JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
K. Minami
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hornik, L.
Right arrow Articles by Koerfer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hornik, L.
Right arrow Articles by Koerfer, R.
Related Collections
Right arrow Coronary disease
Right arrow Minimally invasive surgery

J Thorac Cardiovasc Surg 2003;125:414-417
© 2003 The American Association for Thoracic Surgery


Brief Communications

First experience with the St Jude Medical, Inc, Symmetry Bypass System (Aortic Connector System)

L. Hornika, G. Tendericha, K. Minamia, D. Fassbenderb, T. O. Schulza, B. Beinerta, R. Koerfera Bad Oeynhausen, Germany

From the Department of Thoracic and Cardiovascular Surgerya and the Department of Cardiology,b Heart Center North Rhine-Westfalia, Ruhr-University of Bochum, Bad Oeynhausen, Germany.

Received for publication April 3, 2002. Accepted for publication May 30, 2002. Address for reprints: Lech Hornik, Heart Center North Rhine-Westphalia, Department of Thoracic and Cardiovascular Surgery, Georgstrasse 11, Bad Oeynhausen North Rhine-Westphalia 32545, Germany.



View larger version (117K):
[in this window]
[in a new window]
 
Tenderich and Hornik (left to right).

 
Using the saphenous vein graft in coronary artery bypass grafting, the proximal anastomosis is usually performed by running sutures with a partial occlusion clamp. This technique is bearing the risk of immediate or delayed aortic dissection induced by the heel of a partial occlusion clamp,Go 1 especially in the case of a diseased aortic wall or poor suturing technique.

If atheroma or calcification of the aortic wall are present, clamping is often impossible, and it remains unclear whether the use of the partial occlusion clamps on the pulsating aorta during off-pump surgery will increase the risk of iatrogenic injuries.

However, the St Jude Medical, Inc, Symmetry Bypass System (Aortic Connector System [ACS]) presents an alternative way of creating the proximal anastomosis of saphenous vein grafts.Go 2 It avoids aortic bite clamping and reduces the need for aortic manipulation.

Patients and methods

Between April and October 2001, 69 of 70 proximal anastomoses were consecutively performed in 45 patients aged 36 to 89 years (mean, 68.3 years) by using the ACS. Eighteen internal thoracic artery grafts, 70 autologous vein grafts, and 1 radial artery graft were used, for a total number of 108 peripheral anastomoses with an average of 2.4 anastomoses per patient. Five patients were operated on in a conventional manner with the heart-lung machine. Of 31 off-pump patients, 9 patients had to be switched to on-pump therapy, with a conversion rate of 29%.

In 4 patients with postoperatively de novo angina pectoris, coronary angiography was indicated, showing severe stenosis of the proximal anastomoses in each case.

In all cases the stenosis appeared several weeks after discharge from the hospital. Three patients underwent a redo procedure using the heart-lung machine and partial occlusion clamp, and one patient was treated by means of dilatation.

Patient 1
A 52-year-old woman had a history of dialysis since 1998 and 3-vessel disease. Preoperatively, she was treated with nitrate and heparin because of unstable angina pectoris after 2 fruitless attempts at angioplasty of the right coronary artery (RCA). There was no myocardial infarction. Ejection fraction was 74%. Elective on-pump coronary artery surgery was performed on June 28, 2001, and indication for use of the ACS was a severe calcified ascending aorta. Two single-vein grafts to the left anterior descending coronary artery (LAD) and the posterior descending coronary artery (PDA) were placed. A short time after discharge, the patient had angina pectoris. Cardiac catheterization (September 19, 2001) showed an occlusion of the PDA bypass next to the stenosed proximal ACS anastomosis (Figure 1), as well as a subtotal stenosis of the proximal anastomosis of the ACS-LAD graft (Figure 2). On September 21, the patient had an acute inferior myocardial infarction and a maximum creatine kinase level of 400 U/L. Redo surgery was performed successfully on October 18, 2001, in a conventional manner by using cardiopulmonary bypass and placing 2 single-vein grafts to the RCA and the marginal branch of the circumflex artery, as well as the left internal thoracic artery to the LAD. Histopathologic examination of the proximal parts of the explanted PDA bypass showed severe intimal fibrosis, as well as organized and partially revascularized thrombosis.



View larger version (139K):
[in this window]
[in a new window]
 
Fig. 1. Occlusion of the saphenous vein graft to the posterior descending coronary artery next to the stenosed proximal ACS anastomosis.

 


View larger version (160K):
[in this window]
[in a new window]
 
Fig. 2. High-grade stenosis of the proximal vein graft anastomosis to the LAD performed with the ACS.

 
Patient 2
A 47-year-old woman was given a diagnosis of 2-vessel disease. She had a history of myocardial infarction, but her ejection fraction was normal. The operation was performed on April 24, 2001, placing 2 single-vein grafts to the RCA and diagonal branch (Dg) by means of off-pump coronary surgery with the ACS. The postoperative course was without any complications until September 2001, when the patient again had angina pectoris. Cardiac catheterization showed a severe stenosis of the proximal anastomosis of both vein grafts (Figures 3 and 4), and redo surgery was performed successfully on September 20, 2001, placing 2 single-vein grafts to the PDA, as well as to the Dg, in the conventional method with a heart-lung machine and partial clamping.



View larger version (152K):
[in this window]
[in a new window]
 
Fig. 3. High-grade stenosis of the proximal vein graft anastomosis to the RCA related to the ACS.

 


View larger version (168K):
[in this window]
[in a new window]
 
Fig. 4. Stenosis of the proximal anastomosis of the saphenous vein graft to the Dg performed with the ACS.

 
Patient 3
A 57-year-old man given a diagnosis of 2-vessel disease underwent off-pump coronary surgery, placing one sequential vein graft to the Dg and to the proximal as well as the distal part of the LAD (snake graft) on June 9, 2001, with the ACS. The postoperative course was uneventful, and the patient was discharged 6 days after surgical treatment.

At the end of 2001, he again had angina pectoris, and cardiac catheterization showed a high-grade stenosis of the proximal (Figure 5) and peripheral anastomosis. Redo surgery was successfully performed on January 7, 2002, by using cardiopulmonary bypass and partial occlusion clamping.



View larger version (139K):
[in this window]
[in a new window]
 
Fig. 5. High-grade stenosis of the proximal anastomosis of the sequential LAD-Dg vein graft related to the ACS.

 
Patient 4
A 78-year-old man was given a diagnosis of 2-vessel disease, and he had an ejection fraction of 24%. Preoperatively, the patient reported unstable angina pectoris. Coronary surgery was performed on April 4, 2001, by using conventional cardiopulmonary bypass. A sequential vein graft was placed to the Dg and LAD by using the ACS for severe calcification of the aorta. A further single graft was placed to the marginal branch of the circumflex artery with a venovenous anastomosis to the LAD-Dg graft. A short time after discharge, he again had angina pectoris. Cardiac catheterization showed a high-grade stenosis of the LAD-Dg graft proximal to the venovenous anastomosis (Figure 6). Successful dilatation and stenting of the stenosis was done on June 13, 2001. In December 2001, the patient was admitted again because of recurrent unstable angina pectoris. Cardiac catheterization showed a high-grade stenosis of the proximal anastomosis of the LAD-Dg graft related to the ACS (Figure 7), which was dilated and stented successfully on December 7, 2001.



View larger version (121K):
[in this window]
[in a new window]
 
Fig. 6. High-grade stenosis of the LAD-Dg graft in the middle part of the bypass proximal to venovenous anastomosis.

 


View larger version (124K):
[in this window]
[in a new window]
 
Fig. 7. Stenosis of the proximal anastomosis of the LAD-Dg graft related to the ACS.

 
Discussion

Using a partial occlusion clamp for proximal anastomosis in aorta-coronary bypass surgery bears the risk of iatrogenic dissections or embolic complications for various reasons. These complications are more likely in patients with the risk factors of atheroma, calcification, medial necrosis, a thin fragile aorta, or an increased wall tension during off-pump surgery.Go 1 St Jude Medical, Inc, offers a novel sutureless connector system for creation of the proximal anastomosis of saphenous vein grafts without the need for clamping of the aorta.Go 2 The vein hook is made of nickel titanium (Nitinol), a biocompatible alloy, and published results show that the ACS does not seem to impair endothelial function.*

However, 4 of 45 patients treated with the ACS between April 2001 and October 2001 had a proximal ACS-related stenosis, thrombosis of the saphenous vein graft, or both, with the need for reintervention within 6 months postoperatively. One resected vein graft showed a partially revascularized thrombosis of the proximal graft. Genesis of the stenoses is unknown. We did not observe any kinking of any of the implanted grafts at the aortic take-off point as a probable cause. A possible explanation could be the unavoidable learning curve, resulting in an undersizing or oversizing or the incomplete piercing of the saphenous vein, followed by rolling up of the intima and resulting thereby in graft stenosis or occlusion, mechanical alteration of the intima itself, or bioincompatibility of the device. The significance of the ACS in the genesis of proximal graft stenosis, thrombosis, or both has to be elucidated by means of further investigations.

Footnotes

*Verma S, Ko L, Fedak PWM, Cusimano RJ, Yau T. The St Jude Medical sutureless aortic anastomotic connector does not impair endothelial function in human saphenous veins. Unpublished data. Back

References

  1. Hagl C, Ergin A, Galla JD, Spielvogel D, Lansman S, Squiteri RP, et al. Delayed chronic type A dissection following CABG. J Card Surg. 2000;15:362-7.[Medline]
  2. Eckstein FS, Bonilla LF, Engelberger L, Stauffer E, Berg TA, Schmidli J, et al. Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses. Ann Thorac Surg. 2001;72:S995-8.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Takemura, Y. Fukumoto, T. Miyauchi, K. Shimabukuro, M. Imaizumi, and N. Ishida
Easy Technique for Mounting the Heartstring System into the Sheath
Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 444 - 445.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Bergmann, K. Meszaros, S. Huber, P. Oberwalder, H. Machler, G. Schaffler, R. Rienmueller, and B. Rigler
Forty-one-month follow-up of the Symmetry aortic connector system for proximal venous anastomosis
J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 23 - 28.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Kitamura, H. Okabayashi, M. Hanyu, Y. Soga, T. Nomoto, H. Johno, J. Nakano, T. Matsuo, M. Kai, and E. Umehara
Early and midterm patency of the proximal anastomoses of saphenous vein grafts made with a Symmetry Aortic Connector System
J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 1028 - 1031.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Melero, C. Porras, M. Such, E. Olalla, and J. Alonso
Severe Stenosis of Anastomoses by Using the Symmetry Aortic Connector System
Ann. Thorac. Surg., November 1, 2004; 78(5): 1831 - 1833.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. Reuthebuch, A. Kadner, and M. I. Turina
Reply
Ann. Thorac. Surg., November 1, 2004; 78(5): 1878 - 1879.
[Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Kitamura, H. Okabayashi, M. Hanyu, J. Nakano, S. Kono, T. Nomoto, A. Nagasawa, H. Sakaguchi, H. Johno, and T. Matsuo
Early Results and Problems with St. Jude Medical Symmetry Bypass System in Japan
Asian Cardiovasc Thorac Ann, September 1, 2004; 12(3): 236 - 238.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Redaelli, F. Maisano, G. Ligorio, E. Cattaneo, F.M. Montevecchi, and O. Alfieri
Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis
J. Thorac. Cardiovasc. Surg., July 1, 2004; 128(1): 117 - 123.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Lahtinen, F. Biancari, M. Mosorin, J. Heikkinen, P. Rainio, T. S. Juvonen, and M. Lepojarvi
Fatal complications after use of the symmetry aortic connector in coronary artery bypass surgery
Ann. Thorac. Surg., May 1, 2004; 77(5): 1817 - 1819.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Reuthebuch, A. Kadner, M. Lachat, A. Kunzli, U. P. Schurr, and M. I. Turina
Early bypass occlusion after deployment of Nitinol connector devices
J. Thorac. Cardiovasc. Surg., May 1, 2004; 127(5): 1421 - 1426.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. C. Anyanwu
Authors should list confounding factors and alternative explanations for adverse events seen with new technologies
J. Thorac. Cardiovasc. Surg., November 1, 2003; 126(5): 1663 - 1664.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
K. Minami
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hornik, L.
Right arrow Articles by Koerfer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hornik, L.
Right arrow Articles by Koerfer, R.
Related Collections
Right arrow Coronary disease
Right arrow Minimally invasive surgery


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS