|
|
||||||||
J Thorac Cardiovasc Surg 1999;117:890-897
© 1999 Mosby, Inc.
SURGERY FOR ADULT CARDIOVASCULAR DISEASE |
From the Departments of Surgery and Medicine, Duke University Medical Center, Durham NC.
This study was funded in part by grants from St Jude Medical, Inc, and Baxter Healthcare Corp.
Received for publication Aug 26, 1998. Revisions requested Oct 5, 1998. Revisions received Jan 5, 1999. Accepted for publication Jan 5, 1999. Address for reprints: Donald D. Glower, MD; Box 3851, DUMC, Durham, NC 27710.
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
The purpose of this study was to examine the determinants of outcome after biologic versus mechanical aortic valve replacement as might be relevant in the selection of a biologic versus a mechanical prosthesis. Although many surgeons have agreed that younger and healthier patients should receive mechanical valves and older and sicker patients should receive bioprosthetic valves, a large difference in opinion exists as to the appropriate management of valvular disease in patients between ages 60 and 70 years who often have multiple comorbidities.
13 This retrospective analysis from one institution investigates whether the outcomes of patients who underwent aortic valve surgery differ with the use of mechanical versus bioprosthetic valves. An algorithm for prosthesis selection in patients with aortic valvular disease is proposed.
| Methods |
|---|
|
|
|---|
All aortic valve operations were performed through a median sternotomy with the use of cardiopulmonary bypass and crystalloid or blood cardioplegic solution. Patients with bioprostheses were generally started on long-term aspirin therapy beginning on the first postoperative day.
14 Patients with mechanical prostheses were started on warfarin sodium (Coumadin) therapy on postoperative day 2, either with or without aspirin therapy. Most patients with a mechanical valve were followed up by their local physicians to maintain an international normalized ratio of 2.0 to 3.0.
Outcomes were defined according to the standard definitions.
15 Renal disease was identified as a preoperative creatinine level greater than 2.0 mg/dL. Pulmonary disease included any ongoing pulmonary diagnosis requiring treatment. Coronary diameter reduction of 75% or more was considered to be significant. Endocarditis was defined as a clinical diagnosis of endocarditis. Valve-related morbidity was considered to be any hemorrhage, thromboembolism, aortic valve reoperation, or endocarditis. Perivalvular leak was defined as moderate or severe aortic regurgitation not the result of prosthetic dysfunction.
Data were analyzed with SAS software release 6.12 (SAS Institute, Cary, NC). Continuous data were expressed as mean ± SD. Comparisons of the 2 groups were made with the Mann-Whitney U test for continuous data not distributed normally. Cox proportional hazards regression model was used in the survival and valve-related outcome analysis. The assumptions of the proportional hazards model were checked graphically. The variables of age and ejection fraction were stratified or converted to binary form to accommodate a nonlinear relationship to risk. Variables were selected for models by a forward and backward stepwise elimination procedure. All univariable factors significant at P < .10 were examined. All the statistical analyses were conducted with
= .05. To obtain estimates of 10-year survival free of valve-related morbidity in selected age groups where several groups contained fewer than 10 patients, log curve fitting was used
16 (Fig. 1). Actual (versus actuarial) freedom from events was computed by the method of Grunkemeier and associates.
17 Kaplan-Meier curves were compared by the log rank test.
|
| Results |
|---|
|
|
|---|
|
2 = 8.2; P = .004) and concurrent coronary bypass grafting (
2 = 6.3; P = .01). Valve make (CE versus SJ prosthesis ) was not an independent predictor of 30-day mortality (
2 = 2.6; P = .10). Thus the higher 30-day mortality rate for patients with a CE versus an SJ prosthesis was largely attributable to the earlier year of operation for patients with a CE versus an SJ prosthesis and the improvement in operative mortality rate from 1976 to 1996.
Late survival
After aortic valve replacement, there was no significant difference in survival of patients receiving a CE versus an SJ prosthesis (54% ± 3% vs 50% ± 6% at 10 years; P = .4; Fig. 2). By Cox model analysis, independent multivariable factors predicting worse survival included older age, renal disease, ejection fraction less than 40%, lung disease, coronary artery disease, and diabetes (Table II). A CE versus an SJ make of valve (P = .4) and year of operation (P = .5) were not significant predictors of late survival by multivariable analysis. Causes of all deaths (early and late) were not significantly different (P = .8) between patients with a CE prosthesis and patients with an SJ prosthesis (Table III).
|
|
|
|
Ten-year freedom from endocarditis was not significantly different between patients with a CE prosthesis and patients with an SJ prosthesis (96% ± 1% vs 97% ± 1%; P = .5; Fig. 3
). By Cox model analysis, the only variable predictive of late endocarditis was preoperative endocarditis (ß = 2.3 ± .5;
2 = 20.5; P = .0001), and age did not significantly affect late endocarditis. The linearized rates of endocarditis were 0.4% ± 0.1%/pt-y for patients with a CE prosthesis and 0.4% ± 0.1%/pt-y for patients with an SJ prosthesis (P = .9).
Ten-year freedom from aortic valve reoperation was significantly better for patients with an SJ prosthesis (98% ± 1% vs 83% ± 3%; P = .02). By Cox model analysis, the only independent variables predictive of aortic valve reoperation were CE valve make (ß = 1.0 ± .4;
2 = 6.6; P = .01) and younger patient age (ß = .044 ± .009;
2 = 25.2; P = .0001). For patients over 65 years old, valve make did not affect aortic valve reoperation (P = .4, Fig. 4). For patients aged 65 years and younger, freedom from reoperation was significantly better for an SJ versus a CE prosthesis (P = .02; Fig. 4
). After reoperation, the 30-day mortality rate was 4 of 63 (6%) for all patients and 1 of 9 (11%) in all patients with coronary bypass grafting with the original aortic valve operation.
|
2 = 11.9; P = .0005), renal disease (
2 = 10.1; P = .002), diabetes (
2 = 8.2; P = .004), and coronary artery disease (
2 = 6.5; P = .01). For the entire pool of 841 patients, make of valve (CE vs SJ) and year of operation were not significant predictors of survival free from valve-related morbidity.
|
For patients not surviving 10 years, CE bioprostheses would be preferable because of the absence of anticoagulant-related hemorrhage and because of the rarity of reoperation within 10 years in these patients. Several groups of patients with a life expectancy less than 10 years (thus favoring bioprostheses) included patients over 65 years old, patients with lung disease who are under age 60 years, and patients at any age with renal disease, ejection fraction less than 40%, or coronary disease. Even in patients under 55 years old, the presence of coronary disease produced a 10-year survival of 35% ± 13% for patients with a CE prosthesis and patients with an SJ prosthesis combined. For patients in any of these groups who received a CE bioprosthesis, the actual 10-year freedom from aortic valve reoperation
15 was at least 95% (Table IV).
|
| Discussion |
|---|
|
|
|---|
|
The current study is the first to provide numeric data supporting guidelines to select biologic versus mechanical devices based on patient comorbidity other than age (Table IV). The current study provides data that support a specific age (65 years) over which survival free from valve-related events is better with biologic valves,
22,23 although outcome tended to be better with mechanical valves in younger patients (Table IV; Fig 1). Previous studies not examining comorbidities other than coronary disease have placed the cutoff for biologic versus mechanical prostheses at 65 to 70 years.
22,23 Patient selection bias (eg, patients with biologic valves having significantly less coronary disease) may explain why the Cleveland Clinic study showed better event-free survival with bioprostheses in patients over age 40 years.
21
The significantly higher incidence of early perivalvular leak rate in the SJ group has not been previously reported. Explanations for this finding may include differences in sewing ring width and shape between SJ and CE prostheses, along with the tendency to use SJ prostheses in smaller aortic roots where valve seating may be more difficult (Table I). SJ and other valve makes are now available with large sewing rings that were not used in this study.
The nonrandomized, retrospective nature of this study limits the findings. The major bias between the CE and SJ groups was the earlier year of operation and the resultant higher 30-day mortality in patients with a CE prosthesis. One possible effect of overestimating early deaths after CE aortic valve replacement may be to underestimate 10-year survival free from valve-related morbidity in patients with a CE prosthesis. In turn, this bias may mean that the CE and SJ curves in Fig. 1
actually should cross at age 65 years instead of age 70 years. These data therefore suggest that the age at which CE valves become advantageous is 65 years in this patient population.
An additional shortcoming of this study is the limited follow-up in the SJ group after 10 years, at which time differences between biologic and mechanical valves may be magnified by increased reoperation for structural deterioration of the bioprostheses. Fifteen-year data await further study; however, the conclusions of this study are based on 10-year results and are unlikely to be changed by data from the small number of patients surviving 15 years or more. Although the current study was limited to first-time isolated aortic valve procedures (with or without coronary bypass grafting), the results could well be different in patients with a previous cardiac operation or multiple valve operations.
10 Although this study is among the largest studies to date, the small patient numbers in some subgroups may have limited the ability to define ages where life expectancy could exceed 10 years and where results might therefore favor mechanical prostheses (eg, young patients with coronary disease; Table IV). In addition, the presence of previous coronary grafts in a young patient undergoing reoperation for a failed bioprosthesis could increase late mortality rates, although the reoperative mortality was a modest 11% for patients of all ages with previous coronary bypass grafts in the current study. The reported mortality rate for aortic valve operation has been 14% after previous coronary bypass
24 and as low as 8% after previous aortic valve replacement.
25
The current study evaluated a second generation porcine bioprosthesis that has been partly displaced by pericardial bioprostheses (models 2700 and 2800; Baxter Healthcare Corp). Yet, the study is still relevant because pericardial and porcine aortic prostheses have similar durability and performance characteristics.
26-29 The SJ valve (model A102) used in this study continues to be widely used.
30,31
Choice of an aortic bioprosthesis versus mechanical prosthesis should be individualized on the basis of the patient's ability to take warfarin and the patient's age and life expectancy. This choice primarily is one of increased likelihood of reoperation with bioprostheses versus increased likelihood of hemorrhage with mechanical prostheses. The relatively low 10-year survival of 50% to 54% and the high frequency of cardiac deaths (Table III) suggest that other factors, such as optimal timing of operation, may be more important to survival than prosthesis selection. The results of this study support the general philosophy that older, sicker patients tend to benefit more from bioprostheses and that younger, healthier patients should receive mechanical prostheses. Otherwise, patients who are unable to reliably take warfarin or who have medical illnesses precluding anticoagulation should receive a bioprosthesis.
The current study provides data that suggest age cutoff points for selecting biologic versus mechanical valves in different patient subgroups (Table IV; Fig 1). Patients with an expected survival of less than 10 years (more than 65 years old, renal disease, lung disease, patients who are more than 60 years old), ejection fraction of less than 40%, or coronary disease (Table IV; Fig 1) would be reasonable candidates for aortic bioprostheses to avoid anticoagulation with an extremely low likelihood of aortic valve reoperation (Table IV). Results tend to favor mechanical aortic valves in patients under age 65 years with a life expectancy of at least 10 years (Fig. 1
). Specific subsets of patients undergoing multiple valve operation or repeat cardiac operation merit further investigation.
10
| Appendix |
|---|
|
|
|---|
Valve type
Age older than 65 years
Sex
Ejection fraction less than 40%
Operation year
New York Heart Association heart failure class IV
Diabetes
Renal failure
Liver disease
Lung disease
Atrial fibrillation
Aortic regurgitation
Number of diseased coronary vessels
Peptic ulcer disease
Previous gastrointestinal hemorrhage
Endocarditis within 6 months
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. Guenzinger, W. B. Eichinger, I. Hettich, S. Bleiziffer, D. Ruzicka, R. Bauernschmitt, and R. Lange A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning? J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 462 - 471. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gudbjartsson, T. Absi, and S. Aranki Mitral Valve Replacement Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068. [Full Text] |
||||
![]() |
J. P. Greelish, R. M. Ahmad, J. M. Balaguer, M. R. Petracek, and J. G. Byrne Reoperative Valve Surgery Card. Surg. Adult, January 1, 2008; 3(2008): 1159 - 1174. [Full Text] |
||||
![]() |
M. Glauber, M. Solinas, and J. Karimov Technique for implant of the stentless aortic valve Freedom Solo MMCTS, October 18, 2007; 2007(1018): 2618. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ruel, V. Chan, P. Bedard, A. Kulik, L. Ressler, B. K. Lam, F. D. Rubens, W. Goldstein, P. J. Hendry, R. G. Masters, et al. Very Long-Term Survival Implications of Heart Valve Replacement With Tissue Versus Mechanical Prostheses in Adults <60 Years of Age Circulation, September 11, 2007; 116(11_suppl): I-294 - I-300. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lima, G. C. Hughes, A. Lemaire, J. Jaggers, D. D. Glower, and W. G. Wolfe Short-Term and Intermediate-Term Outcomes of Aortic Root Replacement with St. Jude Mechanical Conduits and Aortic Allografts Ann. Thorac. Surg., August 1, 2006; 82(2): 579 - 585. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ali, J. C. Halstead, F. Cafferty, L. Sharples, F. Rose, R. Coulden, E. Lee, J. Dunning, V. Argano, and S. Tsui Are Stentless Valves Superior to Modern Stented Valves?: A Prospective Randomized Trial Circulation, July 4, 2006; 114(1_suppl): I-535 - I-540. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Lund and M. Bland Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 20 - 26. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Chan, W.R.E. Jamieson, E. Germann, F. Chan, R.T. Miyagishima, L.H. Burr, M.T. Janusz, H. Ling, and G.J. Fradet Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15 years after aortic valve replacement J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1267 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Doss, J. P. Wood, S. Martens, G. Wimmer-Greinecker, and A. Moritz Do Pulmonary Autografts Provide Better Outcomes Than Mechanical Valves? A Prospective Randomized Trial Ann. Thorac. Surg., December 1, 2005; 80(6): 2194 - 2198. [Abstract] [Full Text] [PDF] |
||||
![]() |
I Florath, A Albert, U Rosendahl, T Alexander, I C Ennker, and J Ennker Mid term outcome and quality of life after aortic valve replacement in elderly people: mechanical versus stentless biological valves Heart, August 1, 2005; 91(8): 1023 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
J P A Puvimanasinghe, J J M Takkenberg, M B Edwards, M J C Eijkemans, E W Steyerberg, L A van Herwerden, K M Taylor, G L Grunkemeier, J D F Habbema, and A J J C Bogers Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation Heart, October 1, 2004; 90(10): 1172 - 1178. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. T. Smith IV, T. B. Ferguson Jr, T. Ryan, C. K. Landolfo, and E. D. Peterson Should coronary artery bypass graft surgery patients with mild or moderate aortic stenosis undergo concomitant aortic valve replacement?: A decision analysis approach to the surgical dilemma J. Am. Coll. Cardiol., September 15, 2004; 44(6): 1241 - 1247. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Sedrakyan, P. Hebert, V. Vaccarino, A. D. Paltiel, J. A. Elefteriades, J. Mattera, Z. Lin, S. A. Roumanis, and H. M. Krumholz Quality of life after aortic valve replacement with tissue and mechanical implants J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 266 - 272. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Borer and R. O. Bonow Contemporary Approach to Aortic and Mitral Regurgitation Circulation, November 18, 2003; 108(20): 2432 - 2438. [Full Text] [PDF] |
||||
![]() |
H Oxenham, P Bloomfield, D J Wheatley, R J Lee, J Cunningham, R J Prescott, and H C Miller Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses Heart, July 1, 2003; 89(7): 715 - 721. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Rahimtoola Choice of prosthetic heart valve for adult patients J. Am. Coll. Cardiol., March 19, 2003; 41(6): 893 - 904. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Byrne, T. Gudbjartsson, A. N. Karavas, T. Mihaljevic, B. J. Phillips, S. F. Aranki, J. D. Rawn, and L. H. Cohn Biological vs. mechanical aortic root replacement Eur. J. Cardiothorac. Surg., March 1, 2003; 23(3): 305 - 310. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Grunkemeier and Y. Wu "Our complication rates are lower than theirs": Statistical critique of heart valve comparisons J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 290 - 300. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gudbjartsson, S. Aranki, and L. H. Cohn Mechanical/Bioprosthetic Mitral Valve Replacement Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986. [Full Text] |
||||
![]() |
J. G. Byrne, B. J. Phillips, and L. H. Cohn Reoperative Valve Surgery Card. Surg. Adult, January 1, 2003; 2(2003): 1047 - 1056. [Full Text] |
||||
![]() |
C. W. Akins, A. D. Hilgenberg, G. J. Vlahakes, T. E. MacGillivray, D. F. Torchiana, and J. C. Madsen Results of bioprosthetic versus mechanical aortic valve replacement performed with concomitant coronary artery bypass grafting Ann. Thorac. Surg., October 1, 2002; 74(4): 1098 - 1106. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Y. Jin and J. R. Pepper Do stentless valves make a difference? Eur. J. Cardiothorac. Surg., July 1, 2002; 22(1): 95 - 100. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Bloomfield Choice of heart valve prosthesis Heart, June 1, 2002; 87(6): 583 - 589. [Full Text] [PDF] |
||||