|
|
||||||||
J Thorac Cardiovasc Surg 2005;129:1301-1308
© 2005 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease |
University of British Columbia, Vancouver, British Columbia, Canada.
Read at the Twenty-ninth Annual Meeting of The Western Thoracic Surgical Association, Carlsbad, Calif, June 1821, 2003.
Received for publication June 17, 2003; revisions received September 8, 2004; accepted for publication September 22, 2004. * Address for reprints: W. R. Eric Jamieson, MD, 486 Burrard Building, St Pauls Hospital, 1081 Burrard St, Vancouver, BC V6Z 1Y6, Canada. (Email: wrej{at}interchange.ubc.ca).
| Abstract |
|---|
|
|
|---|
METHODS: Between 1982 and 1998, a total of 959 bioprostheses were implanted in 943 patients, and a total of 961 mechanical prostheses were implanted in 839 patients. Total follow-ups were 5730 years for bioprostheses and 5271 years for mechanical prostheses. Eight variables were considered as predictors of risk for the composites of valve-related complications.
RESULTS: The linearized occurrence rates for valve-related reoperation were 3.7 events/100 patient-years for bioprostheses and 0.5 events/100 patient-years for mechanical prostheses (P < .001), with all age groups differentiated except older than 70 years. Valve-related morbidity was undifferentiated for bioprostheses and mechanical prostheses. Valve-related mortalities were 1.7 events/100 patient-years for bioprostheses and 0.7 events/100 patient-years for mechanical prostheses (P < .001). Predictors of valve-related reoperation were age and valve type. The only predictor of valve-related morbidity was age, whereas age and valve type were predictors for valve-related mortality. Actual freedom from valve-related reoperation favored mechanical prostheses in all age groups except older than 70 years (91.7% ± 2.0% for bioprostheses at 15 years and 96.7% ± 1.5% at 12 years for mechanical prostheses). Actual freedom from valve-related morbidity was not different between bioprostheses and mechanical prostheses. Actual freedom from valve-related mortality favored mechanical prostheses in all groups except older than 70 years.
CONCLUSION: Comparative evaluation gives high priority in mitral valve replacement for mechanical prostheses relative to bioprostheses for freedom from valve-related reoperation and valve-related mortality but not valve-related morbidity. Freedom from valve-related reoperation and valve-related mortality favors mechanical prostheses for all age groups except older than 70 years. Valve-related morbidity, due to neurologic or functional impairments, does not differentiate between bioprostheses and mechanical prostheses.
| Methods |
|---|
|
|
|---|
During the 17-year implantation period, the bioprosthesis types and numbers of implants were as follows: Carpentier-Edwards SAV (Edwards Lifesciences, Irvine, Calif; n = 857), Carpentier-Edwards PERIMOUNT (Edwards Lifesciences; n = 33), and Medtronic Mosaic (Medtronic, Inc, Minneapolis, Minn; n = 53), all second and third generation porcine bioprostheses. During this period the mechanical prostheses were as follows: St Jude Medical (St Jude Medical Inc, Minneapolis, Minn; n = 471) and CarboMedics (Sorin CarboMedics Inc, Austin, Tex, n = 313). The overall valve sizes at the initial procedure were 28.4 ± 2.2 mm for bioprostheses and 28.2 ± 2.3 mm for mechanical prostheses (P = .042).
Follow-up Procedure
The patients were followed up periodically throughout the observation period, with the closing interval in the year 2000 to 2001. The patients were evaluated by telephone interviews, and health records and consultations were evaluated when appropriate. The documentation on reoperative procedures was fully reviewed. The vital statistics death registry was used to ensure completeness of mortality data.
Study End Points
The three primary end points were valve-related mortality (inclusive of reoperative mortality), valve-related morbidity, and valve-related reoperation, as defined by "Guidelines for Reporting Morbidity and Mortality After Cardiac Valvular Operations" from the The Society of Thoracic Surgeons, The American Association for Thoracic Surgery, and European Association for Cardio-Thoracic Surgeons.7 Valve-related mortality included death caused by structural valve deterioration, nonstructural dysfunction, thrombosis, thromboembolism, hemorrhage, or prosthetic valve endocarditis and death related to reoperation for a valve-related complication. Valve-related mortality was inclusive of sudden unexplained, unexpected deaths. Valve-related reoperation was reoperation for any valve-related complication. Valve-related morbidity was considered, for this study, as permanent valve-related impairment as a result of permanent neurologic or other functional deficit caused by structural valve deterioration, nonstructural valve dysfunction, valve thrombosis, thrombotic embolism, bleeding, prosthetic valve endocarditis, or reoperation.
All valve-related complications were used to calculate the composites of valve-related mortality, valve-related reoperation, and valve-related morbidity, with these composites being attributed to the particular valve type (either bioprosthesis or mechanical prosthesis). When patients had a bioprosthesis explanted and a mechanical prosthesis implanted or vice versa, they were censored from the former group and entered into the latter group. Operative mortality (30-day mortality) was attributed to the explanted prosthesis and classified as valve-related mortality. It is for this reason the study did not evaluate patient survival, because a portion of the patients were in both the bioprosthesis and mechanical prosthesis arms of the study.
The variables considered as predictors of risk for the composites of valve-related complications were prosthesis type, age (continuous variable), age group (categoric variable), sex, prosthesis size, and concomitant CABG. All patients undergoing initial cardiac operations between 1982 and 1998, as well as reoperation in 1999, 2000, or 2001, were included in the analysis.
Statistical Analysis
Differences in baseline characteristics between the two groups were compared with the t test for continuous variables and
2 for categoric variables; no adjustment for multiple comparisons was made. The composites of valve-related complications were calculated for freedom from the complications composite with the Kaplan-Meier actuarial methodology and compared by the log-rank statistic. The actual freedom or cumulative incidence was determined by the modified Kaplan-Meier methodology of Grunkemeier and colleagues.811 The composites of complications were also evaluated as linearized occurrence rates as events/100 patient-years, with comparisons made with the log likelihood ratio statistic. Linearized occurrence rates are not recommended for evaluation of structural valve deterioration reoperation because of lack of constant hazard with time but an advancing hazard with time. The Weibull distribution curve is the appropriate representation of structural valve deterioration and structural valve deterioration reoperation. Linearized occurrence rates were used in this study to depict valve-related reoperation, because valve-related reoperation was inclusive of all causes of valve-related reoperation: prosthetic valve endocarditis, nonstructural dysfunction (periprosthetic leak), and prosthesis thrombosis, as well as structural valve deterioration. The predictors of the complications composites were determined by univariate analysis and multiple Cox hazard regression analysis.
| Results |
|---|
|
|
|---|
|
The predictors of valve-related composites of complications are presented in Table 2. The predictors of valve-related reoperation were age and prosthesis type. The mean age at implantation of patients who underwent a reoperation (n = 240) was 56.0 ± 12.9 years; that for those who did not (n = 1680) was 63.4 ± 11.7 years (P < .001). The hazard ratio (HR) was 0.98 (95% confidence interval 0.970.99, P = .0001). Reoperation for prosthesis type was performed in 2.7% of mechanical prosthesis cases (n = 26) and 22.2% of bioprosthesis cases (n = 214, P = .001). The HR of valve type for valve-related reoperation was 0.19 (95% confidence interval 0.130.29, P < .001, bioprostheses greater than mechanical prostheses). Among those who underwent valve-related reoperation, concomitant CABG was performed at initial surgery or valve-related reoperation in 8.6% (n = 61/710) and not in 14.8% (n = 179/1210, P < .0001). The HR for concomitant CABG was 1.2 (95% confidence interval 0.91.7, P = .1278).
|
The freedom (± SD) from composites of valve-related complications are detailed for actual and actuarial freedom to 15 years from valve-related reoperation, valve-related morbidity, and valve-related mortality in Figures 1 through 6 for age groups 61 through 70 and older than 70 years.
|
The actuarial freedom from valve-related morbidity for all age groups was undifferentiated between bioprostheses and mechanical prostheses (P not significant). The actual freedom from valve-related morbidity was also undifferentiated for all age groups between bioprostheses and mechanical prostheses.
The actuarial freedom from valve-related mortality was only different for age 51 through 60 years, at 75.4% ± 8.3% for bioprostheses and 87.5% ± 8.7% for mechanical prostheses. There were identifiable trends in actual freedom in favor of mechanical prostheses relative to bioprostheses for age groups 41 through 50, 51 through 60, 61 through 70, and older than 70 years.
The actual and actuarial freedoms from each of the composites for age groups 61 through 70 years and older than 70 years are demonstrated in Figures 1 through 6. The actual freedoms from valve-related reoperation at 15 years for the age group 61 through 70 years were 75.2% ± 2.6% for bioprostheses and 95.6% ± 1.8% at 12 years for mechanical prostheses (Figure 1). The actual freedoms from valve-related reoperation for the age group older than 70 years were 91.7% ± 2.0% for bioprostheses at 15 years and 97.1% ± 1.5% at 11 years for mechanical prostheses (Figure 2).
|
|
|
|
There were 214 reoperations in the bioprosthesis group and 26 in the mechanical prosthesis group. The distribution by cause of first events was nonstructural dysfunction for 15 bioprostheses and 12 mechanical prostheses, prosthetic valve endocarditis for 14 bioprostheses and 2 mechanical prostheses, structural valve deterioration for 180 bioprostheses (n = 53 for 5160 years, n = 62 for 6170 years, n = 11 for >70 years) and 0 mechanical prostheses, and thrombosis for 5 bioprostheses and 12 mechanical prostheses. There were 97 valve-related deaths in the bioprosthesis group and 36 in the mechanical prosthesis group. The distribution by cause of first events was bleeding for 9 bioprostheses and 14 mechanical prostheses, nonstructural dysfunction for 7 bioprostheses and 2 mechanical prostheses, prosthetic valve endocarditis for 9 bioprostheses and 4 mechanical prostheses, structural valve deterioration for 34 bioprostheses (n = 20 for 6170 years, n = 9 for >70 years) and 0 mechanical prostheses, thromboembolism for 28 bioprostheses and 11 mechanical prostheses, thrombosis for 3 bioprostheses and 3 mechanical prostheses, and sudden unexpected death for 7 bioprostheses and 2 mechanical prostheses.
| Discussion |
|---|
|
|
|---|
There have been two large randomized trials comparing the performance of bioprostheses and mechanical prostheses.15 The United States Veterans Affairs randomized aortic and mitral implantations to the Björk-Shiley spherical disk mechanical prosthesis or the Hancock porcine bioprosthesis. The Veterans Affairs study has produced three publications, with the final report in 2000 documenting their 15-year experience.13 The principal long-term findings are as follows: mechanical valves resulted in a lower mortality and lower reoperation rate for aortic valve replacement; the mortality for mitral valve replacement was similar between prosthetic valve types; primary tissue failure after both aortic and mitral valve replacement occurred more frequently with a bioprosthetic valve, especially in patients less than 65 years at implantation; use of the bioprosthetic valve resulted in a lower bleeding rate; and there were no differences between the valve types with regard to other valve-related complications, including thromboembolism and all complications.
The other randomized trial between bioprostheses and a mechanical valve, the Edinburgh trial, was reported on in 1991 and 2003.4,5 At 12 years, the study indicated a trend toward better survival with the mechanical valve. The 20-year evaluation revealed no difference in survival between the mechanical prosthesis and bioprosthesis populations. The study considered combined death and reoperation as end points and confirmed that patients with mechanical prostheses had improved survival with the original prosthesis intact. This difference became apparent after 8 to 10 years for mitral valve replacement and after 12 to 14 years for aortic valve replacement. Major bleeding was more common with mechanical prostheses, but there was no difference in major embolism or endocarditis. Other studies have identified similar survival trends between bioprostheses and mechanical prostheses.12,13 Demirag and investigators14 found no difference in survival and reoperation at 10 years in their study evaluating the Biocor porcine bioprosthesis and St Jude Medical mechanical prosthesis in the mitral position. In a 20-year comparison study in an elderly population, bioprostheses did not offer a survival advantage relative to mechanical valves.15 That study did determine that anticoagulant-related mortality and morbidity were higher in patients with mechanical valves. Kassai and colleagues16 also evaluated survival in a meta-analysis of randomized clinical trials comparing bioprostheses and mechanical prostheses and found no significant influence. Kawachi and coworkers17 compared the two prosthesis types in the mitral position and also failed to find any survival benefit. That study also reported for bioprostheses in the mitral position only a small benefit in antithrombogenesis but a prominent disadvantage in altered durability necessitating reoperation.
Jamieson and colleagues18,19 have provided considerable documentation supporting the indications for bioprostheses and mechanical prostheses. Bioprostheses are recommended for aortic valve replacement in patients older than 65 years and for mitral valve replacement in patients older than 70 years.6,18,19 Mechanical prostheses are the predominant choice of prosthesis type other than for these age groups.
This study assessed the composites of valve-related complicationsreoperation, morbidity (permanent impairment), and mortalityby both actuarial and actual methodologies. Jamieson and colleagues6 previously reported on valve-related reoperation and valve-related mortality in a porcine bioprosthesis population. The actual freedom for mitral valve replacement at 15 years from valve-related mortality in the age group 61 through 70 years was 79.5% (actuarial 59.5%), and in the age group older than 70 years it was 82.0% (actuarial 26.1%). The actual freedom at 15 years from valve-related reoperation in the age group 61 through 70 years was 71.0% (actuarial 32.6%), and in the age group older than 70 years, it was 93.3% (actuarial 83.4%). Those results are not appreciably different from those in this study.
This study compared the performance of bioprostheses and mechanical prostheses to 15 years. Actual freedoms from valve-related reoperation at 15 years for bioprostheses were less than 50% for patients younger than or equal to 60 years, 75% for those aged 61 through 70 years, and 92% for those older than 70 years. Mechanical prostheses had a greater than 94% actual freedom from valve-related reoperation in all age groups at 12 to 15 years. There was no differentiation between bioprostheses and mechanical prostheses in freedom from valve-related morbidity (permanent neurologic or functional impairment) for all age groups. The freedom from valve-related mortality was extended for all age groups (88%-99% at 1215 years) for mechanical prostheses, yet relatively stable for all age groups for bioprostheses (81%-88% at 15 years). There are no comparable studies in the literature except the previously quoted results for bioprostheses from our institution.6,18
This study captured all valve-related morbidity and mortality events for both mechanical prostheses and bioprostheses by censoring patients 31 days after reoperation if the valve type changed and the patients entered into the new valve type group. If the valve type did not change at reoperation, the patients remained in the original groups. This methodology of patient classification precluded the determination of patient survival for mechanical prostheses and bioprostheses, because the patients with successful reoperations were in both arms of the study. The major limitation of the study is that the follow-up of the mechanical prostheses did not afford acceptable numbers of patients at risk between 12 and 15 years.
This comparative evaluation suggests a priority for mechanical prostheses relative to bioprostheses with regard to freedom from valve-related reoperation and valve-related mortality, but not from freedom from valve-related morbidity because of neurologic or functional impairment. The recommendation from this center for mitral valve replacement, as documented in previous publications, was to implant bioprostheses in patients older than 70 years and in selected patients older than 60 years because of life-limiting comorbidities. These recommendations remain unchanged after this comparative study. This study, as do our previous studies, provides evidence favoring bioprosthesis use in patients older than 70 years because of the freedom from reoperation. Our recent publication20 documented excellent reoperative mortality for structural valve deterioration, with the risk factors for reoperative mortality predominantly emergency status and advanced New York Heart Association functional class IV. An excellent patient surveillance system would avoid high risk reoperative surgery and afford greater freedom from valve-related mortality. The choice of prosthesis for mitral valve replacement goes beyond the consideration of composites of complications that cause reoperation, permanent and functional impairment, or mortality to influential factors inclusive of long-term care with anticoagulation and the risk of nonmorbid thromboembolic events and hemorrhagic events. As stated, the design of this comparative study with crossover of prosthesis type at reoperation to the alternative type precluded the opportunity to evaluate patient survival between bioprostheses and mechanical prostheses.
| Discussion |
|---|
|
|
|---|
Your study proposes that valve-related reoperation favors mechanical prostheses for all but patients older than 70 years, that valve-related mortality favors mechanical relative to bioprosthetic valves for patients 70 years of age and younger, and that valve-related morbidity is the same for mechanical and bioprosthetic valves in all age groups. You conclude that patients 70 years of age and younger requiring mitral valve replacement should receive a mechanical valve and that for those older than 70 there is no advantage of bioprostheses relative to mechanical prostheses.
I have several concerns and questions about this report. Your definition of valve-related morbidity excluded nonpermanent events. You have already elaborated on that to some extent, but I did note that in a previous study of your own mitral mechanical replacements you reported a thromboembolic event rate of 5.5 events/100 patient-years and a hemorrhagic complication rate of 1.5 events/100 patient-years. That is opposed to the 0.57 events/100 patient-years valve-related morbidity that you report in this report. Did you exclude peripheral emboli that were successfully treated surgically or hemorrhage that required transfusion or a thrombosed valve that was successfully treated with thrombolytic therapy? Do you believe that such events should be considered when selecting a prosthesis for a given patient?
Dr Jamieson. You are right, Dr Sintek. In that group of patients, we did have an incidence of thromboembolism of 5.0 events/100 patient-years, and that included minor events, major events, RIND (reversible ischemic neurologic deficits), and thrombosis. For this particular study, we went on the understanding that the patients were really concerned whether they would die from the valve, would have a reoperation, or would have permanent impairment. We did alter that definition, and we do describe what we did here. There is no question that the nonmorbid events are still important to the patient, but we did try and differentiate here as to whether or not the patient had a permanent neurologic impairment in particular.
Dr Sintek. I am concerned about the shorter follow-up for your mechanical valve population. In fact, I am not sure that there are enough patients older than 70 years at riskeven at 10 years, there were only 7 patientsto come to a valid conclusion in comparison with the bioprosthetic group.
Dr Jamieson. Yes, I do agree with you. We commenced this follow-up about 3 years ago, and we are concerned about the lesser number of patients at risk at the advanced years in the mechanical prosthesis population. It is conceivable even today that if we went back and followed those mechanical valves again, we would add greater numbers at the extended years. I think that is part of this whole work in process. That is important, and I take your criticism as valid.
Dr Sintek. You found no difference in the need for reoperation in patients undergoing concomitant CABG with mitral valve replacement, although previous CABG was a predictor for valve-related reoperation. Could you elaborate on this?
Dr Jamieson. Ill answer the second question first. Those patients who had previous CABG obviously have an anticipated reduced life expectancy because of this comorbid disease. Consequently, because of reduced life expectancy, they have a reduced potential for reoperation. The other important part of this though, is that among those patients for whom we did concomitant CABG at the time of reoperation, that was not a factor. This is probably related to a study we presented at the American Heart Association meeting in November, in which we found that in the last 7 years we reduced our valve-related mitral mortality to 3.4%, among those with concomitant coronary bypass, to 2.8%, so these are influential factors in here that are coming through. Concomitant coronary bypass is not a predictor because of our last 8-year experience.
Dr Sintek. This is a comparative study, not randomized. Did cardiac rhythm play a role in selecting a prosthesis for a given patient? And could you share with us your anticoagulation protocol for both bioprosthetic and mechanical valves in the mitral position?
Dr Jamieson. We looked at rhythm as a factor here, and it did not come out in univariate analysis as being a predictor. As far as anticoagulation goes, the majority (and I just say the majority because there are 15 surgeons in this group) do use anticoagulation early and for at least 6 weeks in those patients who are in sinus rhythm and do not have other extenuating factors as risk factors for venous stasis in the atrium, and those patients would be anticoagulated and then switched to aspirin if they had a bioprosthesis and obviously continued on if the prosthesis was mechanical. The patients with mechanical prostheses were always anticoagulated early. In recent years, we have also been using low-dose heparin, and I might share with you some information from the AVERT (Artificial Valve Endocarditis Reduction Trial) trial that patients who were on heparin early postoperatively also had a reduced incidence of late thromboembolic events. This is a factor not yet fully explored.
Dr Sintek. Last, applying the lessons learned from your study, what type valve would you implant in a 69-year-old man in sinus rhythm requiring mitral valve replacement and CABG?
Dr Jamieson. Well, there are certainly factors here that are not readily apparent. You have to look at the bioprosthesis that you are using. A large group of these patients were implanted with Carpentier-Edwards supra-annular valves in the mitral position, and we found a few years ago and actually presented at the Western Thoracic Surgical Association meeting that the supra-annular porcine valve did not fare as well as the Carpentier-Edwards PERIMOUNT pericardial valve. We have now a 6-year experience with the Medtronic Mosaic. The other factor to be considered, coming out of the experience in Sweden, and this perhaps is going to be brought out next weekend at the Society for Heart Valve Disease, is that those porcine valves that are formulated as a tricomposite configuration with three separate leaflets appear to have extended durability in the mitral position. So looking at those things and what is coming forward in the future and what will be available even in North America on a trial basis within a couple of months, I might certainly consider an advanced generation bioprosthesis for the patient in sinus rhythm undergoing concomitant CABG.
|
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. Gudbjartsson, T. Absi, and S. Aranki Mitral Valve Replacement Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068. [Full Text] |
||||
![]() |
M. Ruel, V. Chan, P. Bedard, A. Kulik, L. Ressler, B. K. Lam, F. D. Rubens, W. Goldstein, P. J. Hendry, R. G. Masters, et al. Very Long-Term Survival Implications of Heart Valve Replacement With Tissue Versus Mechanical Prostheses in Adults <60 Years of Age Circulation, September 11, 2007; 116(11_suppl): I-294 - I-300. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, P. Bedard, B-K. Lam, F. D. Rubens, P. J. Hendry, R. G. Masters, T. G. Mesana, and M. Ruel Mechanical versus bioprosthetic valve replacement in middle-aged patients. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 485 - 491. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Chan, W.R.E. Jamieson, E. Germann, F. Chan, R.T. Miyagishima, L.H. Burr, M.T. Janusz, H. Ling, and G.J. Fradet Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15 years after aortic valve replacement J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1267 - 1273. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |