|
|
||||||||
J Thorac Cardiovasc Surg 1996;112:94-102
© 1996 Mosby, Inc.
CARDIAC AND PULMONARY REPLACEMENT |
Supported by National Institutes of Health grant 1 R01 HL41281.
Received for publication Oct. 10, 1995 Accepted for publication Nov. 21, 1995. Address for reprints: G. Alexander Patterson, MD, Suite 3108, Queeny Tower, One Barnes Hospital Plaza, St. Louis, MO 63110.
Abstract
The optimal state of inflation for lung allografts during preservation is not known. We previously showed that hyperinflation of canine lung allografts during storage improved posttransplant graft function as measured during 10 minutes of contralateral pulmonary artery occlusion. However, we have also shown that hyperinflation during storage increases pulmonary capillary permeability. It is possible that short-term total cardiac perfusion through the transplanted left lung (for assessment) may not adequately reproduce the clinical situation. The purpose of this study was to assess the effects of hyperinflation during storage in a canine left single-lung transplantation model in which all perfusion was continuously directed to the graft after implantation. Twenty canine left single-lung transplants were done. The lungs of donor animals were ventilated at a tidal volume of 750 ml and an inspired oxygen fraction of 100%. Donor lungs were flushed with modified Euro-Collins solution and the trachea occluded at end inspiration. For donors in groups I and III, the trachea was sealed at that postinflation volume. In groups II and IV, 200 cc of air was withdrawn from the endotracheal tube under positive pressure and the trachea sealed at the lower tidal volume. Lungs were then extracted and stored at 1° C for 12 hours. After the preservation period, left lung transplants were performed. After implantation in all groups, the right pulmonary artery was ligated. In groups I and II, the right bronchus was ligated and in groups III and IV the right bronchus was kept open. Subsequent allograft gas exchange and hemodynamics were assessed during a 6-hour period of reperfusion. After assessment, both lungs were excised, wet/dry lung weight ratio was calculated, and histologic examination was done. During the 6-hour assessment, lungs stored in a state of hyperinflation (groups I and III) showed rapid deterioration of gas exchange. At the final assessment, arterial oxygen tension and alveolar-arterial oxygen gradient of groups I and III were significantly worse than those of groups II and IV (group I versus group II: arterial oxygen tension 87.5 ± 15.0 versus 373.8 ± 65.5 mm Hg, alveolar-arterial oxygen gradient 564.4 ± 13.2 versus 298.6 ± 69.3 mm Hg, p< 0.05; group III versus group IV: arterial oxygen tension 245.4 ± 33.0 versus 543.6 ± 41.8 mm Hg, alveolar-arterial oxygen gradient 392.5 ± 35.6 versus 120.5 ± 34.7 mm Hg, p< 0.01). We conclude that donor lung hyperinflation during storage does not provide better posttransplant allograft function when perfusion is limited only to the allograft. (J THORAC CARDIOVASC SURG 1996;112:94-102)
Although clinical lung transplantation has recently become an accepted therapy for end-stage pulmonary diseases,
1 early graft dysfunction remains a common and highly unpredictable problem. Numerous studies have been conducted in an effort to establish the optimal strategy for pulmonary allograft preservation. The optimal state of inflation or ventilation during lung preservation remains uncertain.
Homatas, Bryant, and Eiseman
2 demonstrated that continuous positive-pressure ventilation improved warm ischemic tolerance of the lung. Veith and associates
3 reported that a single lung could maintain adequate pulmonary function after 3 hours of normothermic ischemia if it was inflated or after 2 hours of ischemia if it was ventilated, whereas a deflated lung failed to provide adequate pulmonary function within a 1-hour ischemic period. Furthermore, Fonkalsrud and colleagues
4,5 revealed that lung expansion by positive end-expiratory pressure or static inflation with 10 cm water pressure maintained excellent pulmonary function in lungs after 4 to 10 hours of normothermic ischemia. Despite these results, in 1988, Todd and associates
6 published a technique for harvesting atelectatic left lung allografts, which was successfully used in the early experience of the Toronto group. In contrast, Puskas and associates
7 reported that the combination of large tidal volume and positive end-expiratory pressure during pulmonary flushing and hyperinflation during storage provided excellent early posttransplantation pulmonary function in a canine allotransplantation model.
In a previous study with use of a long-term canine left single-lung allotransplantation model in which graft function was assessed by brief 10-minute periods of contralateral pulmonary artery (PA) cuff occlusion, we demonstrated that donor hyperinflation improves posttransplant lung allograft function unpublished data.*
Furthermore, we suggested that this improvement could be attributed to the maintenance of lower alveolar surface tension during storage in hyperinflated grafts. However, previous reports have demonstrated that high airway pressure produces pulmonary edema.
8-11 Furthermore, recent work from our laboratory indicates that hyperinflation during storage increases pulmonary capillary filtration coefficient.
12 Finally, experience in our clinical lung transplant program suggests that hyperinflation results in a higher prevalence of immediate allograft dysfunction because of pulmonary edema. Our previous conflicting results that suggested that hyperinflation was beneficial might be explained by the brief 10-minute period of contralateral PA occlusion for allograft assessment used in that experimental model. Such a short period of total perfusion to the allograft might not have been long enough to demonstrate physiologic effects of hyperinflation-induced pulmonary capillary permeability.
The purpose of the present study was to reevaluate the effects of hyperinflation on posttransplant graft function by using a model in which the transplanted lung receives the entire cardiac output.
Material and methods
Donor procedure.
Forty adult mongrel dogs (body weight 24.2 to 30.4 kg) that served as donors and recipients were paired by weight and randomly assigned to one of four study groups (n = 5). Donor lung excision and storage were done by previously described techniques (Aoe and colleagues, unpublished data). The donors were anesthetized with sodium thiopental 10 mg/kg intravenously, followed by atropine 0.04 mg/kg intramuscularly, and intubated with a 9.0F special endotracheal tube to monitor intratracheal air pressure throughout the harvest procedure by means of a model 1290A transducer (Hewlett-Packard, Andover, Mass.). The lungs were ventilated with a tidal volume of 750 ml (approximately 35 ml/kg), a respiratory rate of 12 breaths/min, an inspired oxygen fraction of 1.0, and no positive end-expiratory pressure (Bennett MA1, Puritan Bennett, Inc., Overland Park, Kan.). The femoral artery was cannulated to monitor systemic arterial pressure during the harvest procedure.
After a median sternotomy, the thymus was removed and the azygos vein was divided. Both venae cavae and the aorta, PA, and trachea were isolated. Heparin (400 U/kg) was administered systemically and a 6.5 mm curved metal-tipped perfusion cannula (Sarns, Inc., Ann Arbor, Mich.) was inserted into the main PA just distal to the valve, secured with a purse-string suture, and connected by means of tubing to a bag of cold (1° C) modified Euro-Collins solution (4 mmol/L MaSO4 and 32.7 gm/L glucose added to the original Euro-Collins solution), which was hung at a height of 40 cm above the chest. After four 1600 ml tidal volume breaths were administered to eliminate atelectasis, the previous ventilatory parameters were resumed for 1 minute to allow the lungs to reach their baseline volume. Cardiac inflow occlusion was then accomplished by ligation of both venae cavae.
The left atrial appendage was amputated and the lungs were flushed by gravity pressure (40 cm H2O) with 50 ml/kg of Euro-Collins solution. Simultaneous topical cooling was achieved by intrathoracic immersion of the lungs in cold saline solution (1° to 4° C). After completion of the flush, the endotracheal tube was clamped at end-inspiration and the intratracheal air pressure was recorded on a Gould 2800 series recorder (Gould Inc., Cleveland, Ohio). At this point, animals were divided into two groups. In groups I (n = 5) and III (n = 5), no air was withdrawn and the trachea was stapled. In groups II (n = 5) and IV (n = 5), 200 ml of air was withdrawn gently through the tracheal tube under positive intratracheal pressure (Table I
). Intratracheal pressure was measured again and the trachea was stapled. The heart-lung block was then excised, placed in a plastic bag containing 1° C Euro-Collins solution, and preserved at 1° C for 12 hours.
|
After the completion of anastomoses, the left transplanted lung was inflated with 30 cm of water pressure once and ventilation and reperfusion were started. A Millar Mikro-Tip catheter pressure transducer (model SPC-370, Millar Instruments Inc., Houston, Tex.) was introduced through the mediastinal pulmonary vein into the left atrium and anchored. Two chest tubes were placed, connected to a waterseal bottle, and placed at 15 cm H2O pressure. In groups I and II, the right upper and lower bronchi were both individually ligated. Complete occlusion of the right-sided airway was confirmed by examination with a fiberoptic bronchoscope. At the same time, the right PA in all the groups was ligated. Thus the transplanted left lung received the total cardiac output in all groups.
In groups I and II only the transplanted lung was ventilated (Bennett model MA1, tidal volume 550 ml, respiratory rate 20 breaths/min, fraction of inspired oxygen 1.0, and 5 cm H2O positive end-expiratory pressure). In groups III and IV, both lungs were ventilated (Bennett model MA1, tidal volume 750 ml, respiratory rate 20 breaths/min, fraction of inspired oxygen 1.0, and 5 cm H2O positive end-expiratory pressure (Table I
). We chose to include these two groups (that is, both lungs ventilated) so as to create a situation comparable with that in our previous studies in which postimplantation allograft function had been assessed with both the native and transplanted lungs ventilated. Peak inspiratory pressures were recorded. The chest wall was then closed and animals turned to the supine position.
Assessment of lung function.
During the 6-hour assessment period, the level of anesthesia was maintained with periodic administration of intravenous sodium thiopental. Aortic, PA, central venous, and left atrial pressures were continuously recorded. Arterial and central venous blood gas values were analyzed every 15 minutes from the start of the assessment. Cardiac output was determined in triplicate by the thermodilution method every hour. Blood pH was normalized as necessary by administration of bicarbonate. Ringer's lactate solution was judiciously infused to maintain central venous pressure within a normal range. Edema fluid from the left lung was suctioned with a fiberoptic bronchoscope 10 minutes before each assessment. Total edema fluid volume aspirated during the assessment was measured. After the assessment, the animals were killed and both lungs were excised for pathologic study and wet/dry lung weight ratio measurement.
Statistical analysis.
All data are represented as mean plus or minus standard error of the mean. One-way analysis of variance (ANOVA) with repeated measures was used to determine whether an overall difference existed in graft function between the groups during the assessment. Additional comparison was done to determine where significant differences arose during the assessment. The other data were analyzed with one-way ANOVA. Statistical significance was accepted at 95% confidence limit, p < 0.05.
All animals received humane care in compliance with the "Principles of Laboratory Animal Care" formulated by the National Society for Medical Research and the "Guide for the Care and Use of Laboratory Animals" prepared by the National Academy of Science and published by the National Institutes of Health (NIH Publication No. 86-23, revised 1985).
Results
There were no significant differences in mean weight of donor and recipient dogs, flushing times, flushing pressures, excision times, implantation times, or total ischemic times between the groups (Table I
). However, airway pressures at extraction were significantly higher in groups I and III (7.7 ± 0.5 and 7.6 ± 0.4 mm Hg) compared with those in groups II and IV (3.0 ± 0.4 and 4.0 ± 0.2 mm Hg) (p < 0.01) (Table II
). The mean time from reperfusion to initial assessment was 15.6 ± 1.2 minutes in group I, 14.7 ± 1.7 minutes in group II, 12.6 ± 1.9 minutes in group III, and 12.4 ± 1.2 minutes in group IV.
|
Maximum airway pressure before chest closure.
The maximum airway pressure in group I was significantly lower than that in group II (group I versus group II: 30.0 ± 0.7 versus 33.4 ± 1.2 cm H2O; p < 0.05). There was no significant difference between groups III and IV (group III versus group IV: 25.0 ± 1.0 versus 25.2 ± 1.2 cm H2O; not significant) (Fig. 1).
|
|
|
|
|
|
Total volume of airway edema fluid.
Airway edema fluid was obtained from all of the group I and II animals. Total volume of airway edema fluid in group I was significantly greater than that in group II (group I versus group II: 940 ± 179 versus 193 ± 126 ml, p < 0.01) (Fig. 7). Two of five animals in group II and all group IV animals had no measurable edema fluid during the 6-hour assessment. Therefore no statistical comparison was made between groups III and IV.
|
Discussion
Puskas and associates
7 recently reported that increased ventilation volume during donor lung flush and hyperinflation during storage provide excellent preservation even in the absence of the vasodilator prostaglandin E1. We have demonstrated that graft hyperinflation during storage prevents the accumulation of serum protein in the alveolar space, maintains surface activity, and improves early postoperative lung function.
8 It might therefore be assumed that hyperinflation during storage improves early lung allograft function.
On the other hand, several studies have shown that excessive hyperdistension of the lung by either static inflation, high tidal volume, or positive end-expiratory pressure increases lung solute permeability
10,12 and produces pulmonary microvascular injury
11 and pulmonary edema.
8,9 Furthermore, we noted that the application of donor lung hyperinflation in a recent series of clinical lung transplants resulted in an increased prevalence of early allograft dysfunction as a result of pulmonary edema.
The canine left single-lung transplantation model with temporary contralateral PA occlusion, used by Puskas and colleagues
7 and in our previous study (Aoe and colleagues, unpublished data), was originally described by Jones and associates
13 in 1988. In that model, the contralateral PA is occluded temporarily with an inflatable cuff implanted around the right PA, which thereby directs blood flow to the transplanted left lung. Hence both the transplanted left lung and the native right lung, which has a normal pulmonary vascular resistance, are perfused for most of the posttransplantation period. Yet in the clinical situation of single-lung transplantation for pulmonary hypertension, or during explantation and implantation of the second lung in bilateral lung transplantation, a single allograft will receive most if not all of the cardiac output. Indeed, even when single-lung transplantation is used in emphysema or pulmonary fibrosis, the majority of cardiac output is directed to the allograft. In this situation a hyperventilation-induced permeability lesion would become evident. However, in the canine model used by Puskas and colleagues
7 and by us (Aoe and colleagues, unpublished data), the temporary 10-minute PA occlusion may permit underestimation of the permeability lesion.
Another problem with previous reports that used temporary balloon occlusion of the contralateral PA is the measurement of pulmonary capillary wedge pressure by balloon-tipped catheter inflation. With all flow to the allograft, balloon inflation in the allograft PA might give erroneous measurements of wedge pressure as a result of hemodynamic instability during balloon inflation.
14 Although we have used this technique in previous studies,
15 in the present study, a Millar Mikro-Tip catheter pressure transducer was introduced into the left atrium through the mediastinal pulmonary vein. This made it possible to obtain continuous and reliable values of left atrial pressure directly.
This current study demonstrates that immediate postpreservation lung function is satisfactory irrespective of the state of inflation during storage. However, gas exchange in the hyperinflated lungs deteriorated within the early reperfusion period and was significantly worse than that in lungs stored at normal volume. In this study we have also demonstrated that with both native and transplanted lungs ventilated and only the transplanted lung perfused, immediate function of hyperinflated lungs was satisfactory but once again deteriorated as transplanted lungs became edematous during the latter portion of the 6-hour reperfusion period. Allografts stored in a state of normal inflation appeared to have lower pulmonary compliance with ventilation preferentially directed to the native right lung during the initial phase of assessment. This may explain the initially poor gas exchange in group IV animals. However, once the transplanted lung became well ventilated it maintained adequate pulmonary function throughout the 6-hour assessment period.
The decision to use a tidal volume of 750 ml to hyperinflate lungs at harvest was based on the report of Fonkalsrud and colleagues
4 that lungs inflated with static 10 cm of water pressure provided superior preservation compared with lungs inflated with 25 cm of water pressure. Our previous study showed that a tidal volume of 750 ml was adequate to obtain a static inflation pressure of approximately 10 cm of water pressure (approximately 6 mm Hg; Aoe and colleagues, unpublished data). Additionally, that study revealed no microscopic lung parenchymal damage from such a tidal volume during the harvest procedure.
Air withdrawal after flushing in groups II and IV (normoinflation groups) was done to make the lungs more normally inflated and to create a significant difference in intraairway pressure between the groups. It should be emphasized that air was withdrawn gently under positive pressure to avoid uneven withdrawal and local microatelectasis. Lungs of the normoinflation groups were visibly smaller than the lungs of the hyperinflation groups stored after inflation with a tidal volume of 750 ml. Yet lungs from the normoinflation groups maintained a normal state of inflation during preservation and had no apparent local atelectasis on gross and microscopic examination.
It has been reported that preserved lungs maintain aerobic metabolism during storage and produce carbon dioxide
16 that replaces intraalveolar oxygen and dissolves into the flushing solution.
17 Haniuda and associates
12 demonstrated that donor lungs have a volume decrease during storage. Although some decrease in lung volume is inevitable, we have observed that, even 24 hours after harvest, no microatelectasis was found in the preserved lungs that had 200 ml of air withdrawn at harvest (Aoe and colleagues, unpublished data).
In the current study during the 6-hour assessment period we chose to use high tidal volumes of 550 ml in groups I and II (single lung ventilation) and 750 ml in groups III and IV (bilateral lung ventilation). This degree of hyperventilation was used to avoid acidosis. Acidosis will increase PA pressure and adversely affect graft function. Correction of pH solely by bicarbonate administration can require a large volume of fluid infusion and increase central venous pressure resulting in pulmonary edema and allograft dysfunction.
The model used in this study provides a severe test of allograft function. The ischemic time used is longer than the 6- to 8-hour ischemia acceptable in clinical lung transplant programs. Prolonged contralateral PA occlusion is capable of detecting a permeability defect that is not evident with shorter periods of temporary PA occlusion. The findings of the current study indicate that hyperinflation during storage is detrimental to subsequent allograft function. On the basis of these results, we no longer use hyperinflation in clinical lung harvests but rather harvest and store donor lungs in a state of normal end tidal inspiration.
Acknowledgments
We acknowledge the expert technical assistance of Donna Marquart, Timothy Morris, Dennis Gordon, Steven Labarbera, and Duane Probst and the secretarial support of Dawn Schuessler and Mary Ann Kelly. Preservation solutions were provided by Gary Queensen, RPh. Statistical advice was obtained from Richard B. Schuessler, PhD.
Footnotes
*Aoe M, Trachiotis GD, Manchester JK, et al. Effects of hyperinflation during storage in lung transplantation. ![]()
References
This article has been cited by other articles:
![]() |
S. J. Kao, D. Wang, D. Y.-W. Yeh, K. Hsu, Y. H. Hsu, and H. I. Chen Static Inflation Attenuates Ischemia/Reperfusion Injury in an Isolated Rat Lung In Situ Chest, August 1, 2004; 126(2): 552 - 558. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sugita, P. Ferraro, A. Dagenais, M.-E. Clermont, P. Barbry, R. P. Michel, and Y. Berthiaume Alveolar Liquid Clearance and Sodium Channel Expression Are Decreased in Transplanted Canine Lungs Am. J. Respir. Crit. Care Med., May 15, 2003; 167(10): 1440 - 1450. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. de Perrot, M. Liu, T. K. Waddell, and S. Keshavjee Ischemia-Reperfusion-induced Lung Injury Am. J. Respir. Crit. Care Med., February 15, 2003; 167(4): 490 - 511. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. FUKUSE, T. HIRATA, T. NAKAMURA, M. KAWASHIMA, S. HITOMI, and H. WADA Influence of Deflated and Anaerobic Conditions During Cold Storage on Rat Lungs Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 621 - 627. [Abstract] [Full Text] |
||||
![]() |
M. Haniuda, S. Hasegawa, T. Shiraishi, C. M. Dresler, J. D. Cooper, and G. A. Patterson EFFECTS OF INFLATION VOLUME DURING LUNG PRESERVATION ON PULMONARY CAPILLARY PERMEABILITY J. Thorac. Cardiovasc. Surg., July 1, 1996; 112(1): 85 - 93. [Abstract] [Full Text] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |