Biomedical Engineering, Aachen University of Technology, Federal Republic of Germany.

The hydrodynamic performance of a series of mechanical heart valve prostheses is measured in the aortic position. All experiments are performed in an electrohydraulic, computer-controlled pulse duplicator simulating the left side of the human circulatory system. Testing conditions are set according to a Food and Drug Administration interlaboratory comparison protocol with cardiac outputs of 3.0, 4.5, 6.5, and 8.0 L/min at a constant heart rate of 70 beats/min. Mean systolic pressure differences, volume losses, and energy losses, as well as dimensionless pressure losses and energy loss coefficients, are calculated from the recorded pressure, volume, and flow tracings. The results of 10 mechanical heart valve prostheses (eight tilting disc valves and two bileaflet valves) are presented and their clinical relevance is discussed.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Fries, T. Graeter, D. Aicher, H. Reul, C. Schmitz, M. Bohm, and H.-J. Schafers
In vitro comparison of aortic valve movement after valve-preserving aortic replacement
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 32 - 37.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. De Paulis, C. Schmitz, R. Scaffa, P. Nardi, L. Chiariello, and H. Reul
In vitro evaluation of aortic valve prosthesis in a novel valved conduit with pseudosinuses of Valsalva
J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 1016 - 1021.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. Hartrumpf, J. M. Albes, T. Krempl, V. Rudolph, and T. Wahlers
The hemodynamic performance of standard bileaflet valves is impaired by a tilted implantation position
Eur. J. Cardiothorac. Surg., March 1, 2003; 23(3): 283 - 291.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Niinami, S. Aomi, H. Tomioka, K. Nakano, and H. Koyanagi
A comparison of the in vivo performance of the 19-mm St. Jude medical hemodynamic plus and 21-mm standard valve
Ann. Thorac. Surg., October 1, 2002; 74(4): 1120 - 1124.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Torregrosa, J. Gomez-Plana, F. J. Valera, J. Caffarena, J. M. Maronas, F. Garcia-Sanchez, J. Peris, R. Frias, and J. M. Caffarena
Long-term clinical experience with the omnicarbon prosthetic valve
Ann. Thorac. Surg., September 1, 1999; 68(3): 881 - 886.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. Lund, K. Emmertsen, T. T. Nielsen, F. T. Jensen, C. Flo, H. K. Pilegaard, B. S. Rasmussen, O. K. Hansen, and L. H. Kristensen
Impact of Size Mismatch and Left Ventricular Function on Performance of the St. Jude Disc Valve After Aortic Valve Replacement
Ann. Thorac. Surg., May 1, 1997; 63(5): 1227 - 1234.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. A. Mikhail and C. W. Akins
Omniscience Valve Evolution and Literature
Ann. Thorac. Surg., August 1, 1996; 62(2): 624 - 626.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
T. Abe, K. Kamata, K. Kuwaki, K. Komatsu, and S. Komatsu
Ten Years' Experience of Aortic Valve Replacement With the Omnicarbon Valve Prosthesis
Ann. Thorac. Surg., April 1, 1996; 61(4): 1182 - 1187.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
S. A. Blome-Eberwein, D. Mrowinski, J. Hofmeister, and R. Hetzer
Impact of Mechanical Heart Valve Prosthesis Sound on Patients' Quality of Life
Ann. Thorac. Surg., February 1, 1996; 61(2): 594 - 602.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. Laske, R. Jenni, M. Maloigne, G. Vassalli, O. Bertel, and M. I. Turina
Pressure Gradients Across Bileaflet Aortic Valves by Direct Measurement and Echocardiography
Ann. Thorac. Surg., January 1, 1996; 61(1): 48 - 57.
[Abstract] [Full Text]


Home page
CirculationHome page
W. Voelker, H. Reul, G. N. Ing, T. S. Ing, B. S. Ing, A. S. Ing, and K. R. Karsch
Comparison of Valvular Resistance, Stroke Work Loss, and Gorlin Valve Area for Quantification of Aortic Stenosis : An In Vitro Study in a Pulsatile Aortic Flow Model
Circulation, February 15, 1995; 91(4): 1196 - 1204.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
O. Lund
Late Chronic Hemolysis after Valve Replacement for Aortic Stenosis. Relation to Residual Hypertrophy and Impaired Left Ventricular Function
Angiology, October 1, 1990; 41(10): 836 - 847.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS