JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klepetko, W.
Right arrow Articles by Wolner, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Klepetko, W.
Right arrow Articles by Wolner, E.

The Journal of Thoracic and Cardiovascular Surgery, Vol 97, 90-94, Copyright © 1989 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Leaflet fracture in Edwards-Duromedics bileaflet valves

W Klepetko, A Moritz, J Mlczoch, H Schurawitzki, E Domanig and E Wolner
Second Surgical Department, University of Vienna, Austria.

Two cases of leaflet fracture in the Edwards-Duromedics valve at 36 and 38 months after implantation are reported. Both patients were immediately reoperated on and recovered well. In one valve an older housing fracture with partial tissue ingrowth was noted beside a recent transverse leaflet fracture. In the other valve the leaflet was fractured near the pivot mechanism. All larger embolized parts were detected in the iliac artery region by computed tomographic scan and were subsequently removed. Problems in diagnosis and the importance of immediate reoperation, even without exact diagnosis, are discussed. Technical evaluation of the valve revealed crack growth and arrest, giving evidence of fatigue fracture. Scanning electron microscopic examination revealed several areas of pitting and erosion. Although the exact cause of mechanical disruption remains speculative, pyrolytic carbon seems to have the characteristic of fatigue fracture as well as erosion damage. A connection between the two might exist.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
R. F. Padera Jr. and F. J. Schoen
Pathology of Cardiac Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 111 - 178.
[Full Text]


Home page
Eur J EchocardiogrHome page
T. F. Cianciulli, J. A. Lax, M. C. Saccheri, H. J. Redruello, S. M. Belforte, V. P. Picone, and H. A. Prezioso
Acute mitral valve dysfunction due to leaflet escape in a Tri-technologies bileaflet mechanical valve
Eur J Echocardiogr, January 1, 2007; 8(1): 63 - 66.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
J Butany and M J Collins
Analysis of prosthetic cardiac devices: a guide for the practising pathologist
J. Clin. Pathol., February 1, 2005; 58(2): 113 - 124.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. A. Ferraris and S. P. Ferraris
Assessing the medical literature: let the buyer beware
Ann. Thorac. Surg., July 1, 2003; 76(1): 4 - 11.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
F. J. Schoen and R. F. Padera Jr.
Cardiac Surgical Pathology
Card. Surg. Adult, January 1, 2003; 2(2003): 119 - 185.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Kornberg, S. M. Wildhirt, C. Schulze, and E. Kreuzer
Leaflet escape in Omnicarbon monoleaflet valve
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 867 - 869.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. K. Podesser, G. Khuenl-Brady, E. Eigenbauer, S. Roedler, A. Schmiedberger, E. Wolner, and A. Moritz
Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: A prospective ten-year clinical follow-up
J. Thorac. Cardiovasc. Surg., May 1, 1998; 115(5): 1121 - 1129.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Vitale, D. Serena, C. Fondacone, A. Agnino, P. Cicala, and L. de Luca
COMPLETE INTRAOPERATIVE DISLODGMENT OF A ST. JUDE MEDICAL MECHANICAL HEART VALVE HEMODYNAMIC PLUS* VALVE SEWING CUFF
J. Thorac. Cardiovasc. Surg., December 1, 1996; 112(6): 1669 - 1671.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
A. E. Fiane, K. Saatvedt, J. L. Svennevig, O. Geiran, K. Nordstrand, and T. Froysaker
The CarboMedics Valve: Midterm Follow-up With Analysis of Risk Factors
Ann. Thorac. Surg., October 1, 1995; 60(4): 1053 - 1058.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The American Association for Thoracic Surgery.