|
|
||||||||
J Thorac Cardiovasc Surg 2004;127:1688-1696
© 2004 The American Association for Thoracic Surgery
Surgery for congenital heart disease |
a Clinic for Cardiovascular Surgery,University Hospital, Bern, Switzerland
b Division of Pediatric Cardiology,University Hospital, Bern, Switzerland
c Division of Cardiovascular Anesthesiology, University Hospital, Berne, Switzerland
Received for publication April 30, 2003; revisions received November 27, 2003; accepted for publication January 21, 2004.
* Address for reprints: Pascal A. Berdat, MD, Clinic for Cardiovascular Surgery, Swiss Cardiovascular Center Berne, University Hospital, CH-3010 Berne, Switzerland
pascal.berdat{at}insel.ch
| Abstract |
|---|
|
|
|---|
METHODS: Forty-one children younger than 5 years were prospectively randomized to groups A (polyamid filter with conventional ultrafiltration), B (polyamid filter with modified ultrafiltration), C (polysulfon filter with conventional ultrafiltration), and D (polysulfon filter with modified ultrafiltration). Interleukin 6, interleukin 10, tumor necrosis factor, terminal complement complex, and lactoferrin were measured before the operation (T0), before rewarming (T1), after ultrafiltration (T2), at 6 (T3) and 18 hours (T4) after the operation, and in the ultrafiltrate.
RESULTS: All markers changed with both ultrafiltration methods, both filter types, and in all groups (except tumor necrosis factor) along the T0 to T4 observation time (P < .0001). Their patterns of changes were different for terminal complement complex, with less decrease after use of the polysulfon filter (P < .05), and among groups A through D for interleukin 6 (P = .01), with more decrease in group C than group A (P < .02). Interleukin 10 decreased with the polyamid filter (P < .001) but not with the polysulfon filter. In the ultrafiltrate, tumor necrosis factor was higher with the polysulfon filter than the polyamid filter (6.8 ± 5 pg/mL vs 4.0 ± 3.7 pg/mL, P < .05). The ultrafiltrate/plasma ratio of interleukin 6 was higher with conventional ultrafiltration than modified ultrafiltration (0.018 ± 0.017 vs 0.004 ± 0.007, P < .005).
CONCLUSIONS: The polysulfon filter showed a filtration profile for inflammatory mediators superior to that of the polyamid filter for interleukin 6, tumor necrosis factor, and interleukin 10. Interleukin 6 was most efficiently removed by conventional ultrafiltration with a polysulfon filter, and tumor necrosis factor was best removed by modified ultrafiltration with a polysulfon filter, whereas other inflammatory mediators were not influenced by filter type or ultrafiltration method. Therefore combined conventional and modified ultrafiltration with a polysulfon filter may currently be the most effective strategy for removing inflammatory mediators in pediatric heart surgery.
|
The proinflammatory response to cardiac surgery, induced by the production of cytokines triggered by cardiopulmonary bypass (CPB),1-3 contributes significantly to postoperative morbidity and mortality4 and is accentuated in pediatric patients.5,6 With ultrafiltration, most of the excess free water and a part of these mediators may be eliminated, and the inflammatory response to CPB thus may be attenuated.4,7 Conventional ultrafiltration (CUF), applied during the rewarming phase on CPB, and modified ultrafiltration (MUF), performed immediately after cessation of CPB, are both broadly used in pediatric cardiac surgery.8-11However, conflicting data exist concerning their efficacy in removing cytokines,4-6,9,12-15 and controversy has mainly focused on differences in ultrafiltration methods but not in filter performance. Additionally, comparison of results from ultrafiltration studies are difficult because of variations in ultrafiltration techniques, equipment, definitions of study end points, and cytokine measurements. Since 1973 different types of hemofilters, mainly polycarbon, have been used to eliminate the excess water from the priming volume according to the pressure gradient principle. These filters have permanently been improved, replaced by polyarylethersulfon filters (PSF) in 1986 and later by the most recent filter generation, the polyamid filter (PAF). PSF does not have ideal filtration properties, because high pressure gradients are needed and filtration rates can be controlled only approximately. The improved biocompatibility of the PAF, along with its reduced surface, effectiveness of filtration under physiologic pressure, and excellent handling properties, makes its use for ultrafiltration attractive. The efficacy of these filters in removing inflammatory mediators, simultaneously taking into consideration different ultrafiltration methods, has not however been investigated in a direct comparative fashion so far. To optimize efficacy of ultrafiltration, methods and filter types need be harmonized, combining a particular ultrafiltration method with a specific filter type, to allow more efficient elimination of cytokines. The aim of this study was to assess the effectiveness of PSF and PAF filters concerning elimination of cytokines in relation to the ultrafiltration method used. Secondarily, we wanted to define an optimal combination of filter type and ultrafiltration method in pediatric cardiac surgery.
| Patients and methods |
|---|
|
|
|---|
|
Anesthesia
All patients were given midazolam (Dormicum; Roche Pharma AG, Reinach, Switzerland) at 0.5 to 1 mg/kg rectally for premedication. Anesthesia was induced with thiopental (Pentothal; Abbott AG, Baar, Switzerland) with midazolam or ketamine (Ketalar; Pfizer AG, Zurich, Switzerland) with midazolam and continued with high-dose fentanyl (Fentanyl-Jansson; Janssen-Cilag AG, Baar, Switzerland) and isoflurane (Forene; Abbott AG) or ketamine infusion of 2 mg/kg. Muscle relaxation was achieved with pancuronium (Pavulon; Organon AG, Pfäffikon, Switzerland). Patients were mechanically ventilated with mixed air and oxygen (40%-50%) and extubated in the intensive care unit. Hemodynamics were routinely assessed by transesophageal echocardiography and surgical introduction of a pulmonary artery pressure catheter. For postoperative pain relief, patients were given morphine (Morphin-HCl; Sintetica SA, Mendrisio, Switzerland) supplemented with acetaminophen (INN: paracetamol, Dafalgan; UPSAmedica GmbH, Baar, Switzerland). Patients received antibiotic prophylaxis with intravenous cefuroxime at 50 mg/kg and continued at 100 mg/(kg · d) (Zinacef; GlaxoSmithKline AG, Münchenbuchsee, Switzerland) for at least 24 hours until all drains were removed.
Blood sample protocol
Blood samples for analysis of cytokine concentrations were collected from the radial artery after induction of anesthesia (T0), before rewarming (T1), after ultrafiltration (T2), at 6 (T3) and 18 hours (T4) after the operation. Blood was collected into sterile ethylenediaminetetraacetic acid and serum tubes and immediately centrifuged at 2000g for 15 minutes at 6°C. Plasma, ultrafiltrate, and urine samples were stored in multiple aliquots at 70°C until analysis and were thawed only once. At each time point the hematocrit was measured.
Ultrafiltration technique
CUF was started with rewarming until cessation of CPB and was stopped after complete extraction of the priming volume. During MUF, the aortic cannula was used to drain the blood across the filter and one atrial cannula was used to return the filtered blood without an auxiliary blood pump. Thus MUF was passively driven by the gradient between aorta and right atrium and assisted by application of vacuum (approximately 20 cm H2O) at the ultrafiltrate outlet port of the filter. CPB was bypassed by this ultrafiltration circuit, and therefore only the patient volume was filterable. MUF was started after cessation of CPB, as soon as the child was hemodynamically stable, and performed for a period of 20 minutes. During aortic crossclamping, hemofiltration was performed to eliminate 50% of the priming volume, and during CUF or MUF, the residual 50% was eliminated. The volume filtered was replaced 1:1 with packed red blood cells until a hematocrit of 30% was reached; thereafter, it was replaced with fresh-frozen plasma. In groups A and B, a PAF (Jostra BC20 Blood Concentrator filter; Jostra Medizintechnik AG, Hirrlingen, Germany) with a surface of 0.2 m2, a priming volume of 13 mL, a maximal transmembranous gradient of 600 mm Hg, a luminal diameter of 22 µm, and a membrane thickness of 50 µm was used. In groups C and D, a PSF (Jostra BC60 Blood Concentrator filter; Jostra Medizintechnik AG) with a surface of 0.65 m2, a priming volume of 55 mL, a maximal transmembranous gradient of 600 mm Hg, a luminal diameter of 215 µm, and a membrane thickness of 50 µm was used.
Cytokine and complement analyses
Interleukin (IL) 6, IL-10, and tumor necrosis factor
(TNF) were measured with specific enzyme immunoassays (Pierce Endogen, Rockford, Ill). To estimate activation of the complement system, we chose the terminal soluble C5b-9 complement complex (TCC) to reflect effector consequence of all three activation pathways (classical, alternative, and mannose-binding protein). TCC was also measured by enzyme immunoassay (Quidel, Mountain View, Calif), as was lactoferrin (Oxis International, Inc, Portland, Ore). All enzyme immunoassays were performed according to the recommendations of the manufacturers. All cytokine concentrations (except those of the ultrafiltrate) were corrected for the actual hematocrit to correct for the high variability of hemodilution. Values measured below the detection limit of a specific test were set equal to the lower limit for statistical analysis.
Statistics
Data are expressed as mean ± SD. Percentages are given where appropriate. Statistical analysis was performed with Statview 5.0.1 for Windows (SAS Institute Inc, Cary, NC). For continuous variables comparing serial values, repeated-measures analysis of variance was used. For within-group and between-group analyses, a Mann-Whitney U test and a Fisher exact test were used, respectively. Bonferroni correction was applied where appropriate.
| Results |
|---|
|
|
|---|
Inflammatory markers
All inflammatory markers except TNF showed a marked increase during surgery (IL-6, IL-10, TCC) or in the first 6 hours thereafter (IL-6, lactoferrin), with return to baseline levels within 18 hours except for lactoferrin.
Repeated-measures analysis of variance (Figure 1, A-E) revealed no significant effect of the ultrafiltration method (CUF vs MUF) on IL-6, IL-10, TNF, lactoferrin, and TCC. Plasma concentrations of all inflammatory markers changed significantly with both ultrafiltration methods along the T0 to T4 observation time (P < .0001), but the patterns of changes of all markers were not different between the ultrafiltration methods. Testing the effect of the filter type (PAF vs PSF) showed no significant difference regarding IL-6, IL-10, TNF, and lactoferrin. Plasma concentrations of all inflammatory markers changed significantly with both filter types along the T0 to T4 observation time (P < .0001), but the patterns of changes of all markers were not different between the filter types. With the use of PSF, TCC showed a significantly different changing pattern than with PAF (P < .05), with less decrease after filtration (Figure 1, D, Table 2). Testing the effect of the 4 combinations of filter type and ultrafiltration method on IL-6, IL-10, TNF, lactoferrin, and TCC revealed no significant differences among groups A through D. All markers except TNF changed significantly along the T0 to T4 observation time (P < .0001). Only the patterns of changes of IL-6 (Figure 1, A) were significantly different among groups A through D (P = . 01), especially between A and C (P < .02).
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
Overall, there was little difference between the two ultrafiltration methods concerning their efficacy to remove inflammatory mediators from the blood. We found that the ultrafiltration method itself was responsible for a measurable difference for IL-6, TNF, TCC, and lactoferrin. IL-6 plasma levels were significantly lower at the end of CUF than both after MUF and after CUF with PSF. Accordingly, the ultrafiltrate/plasma ratio of IL-6 was significantly higher in the CUF group C than in the MUF groups B and D and was higher with CUF than with MUF, indicating better elimination of IL-6 with CUF than with MUF. Thus, IL-6 was removed to a significantly higher degree from the blood with CUF than with MUF, especially when combined with a PSF filter type, although no relevant differences in total amount of IL-6 filtered were found among the groups. These findings are similar to those of Wang and coworkers,15 who also found lower plasma IL-6 concentrations after CUF than MUF with PSF but without a higher ultrafiltrate/plasma ratio of IL-6. They also found TNF to be more efficiently eliminated with MUF. Theoretically it would be more appealing to eliminate the inflammatory mediators by CUF during rewarming, the moment of their maximal release.5,20 In accordance with Journois and coworkers, who found IL-6 and TNF significantly lowered with CUF and PSF in their first study6 and IL-6, TNF, IL-10, and C3a better eliminated with combined zero-balanced CUF and MUF than MUF alone with a polynitril filter in their second study,4 our findings suggest no uniform advantage of one ultrafiltration method with respect to the other concerning cytokine removal. Nevertheless, elimination of IL-6 may be of prognostic importance, because Hauser and coworkers21 showed that elevated IL-6 plasma levels 2 hours after CPB correlated significantly with postoperative morbidity and mortality. Although TCC was lower after CUF and lactoferrin was lower after MUF, both their concentrations in the ultrafiltrate were extremely low, suggesting poor filtration. Even though filtered quantities of proinflammatory markers have mostly been small in other studies as well,5,13,15 ultrafiltration is able to reduce their plasma concentrations after the operation and exert a modifying effect on the inflammatory response to CPB.9,15,22,23
Analysis of ultrafiltration efficacy in the literature has focused mainly on different ultrafiltration methods. But these various ultrafiltration methods may exert only a modest influence on cytokine elimination, which instead shows significant correlation with duration of filtration,6 and on clinical outcome, which depends more on the amount of fluid filtered than the ultrafiltration strategy being used.14 Instead, efficacy of ultrafiltration may depend on the properties of the filter type in use, which may differ considerably in their performance of solute removal and clearance of molecules. These differences are at least in part explained by the physical characteristics of the membrane used (pore diameter and electrostatic surface), which may inhibit cytokines to be passively filtered together with plasma water along a pressure gradient across the semipermeable membrane. Generally, smaller molecules such as IL-6,6,13,15 IL-8,9,15 TNF,6,13,15 C3a or C5a,4-6 and endothelin 111,17 have been shown to be filtered with ultrafiltration. However, the efficacy of removal of different molecules from the circulation by ultrafiltration may be explained not only by their molecular weights but also by different molecular conformations and formation of complexes with physiologic soluble inhibitors.14 Furthermore, with ultrafiltration substances are not necessarily removed from the plasma only by convection. Barrera and coworkers24 showed that cytokine binding to the membrane may be an additional mechanism, which could also explain the paradoxic lack of correlation between cytokine reduction and ultrafiltrate volume found by others.6 The two filter membranes we used demonstrate some differences in their ability to eliminate cytokines. PAF was more effective lowering IL-10 and TCC plasma levels, whereas PSF was more effective lowering IL-6 and showed superior filtration quantities of TNF in the ultrafiltrate. However, filtration of IL-10, TCC, and lactoferrin was uniformly poor, as suggested by their low concentrations in the ultrafiltrate and their low ultrafiltrate/plasma ratio. Other studies with different filters and ultrafiltration methods have also found elimination of these inflammatory markers difficult, and it has been hypothesized that their larger molecule weights inhibit efficient filtration because their levels in the ultrafiltrate have been uniformly low in most studies,6,9,13,15 irrespective of the ultrafiltration method used. TNF was the only cytokine that was filtered to a larger extent, as shown by the much higher ultrafiltrate/plasma ratios and the large amounts of TNF in the ultrafiltrate. TNF was significantly better filtered with PSF than PAF, with significant differences in its concentration in the ultrafiltrate. TNF has been found to be effectively filtered with ultrafiltration by others as well,6,13,15 with PSF6,15,25 but also with other filter types, such as polynitril.4,17 Although filtered in larger quantities with PSF, however, plasma TNF levels did not significantly differ from those measured with PAF. This finding shows that the PSF may not be superior to the PAF to such a degree as to produce measurable differences in plasma TNF levels. Others have used PSF6,15,25 and PAF6,13,15 as well, and also different filters such as polynitril,4,17 but no one has compared one filter with another directly (eg, PSF vs PAF filters). Their results are quite comparable with ours concerning performance of individual filter types. Our comparison, however, shows a slightly superior profile of inflammatory mediator filtration of PSF compared to PAF filters, with better elimination of proinflammatory mediators such as TNF while anti-inflammatory mediators such as IL-10 are being withheld in the circulation, because a positive effect of ultrafiltration by elimination of cytokines depends on the balance between proinflammatory and anti-inflammatory cytokine levels after ultrafiltration.22
Although the difference was not statistically significant, ultrafiltration volume was smaller with MUF than with CUF in our study, in contrast to the findings of others.3,9 This reflects our practice of prolonging CUF for the whole phase of rewarming to maximize its potential benefits concerning water and cytokine elimination. With MUF, however, duration of filtration was limited to one to two cycles of the total circulating blood volume passing across the filter to keep the potentially hemodynamically unstable phase of filtration as short as possible. MUF was therefore limited to 20 minutes. Furthermore, with MUF the total volume accessible to filtration consisted of only the patient volume and was therefore much smaller than with CUF, during which patient plus CPB volume was being filtered. Nevertheless, with both methods it was always possible to remove at least the whole priming volume and reach excellent hemoconcentration, as demonstrated by an important rise in hematocrit in all groups.
Overall, our results seem to have been more influenced by the filter type used than by the ultrafiltration method applied, although differences were small. This finding puts the ongoing discussion on which ultrafiltration method may be the most effective into a new perspective and emphasizes the importance of the choice of the filter type and the need for taking it into consideration during the interpretation of study results. The power of this study may be limited by the small groups, although other authors have also studied effects of ultrafiltration with groups of comparable size.4-6,8,11,13,15,18,19 We decided to limit testing to the two filter types and ultrafiltration methods routinely in use at our institution. The presented results may not be directly comparable with those of others because of differences in the methods of ultrafiltration performed in this study. In particular, MUF was not performed exactly the same way as proposed by Elliott and associates.9 Although our method of MUF may not allow salvage of volume from the bypass circuit and may therefore require greater transfusion volumes of blood product, we do not think that these differences influence filter performance or cytokine elimination. The study may be further limited in not having measured the remaining potentially important inflammatory mediators, such as C3a, C5a, IL-1RA, and IL-8, or the activation of leukocytes by the granulocyte surface marker CD177, which might have shown somewhat different results. However, we chose the most important mediators from the interleukin, complement, and leukocyte systems with known effects on the inflammatory response and clinical parameters. There is to our knowledge currently no other study available that has directly compared different ultrafiltration methods and filter types in a prospectively randomized fashion. This study demonstrates that the contribution of the filter type to cytokine elimination obtained by ultrafiltration is not negligible and should be taken into consideration when interpreting study results.
Conclusions
In summary, the CUF with PSF combination (group C) was found to best eliminate IL-6, with no significant increase during filtration, the lowest IL-6 plasma concentrations directly after filtration, and the highest ultrafiltrate/plasma ratio. Concerning IL-10, PSF, perhaps combined with CUF, may best retain IL-10. We found TNF to be best lowered after MUF, and the largest amount in the ultrafiltrate was seen after MUF with PSF (group D), suggesting that TNF is most efficiently removed by this combination. TCC was found to be best lowered after the use of PAF and showed relatively large amounts in the ultrafiltrate after CUF with PAF (group A) but also after MUF with PSF. Should elimination of TCC be desired, PAF should not be combined with MUF, since no TCC at all was found in the ultrafiltrate after MUF with PAF (group B). Concerning lactoferrin, we found it to rise most significantly after the use of CUF with PAF (group A) and to be poorly filtered with very low concentrations in the ultrafiltate of all groups. We therefore think that the combinations we chose, especially CUF with PAF, were not suitable to eliminate lactoferrin. Taken together our results suggest that PSF is advantageous for the elimination of both IL-6 (combined with CUF) and TNF (combined with MUF) with preservation of IL-10 (combined with CUF). On the other hand, one should avoid PAF combined with MUF if TCC is the target and PAF combined with CUF for lactoferrin to be efficiently removed. Therefore the combination of CUF and MUF with a PSF may currently be the most effective strategy to remove inflammatory mediators in pediatric cardiac surgery with CPB.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
Y. Banz, R. Rieben, C. Zobrist, P. Meier, S. Shaw, J. Lanz, T. Carrel, and P. Berdat Addition of dextran sulfate to blood cardioplegia attenuates reperfusion injury in a porcine model of cardiopulmonary bypass Eur. J. Cardiothorac. Surg., September 1, 2008; 34(3): 653 - 660. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Yoshimura, Y. Oshima, M. Yoshida, H. Murakami, H. Matsuhisa, and M. Yamaguchi Continuous Hemodiafiltration During Cardiopulmonary Bypass in Infants Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 376 - 380. [Abstract] [Full Text] [PDF] |
||||
![]() |
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al. Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G Raja, S. Yousufuddin, F. Rasool, A. Nubi, M. Danton, and J. Pollock Impact of modified ultrafiltration on morbidity after pediatric cardiac surgery. Asian Cardiovasc Thorac Ann, August 1, 2006; 14(4): 341 - 350. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Brancaccio, E. Villa, E. Girolami, G. Michielon, C. Feltri, E. Mazzera, D. Costa, G. Isacchi, E. Iannace, A. Amodeo, et al. Inflammatory cytokines in pediatric cardiac surgery and variable effect of the hemofiltration process Perfusion, September 1, 2005; 20(5): 263 - 268. [Abstract] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |