J Thorac Cardiovasc Surg 1998;115:958-959
© 1998 Mosby, Inc.
BRIEF COMMUNICATIONS |
St. Leonards, New South Wales, Australia
From the Cooperative Research Centre for Cardiac Technology, Block 4, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
Received for publication Sept. 10, 1997 Accepted for publication Oct. 7, 1997. Address for reprints: Dr. Melissa A. Bochner, c/o Professor S. N. Hunyor, Cooperative Research Centre for Cardiac Technology, Block 4, Level 3, Royal North Shore Hospital, St. Leonards, N.S.W., 2065, Australia.
Despite its use in clinical practice for more than 10 years, the operation of latissimus dorsi dynamic cardiomyoplasty still poses many unanswered questions regarding its efficacy, mechanism of action, and optimal management of the chronically paced skeletal muscle.
1 Whereas some investigators have described isolated postmortem changes in human studies
2 and single biopsy terminal results in animal studies,
3 the time course of histologic and histochemical changes in the latissimus dorsi muscle after cardiomyoplasty has not been documented. The ability to perform minimally invasive biopsy of the latissimus dorsi muscle wrap would both facilitate research in this area and potentially aid in the management of patients with poor hemodynamic status after cardiomyoplasty. We have therefore examined the applicability of thoracoscopic biopsy of the latissimus dorsi muscle after its use in cardiomyoplasty in the sheep.
The study was approved by the Animal Care and Ethics Committee of our institution, and animals received humane care in compliance with the "Principles of Laboratory Animal Care" formulated by the National Society for Medical Research and the "Guide for the Care and Use of Laboratory Animals" prepared by the Institute of Laboratory Animal Research and published by the National Institutes of Health (NIH Publication No. 86-23, revised 1985). All operations were performed with the animal under general anaesthesia. Latissimus dorsi cardiomyoplasty was performed on six sheep. A standard open technique through a left thoracotomy was used.
4 Baseline muscle biopsy specimens were taken at each procedure. The animals were nursed in a postoperative cage that allows invasive monitoring to continue until they are in a stable condition. Postoperative care included parenteral and enteral analgesia and prophylactic antibiotics.
Thoracoscopic biopsy specimens of the in situ latissimus dorsi wrap were taken 6, 12, and 18 weeks after the initial operation, with a total of 18 thoracoscopic procedures performed in the six months. Standard video-assisted thoracoscopy equipment was used (Smith & Nephew Endoscopy, Inc., Andover, Mass.), and all procedures were performed by means of two-lung ventilation. After the animal had been positioned on the right side, three left-sided port-access incisions were made for the camera (12 mm) and two operating ports (5 mm). Postoperative adhesions between the lung, diaphragm, and chest wall were carefully divided, and the left aspect of the pedicle and wrap were exposed. In each instance, the wrap was able to be assessed for position, contraction, and muscle bulk. By means of sharp dissection, and with minimal crushing of the tissue, biopsy specimens were taken from the proximal part of the muscle near the pedicle and from the midportion of the muscle. The mean sample weight was 134 mg (range 55 to 225 mg), and two samples were taken from each site at each procedure. Previous biopsy sites were able to be identified and avoided. With subsequent procedures, increased adhesion formation and the development of a capsule of fibrofatty tissue around the wrap was noted. Despite this, biopsy specimens of sufficient size (greater than 300 fibers) and quality to provide both complex histochemical data and tissue for protein analysis were able to be taken in all 18 procedures. Fig. 1 shows a representative thoracoscopic biopsy sample stained with myosin adenosinetriphosphatase at pH 4.7 (magnification x200).
|
In conclusion, we have found thoracoscopic biopsy to be a useful tool in the investigation of the changes occurring in the latissimus dorsi muscle after cardiomyoplasty. The procedure is well tolerated and is able to be performed sequentially in the same animal. There is potential for this technique to be used in further animal research and as an adjunct in the management of difficult clinical cases.
Acknowledgments
We acknowledge the technical assistance of Mr. R. Kearns, Ms. C. Philips, and Ms. J. Hardy.
References
This article has been cited by other articles:
![]() |
K. Shirota, O. Kawaguchi, Y. Huang, T. Yuasa, R. Carrington, P. W. Brady, and S. N. Hunyor Ventricular remodeling after cardiomyoplasty in heart failure sheep: passive and dynamic effects Ann. Thorac. Surg., December 1, 2000; 70(6): 2102 - 2106. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |