JTCS Concomitant Website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Aquilino Hurlé
Juan Meseguer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hurlé, A.
Right arrow Articles by Llamas, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hurlé, A.
Right arrow Articles by Llamas, P.

J Thorac Cardiovasc Surg 1999;118:197-199
© 1999 Mosby, Inc.


BRIEF COMMUNICATIONS

STENT FRACTURE IN A CARPENTIER-EDWARDS SUPRA-ANNULAR PORCINE BIOPROSTHESIS IMPLANTED IN THE MITRAL POSITION

Aquilino Hurlé, MD, Juan Meseguer, MD, Juan A. Casillas, MD, Jesús Gómez-Plana, MD, Patricio Llamas, MD, Alicante, Spain

From the Department of Cardiac Surgery, Hospital General Universitario de Alicante, Alicante, Spain.

Address for reprints: Aquilino Hurlé, MD, Servicio de Cirugía Cardiaca, Hospital General Universitario de Alicante. C/Pintor Baeza s/n, E-03010 Alicante, Spain.

Bioprosthetic heart valve dysfunction resulting from deterioration of its supportive stent is uncommon. Permanent inward deformation of the stent posts ("stent creep"), a phenomenon known to occur in some bioprosthetic models as the result of valve oversizing, may lead to intrinsic valve stenosis.Go 1 However, total disruption of the stent leading to valve dysfunction is rare, with only few reports being available in the literature.

Clinical summary
We report the case of a 55-year-old man who underwent mitral valve replacement with a size 33 mm Carpentier-Edwards supra-annular porcine bioprosthesis (Baxter Healthcare Corp, Edwards Division, Santa Ana, Calif) for rheumatic heart valve disease in 1987. Apart from this, his medical history revealed no other relevant data. He remained free of symptoms until October 1997, when he started having shortness of breath. In December 1997 he was admitted to our hospital on an emergency basis with grade IV dyspnea and peripheral edema. A chest x-ray film showed a pattern of pulmonary edema and a double fracture in the wire stent of the mitral prosthesis (Fig. 1). Echocardiography revealed moderate regurgitation of the aortic valve, mitral prosthesis, and tricuspid valve. Cardiac catheterization confirmed these findings and demonstrated moderate impairment of left ventricular function, as well as a pulmonary artery pressure of 107/50 mm Hg (mean 69 mm Hg). He was initially treated with captopril and diuretics with good response, and surgery was indicated. The patient underwent mitral and aortic valve replacement with St Jude Medical mechanical devices (sizes 33 mm and 25 mm, respectively; St Jude Medical, Inc, St Paul, Minn) and tricuspid annuloplasty. The macroscopic examination of the explanted mitral bioprosthesis disclosed moderate tissue mineralization and a severe inward deformity of one of its stent posts, causing the prolapse of an adjacent cusp (Fig. 2). His postoperative course was complicated by postperfusion vasoplegic shock unresponsive to treatment, resulting in rapidly progressing multiorgan failure that led to his death in the intensive care unit on the second postoperative day.



View larger version (124K):
[in this window]
[in a new window]
 
Fig 1. Detailed view of the pre-explantation lateral chest radiograph showing two fractures (arrows) in the wire frame of the mitral bioprosthesis.

 


View larger version (105K):
[in this window]
[in a new window]
 
Fig 2. Explanted bioprosthesis. A notorious inward deformity in one of its stent posts with protrusion of the fractured wire can be observed (arrow).

 
Discussion
Stent disruption is an extraordinarily uncommon mode of structural deterioration in bioprosthetic heart valve substitutes. For this reason, the data available in the literature on this subject are very limited. The compliant metal frame of Carpentier-Edwards bioprostheses is manufactured with Elgiloy, a corrosion-resistant alloy of cobalt and nickel (Elgiloy Limited Partnership, Elgin, Ill) that was chosen for its spring efficiency and its fatigue-resistant characteristics. To our knowledge, only one case of a mitral Carpentier-Edwards bioprosthesis malfunctioning as the result of fracturing of its Elgiloy wire frame has been previously reported.Go 2 Most of the data available on this complication refer to the experience achieved with the Wessex porcine bioprosthesis,Go Go 3-5 a device no longer available for clinical use, in which the fracture of the acetyl copolymer stent was a common mode of deterioration.Go 5

The mechanisms responsible for the occurrence of such fractures, which are often multiple in the affected devices,Go 5 are uncertain. Computer-based studies on the Delrin stent of Hancock II porcine bioprostheses (Medtronic, Inc, Minneapolis, Minn) have identified the bases of the commissural arches of the frame as areas supporting high mechanical stresses.Go 6Fractures have a tendency to occur in these particular areasGo Go 2-5 and, on these grounds, one can speculate that this phenomenon could be due to mechanical fatigue of the stent materials in areas of increased stress. This theory would also be supported by the fact that clinically relevant stent fractures are more common in valves implanted in the mitral position (where prosthetic frames must withstand greater static and dynamic stresses owing to the physiologic tridimensional dynamics of the native mitral anulus) than in those implanted at other sites.Go Go 2-5

Clinical presentation is in the form of valve regurgitationGo Go 2-5 which, in our patient, occurred in a subacute manner 11 years after implantation. However, the reported experience with explanted Wessex bioprosthesesGo 5 suggests that valves with fewer than two fractures (as often occurs with devices implanted in the aortic position) have only a modest risk of deformation. In these cases, the valves may be functioning normally and, thus, the ruptured stent may be unnoticed by the observing physician and even by the explanting surgeon.

Clinical screening of fractures in the wire stent of Carpentier-Edwards bioprostheses is simple because their metal radiopaque frame can be easily visualized with a conventional chest radiograph, as illustrated by Fig. 1Go. However, the detection of such complication in patients having bioprosthetic devices with radiolucent frames may be more difficult. Echocardiography would probably be the diagnostic method of choice in these cases.

We believe that conservative management with a close follow-up is probably the best line of action so long as the valve continues to function normally. However, if a serious deformity of the device is observed, particularly if there is any clinical evidence of valve dysfunction, replacement surgery should be considered.

References

  1. Schoen FJ, Schulman LJ, Cohn LH. Quantitative anatomic analysis of "stent creep" of explanted Hancock standard porcine bioprostheses used for cardiac valve replacement. Am J Cardiol 1985;56:110-4. [Medline]
  2. Griffin S, Bouboulis N, Holden MP. Fracture of the wire stent in a Carpentier-Edwards porcine bioprosthesis. J Heart Valve Dis 1993;2:357-8. [Medline]
  3. Au J, Campanella C. Mitral prosthetic valve regurgitation due to stent fracture in a porcine bioprosthesis. Thorax 1989;44:236-7. [Abstract/Free Full Text]
  4. Ius P, Valente M, Thiene G. Nonfatal stent fracture in porcine Wessex xenografts implanted in the mitral position. Am J Cardiol 1996;78:972-3. [Medline]
  5. Hurlé A, Nistal JF, Revuelta JM. Stent fracture in Wessex porcine heart valve bioprostheses. Artif Organs 1997;21:116-20. [Medline]
  6. Wright JTM, Eberhardt CE, Gibbs ML, Saul T, Gilpin CB. Hancock II: an improved bioprosthesis. In: Cohn LH, Gallucci V, editors. Cardiac bioprostheses. Proceedings of the Second International Symposium. New York: Yorke Medical Books; 1982. p. 425-44.
Received for publication Feb 22, 1999. Accepted for publication March 8, 1999.



This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Aquilino Hurlé
Juan Meseguer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hurlé, A.
Right arrow Articles by Llamas, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hurlé, A.
Right arrow Articles by Llamas, P.