JTCS St. Jude Medical
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mulay, A. V.
Right arrow Articles by Nair, R. U.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Mulay, A. V.
Right arrow Articles by Nair, R. U.

J Thorac Cardiovasc Surg 1997;114:1128-1129
© 1997 Mosby, Inc.


LETTERS TO THE EDITOR

Should intraaortic balloon counterpulsation be continued during cardiopulmonary bypass?

Anvay V. Mulay , MCh, Sunny Zacharias , FRCS (CTh), Steve D. Hansbro, Roger W. Catchpole, R. Unnikrishnan Nair , FRCS

Department of Cardiothoracic Surgery
Department of Clinical Perfusion
Yorkshire Heart Centre
Leeds General Infirmary and Killingbeck Hospital
Leeds LS14 6UQ, United Kingdom
12/8/84307

To the Editor:

We read with interest the article by Torchiana and associatesGo 1 in the April 1997 issue of this Journal regarding trends in practice and outcome of intraaortic balloon (IAB) pumping for cardiac support. Using the strategy of preoperative insertion of the IAB, several other groups have also shown improvement in survival and reduced morbidity from perioperative infarction.Go Go 2-4 In many centers an IAB is now electively inserted in the preoperative period for indications such as evolving myocardial infarction, refractory unstable angina, failed percutaneous transluminal angioplasty necessitating emergency myocardial revascularization, complication of myocardial infarction with cardiogenic shock, or redo operations.Go Go 3-5 Very little, however, is mentioned about the continuation of IAB counterpulsation during cardiopulmonary bypass (CPB). If an IAB has to be inserted before the cardiac operation is begun, we prefer to continue counterpulsation throughout the operation. Counterpulsation is continued even during the period of aortic crossclamping on the intrinsic rate of the IAB and with 20% less than full augmentation. Once the heart starts ejecting, IAB counterpulsation can be synchronized with left ventricular diastole, unlike counterpulsation with conventional pulsatile pumps, to augment diastolic pumping and decrease systolic impedance. We temporarily stop the IAB pump only when clamping or unclamping the aorta.

Many surgeons stop IAB counterpulsation as soon as CPB is resumed, and counterpulsation is restarted while weaning the patient from CPB. We sent a questionnaire to 46 centers performing adult cardiac surgery in the United Kingdom and Ireland. From the 36 replies (78.2%) that we received, all surgeons at 29 centers (80.5%) stop IAB counterpulsation on commencing CPB. At one center the IAB pump is set on minimum volume and frequency, mainly to reduce the risk of clotting. At the remaining six centers counterpulsation is continued during CPB by all surgeons except one. It seems that not many surgeons make use of the potential advantages of having the IAB already in situ during CPB.

IAB counterpulsation effectively minimizes ischemic myocardial damage during induction of general anesthesia and during the pre-CPB period while conduits are being harvested.Go Go 2, 6 On initiation of CPB, systemic perfusion is maintained with reduced preload, which reduces myocardial oxygen needs significantly. The use of IAB counterpulsation during this period of CPB reduces afterload and also improves myocardial oxygen delivery.Go 7 Another potential benefit of IAB counterpulsation during CPB is pulsatile perfusion. The use of IAB counterpulsation as a simple method of achieving pulsatile flow during CPB was elucidated by Pappas and associatesGo 7 in 1975. This may result in better organ functionGo Go 8, 9 by the mechanism, not simply because of pulsatile flow but as an effect of the passive distention of the peripheral vascular bed owing to the propagation of the IAB-augmented diastolic pressure through the arterial system.Go 10 Combining IAB counterpulsation and CPB fulfils the need for greater hemodynamic support by pulsatile flow during diastole and unloading of the left ventricle during systole.Go 11 The patients in whom the use of IAB pumping is indicated before the operation are in a low cardiac output state. The renal and gastrointestinal perfusion in many of these patients is also suboptimal. Over recent years the importance of gastrointestinal perfusion has been more widely recognized with regard to patients in shock.Go 12 IAB counterpulsation may help to reduce CPB-induced gut mucosal hypoperfusion, thus avoiding intestinal ischemia and subsequent endotoxemia.

Today the IAB pump is the most widely used circulatory assist device. Improvement in its ease of insertion, safety, rapid applicability, and ability to provide adequate support in a low cardiac output syndrome has widened its use. IAB counterpulsation is an effective method of protecting the myocardium in the perioperative period and reducing organ dysfunction during CPB. However, as our survey revealed, the majority of cardiac surgeons in the United Kingdom do not fully use the benefits of IAB pulsatility during CPB. On the basis of available literature, we advocate continued counterpulsation during the whole of CPB.

References

  1. Torchiana DF, Hirsch G, Buckley MJ, et al. Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995. J Thorac Cardiovasc Surg 1997;113:758-69. [Abstract/Free Full Text]
  2. Creswell LL, Rosenbloom M, Cox JL, et al. Intraaortic balloon counterpulsation: patterns of usage and outcome in cardiac surgery patients. Ann Thorac Surg 1992;54:11-20. [Abstract]
  3. Dietl CA, Berkheimer MD, Woods EL, Gilbert CL, Pharr WF, Benoit CH. Efficacy and cost effectiveness of preoperative IABP in patients with ejection fraction of 0.25 or less. Ann Thorac Surg 1996;62:401-9. [Abstract/Free Full Text]
  4. Golding LAR, Loop FD, Peter M, Cosgrove DM, Taylor PC, Phillips D. Late survival following use of intraaortic balloon pump in revascularization operations. Ann Thorac Surg 1980;30:48-51. [Abstract]
  5. Bolooki H, Williams W, Thurer RJ, et al. Clinical and hemodynamic criteria for use of intraaortic balloon pump in patients requiring cardiac surgery. J Thorac Cardiovasc Surg 1976;72:756-68. [Abstract]
  6. Isom OW, Spencer FC, Feigenbaum H, Cunningham JCR. Prebypass myocardial damage in patients undergoing coronary revascularization: an unrecognized vulnerable period [abstract]. Circulation 1975;51(Suppl):II119.
  7. Pappas G, Winter SD, Kopriva CJ, et al. Improvement of myocardial and other vital organ functions and metabolism with a simple method of pulsatile flow (IABP) during clinical and cardiopulmonary bypass. Surgery 1975;77:34-44. [Medline]
  8. Hickey PR, Buckley MJ, Philbin DM. Pulsatile and nonpulsatile cardiopulmonary bypass: review of a counterproductive controversy. Ann Thorac Surg 1983;36:720. [Abstract]
  9. Taylor KM, Bain WH, Davidson KG, Turner MA. Comparative clinical study of pulsatile and nonpulsatile perfusion in 350 consecutive patients. Thorax 1982;37:324-30. [Abstract/Free Full Text]
  10. Kim SY, Euler DE, Jacobs WR, et al. Arterial impedance in patients during intraoperative balloon counterpulsation. Ann Thorac Surg 1996;61:888-94. [Abstract/Free Full Text]
  11. Phillips SJ, Zeff RH, Kongtahworn C, et al. Benefits of combined balloon pumping and percutaneous cardiopulmonary bypass. Ann Thorac Surg 1992;54:908-10. [Abstract]
  12. Gear JA, Shaw AD, Wild R, et al. Effect of cardiopulmonary bypass on gastrointestinal perfusion and function. Ann Thorac Surg 1994;57:371-5.[Abstract]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
F. Kawahara, Y. Kadoi, S. Saito, D. Yoshikawa, F. Goto, and N. Fujita
BALLOON PUMP-INDUCED PULSATILE PERFUSION DURING CARDIOPULMONARY BYPASS DOES NOT IMPROVE BRAIN OXYGENATION
J. Thorac. Cardiovasc. Surg., August 1, 1999; 118(2): 361 - 366.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Kurusz, S. D. Lick, and V. R. Conti
Air embolism with intraaortic balloon counterpulsation during cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., June 1, 1998; 115(6): 1393 - 1393.
[Full Text]


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mulay, A. V.
Right arrow Articles by Nair, R. U.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Mulay, A. V.
Right arrow Articles by Nair, R. U.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS